Description for LUCMT1BL Schneider Electric

LUCMT1BL Schneider Electric - Multifunction control unit, TeSys U, 0.35-1.05A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24V DC

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£456.47 Exc. VAT
£547.76 Inc. VAT

Main

Range TeSys
range of product TeSys Ultra
Device short name LUCM
product or component type Multifunction control unit
device application Motor control,Motor protection
Product specific application Most sophisticated control and protection requirements, with display
main function available Overload, no-load running,Protection against phase failure and phase imbalance,Protection against overload and short-circuit,Manual or automatic reset,Earth fault protection,Log function,Differentiation of thermal overload and magnetic fault,Protection function alarm,Monitoring function, indication of main motor parameters
Product compatibility Power base LUTM
Network frequency 40...60 Hz
Load type 3-phase motor - cooling: self-cooled - setting factory setting,3-phase motor - cooling: self-cooled, force cooled - setting settable,Single-phase motor - cooling: self-cooled, force cooled - setting settable
Utilisation category AC-41,AC-44,AC-43
rated motor current adjustment range 0.35…1.05 A
Thermal overload class Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to IEC 60947-6-2,Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to UL 508
Tripping threshold 14.2 x Ir +/- 20 %
Phase failure sensitivity Yes
[Uc] control circuit voltage 24 V DC

Complementary

Control circuit voltage limits 20...28 V for DC circuit 24 V in operation,14.5 V for DC circuit 24 V drop-out
Typical current consumption 130 mA at 24 V DC I maximum while closing,60 mA at 24 V DC I rms sealed
Heat dissipation 2 W for control circuit
Operating time 35 ms opening for control circuit,70 ms closing for control circuit
Physical interface RS485 multidrop - connector(s): RJ45 - location: front panel - communication protocol: Modbus RTU 19200 bit/s
Return time <= 200 ms
Messages display capacity 2 lines of 12 characters - display LCD - English - accuracy +/- 5 % - resolution 1 % of Ir,2 lines of 12 characters - display LCD - French - accuracy +/- 5 % - resolution 1 % of Ir,2 lines of 12 characters - display LCD - German - accuracy +/- 5 % - resolution 1 % of Ir,2 lines of 12 characters - display LCD - Italian - accuracy +/- 5 % - resolution 1 % of Ir,2 lines of 12 characters - display LCD - Spanish - accuracy +/- 5 % - resolution 1 % of Ir
Reset Automatic reset - setting: setting range,Manual - setting: factory setting,Manual - setting: setting range,Remote reset - setting: setting range
Time before reset 1…1000 s - reset manual or automatic reset - setting settable,120 s - reset manual - setting factory setting
User language English - setting factory setting,English, French, German, Italian, Spanish - setting settable
Information displayed Average current (factory setting),Average current (settable),Cause of last 5 faults (settable),Current in phase (settable),Earth leakage current (settable),Phase imbalance (settable),Thermal state of motor (settable)
Standards EN 60947-6-2,IEC 60947-6-2,UL 508,CSA C22.2 No 14
Product certifications UL,CSA
[Ui] rated insulation voltage 250 V conforming to IEC 60947-6-2,250 V conforming to UL 60947-4-1,250 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 60947-6-2
Fixing mode Plug-in (front face)
Width 45 mm
Height 66 mm
Depth 60 mm
net weight 0.175 kg
compatibility code LUCM

Environment

IP degree of protection IP20 front panel and wired terminals conforming to IEC 60947-1,IP20 other faces conforming to IEC 60947-1,IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment TH conforming to IEC 60068
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 2000 m
Fire resistance 960 °C parts supporting live components conforming to IEC 60695-2-12,650 °C conforming to IEC 60695-2-12
Shock resistance 10 gn power poles open conforming to IEC 60068-2-27,15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6,4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance to electrostatic discharge 8 kV level 3 in open air conforming to IEC 61000-4-2,8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance to radiated fields 10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients 2 kV class 3 serial link conforming to IEC 61000-4-4,4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity to radioelectric fields 10 V conforming to IEC 61000-4-6
Immunity to microbreaks 3 ms
Immunity to voltage dips 70 % / 500 ms conforming to IEC 61000-4-11

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.000 cm
Package 1 Width 10.200 cm
Package 1 Length 5.500 cm
Package 1 Weight 171.900 g
Unit Type of Package 2 S02
Number of Units in Package 2 23
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 4.276 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible