LTMR27EFM Schneider Electric - Motor Management, TeSys T, motor controller, Ethernet/IP, Modbus/TCP, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240 VAC

Extended Description for LTMR27EFM Schneider Electric

LTMR27EFM Schneider Electric - TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor.,TeSys T manages most critical processes while reducing downtime and increasing productivity.,TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols.,TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range.,This controller is the central component in the motor management system.,The module manages the basic functions of the motor management system.,It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers.,It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions.,Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used.,This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay.,The current range of this controller is 1.35 to 27 amperes.,120 to 240 VAC is used to power this controller.,Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£335.26 Exc. VAT
£402.31 Inc. VAT

Main

Range TeSys
Product name TeSys T
Device short name LTMR
product or component type Motor controller
device application Equipment monitoring and control
Measurement current 1.35…27 A
[Us] rated supply voltage 100...240 V AC 50/60 Hz
current consumption 8...62.8 mA
Supply voltage limits 93.5…264 V AC
communication port protocol Modbus TCP/EtherNet/IP
Bus type Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs

Complementary

[Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1,690 V conforming to CSA C22.2 No 14,690 V conforming to UL 508
[Uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1,6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1,0.8 kV communication circuit conforming to EN/IEC 60947-4-1
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Associated fuse rating 4 A gG for output,0.5 A gG for control circuit
Protection type Phase unbalance,Earth-leakage protection,Thermal protection,Reverse polarity protection,Power factor variation,Overload,Load fluctuation,Locked rotor,Thermal overload protection,Phase failure,Overload (long time)
Network and machine diagnosis type Event recording,Trip context information,Phase fault and earth fault trip counters,Trip history information,Waiting time after overload tripping,Fault recording,Remaining operating time before overload tripping,Starting current and time,Motor control command recording,Running hours counter/operating time
Logic input number 6
Input current 3.1 mA at 100 V,7.5 mA at 240 V
Current state 0 guaranteed Logic input: 0...40 V and <= 15 mA for 25 ms
Current state 1 guaranteed Logic input: 79...264 V and >= 2 mA for 25 ms
maximum output switching frequency 2 Hz
Load current 5 A at 250 V AC for logic output,5 A at 30 V DC for logic output
Permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output),30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Maximum operating rate 1800 cyc/h
Contacts type and composition 1 NO + 1 NC fault signal,3 NO
Metering type Average current Iavg,Phase current I1, I2, I3 RMS,Imbalance current,Earth-fault current,Temperature
Measurement accuracy 5...15 % earth fault current internal measurement,1 % voltage (100...830 V),3 % power factor,5 % earth fault current external measurement,+/- 30 min/year internal clock,0,02 temperature,1 % current,5 % active and reactive power
Overvoltage category III
Connection pitch 5.08 mm
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end,Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end,Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end,Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
Tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
Pollution degree 3
Electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2,Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3,Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4,Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4,Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11,Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6,Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5,Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5,Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5,Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5,Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5,Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5,Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width 91 mm
Height 61 mm
Depth 122.5 mm
net weight 0.53 kg
Web services Web server
compatibility code LTMR

Environment

Standards IACS E10,UL 508,IEC 60947-4-1,EN 60947-4-1,CSA C22.2 No 14
Product certifications EAC,DNV,BV,C-Tick,CCC,ABS,RINA,RMRoS,CSA,NOM,LROS (Lloyds register of shipping),UL,KERI,GL,ATEX
Protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30,48 h conforming to EN/IEC 60070-2-11,TH conforming to EN/IEC 60068
Fire resistance 650 °C conforming to EN/IEC 60695-2-12,960 °C conforming to UL 94
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…80 °C
Operating altitude <= 2000 m without derating
Mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6,Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6,Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection IP20

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.2 cm
Package 1 Width 10.0 cm
Package 1 Length 13.5 cm
Package 1 Weight 530.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 10
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 5.615 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible