This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LV480506

LV480506 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LV480506 Schneider Electric

LV480506 Schneider Electric - Switch disconnector fuse, FuPact INFD400, 400 A, 3 poles 3F, fuse type DIN 0/1/2, front control

Extended Description for LV480506 Schneider Electric

LV480506 Schneider Electric - This is a fixed front-connected fuse switch disconnector (3 poles and 3 fuse-links) with front control.,It is dedicated to buildings, infrastructure and Industrial plants.,It protects against short-circuits and overloads on distribution circuits.,It provides an isolation with positive contact indication when the switch is in the open position thanks to it double breaking technology.,Fupact INF allows on-load switching of circuits with fast opening and closing.,It is compatible with DIN NH (0,1,2) fuse-links.,The rated operational current is 400A AC22A/AC23A and the operational voltage is 690 VAC or 750 VDC.,It complies with IEC 60947-1 and IEC 60947-3 standards.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£1,071.43 Exc. VAT
£1,285.72 Inc. VAT

Main

range of product INF200...800
Range FuPact
Product name Fupact INF
Device short name INFD400
product or component type Switch-disconnector-fuse
device application Protection
Poles description 3P
Protected poles description 3f
Fuse type DIN
Fuse size NH2,NH1,NH0
Network type AC,DC
Network frequency 50/60 Hz

Complementary

Control type Operating shaft (without handle)
Rotary handle mounting location Front
mounting mode Fixed
Mounting support Mounting plate
[Ie] rated operational current AC-22A: 400 A at 220/240 V AC 50/60 Hz,AC-22A: 400 A at 380/415 V AC 50/60 Hz,AC-22A: 400 A at 440/480 V AC 50/60 Hz,AC-22A: 400 A at 500/525 V AC 50/60 Hz,AC-22A: 400 A at 660/690 V AC 50/60 Hz,AC-23A: 400 A at 220/240 V AC 50/60 Hz,AC-23A: 400 A at 380/415 V AC 50/60 Hz,AC-23A: 400 A at 440/480 V AC 50/60 Hz,AC-23A: 400 A at 500/525 V AC 50/60 Hz,AC-23A: 400 A at 660/690 V AC 50/60 Hz,DC-22A: 400 A at 125 V DC (2 poles in series),DC-23A: 400 A at 125 V DC (2 poles in series),AC-22A: 400 A at 480 V AC 50/60 Hz conforming to NEMA,AC-23A: 400 A at 480 V AC 50/60 Hz conforming to NEMA,DC-22A: 400 A at 250 V DC (3 poles in series),DC-23A: 400 A at 250 V DC (3 poles in series)
[Ith] conventional free air thermal current 400 A ( 40 °C ) power dissipation per fuse: 45 W vertical,283 A ( 70 °C ) horizontal,283 A ( 70 °C ) vertical,302 A ( 65 °C ) horizontal,302 A ( 65 °C ) vertical,321 A ( 60 °C ) horizontal,321 A ( 60 °C ) vertical,338 A ( 55 °C ) horizontal,338 A ( 55 °C ) vertical,355 A ( 50 °C ) horizontal,355 A ( 50 °C ) vertical,370 A ( 45 °C ) horizontal,370 A ( 45 °C ) vertical,385 A ( 40 °C ) horizontal,400 A ( 35 °C ) horizontal
[Ithe] conventional enclosed thermal current 360 A at 40 °C, Power dissipation per fuse: 37 W (610 mm x 508 mm x 254 mm),400 A at 40 °C, Power dissipation per fuse: 30 W (610 mm x 508 mm x 254 mm)
Maximum power AC-23: 132 kW at 220/240 V AC 50/60 Hz,AC-23: 220 kW at 380/400 V AC 50/60 Hz,AC-23: 230 kW at 415 V AC 50/60 Hz,AC-23: 280 kW at 500/525 V AC 50/60 Hz,AC-23: 400 kW at 660/690 V AC 50/60 Hz
Rated duty Uninterrupted
[Ui] rated insulation voltage 1000 V AC 50/60 Hz,1000 V DC
[Uimp] rated impulse withstand voltage 12 kV
[Ue] rated operational voltage 690 V AC 50/60 Hz,1000 V AC 50/60 Hz AC-20,1000 V DC DC-20,750 V DC
[Im] rated making and breaking capacity Icm 220 kA at 500 V conforming to DIN (with fuse),Icn 100 kA at 500 V conforming to DIN (with fuse),Icm 176 kA at 415 V conforming to DIN (with fuse),Icm 176 kA at 690 V conforming to DIN (with fuse),Icn 80 kA at 415 V conforming to DIN (with fuse),Icn 80 kA at 690 V conforming to DIN (with fuse),Icm 48 kA at 690 V (without fuse),Icm 59 kA at 415 V (without fuse),Icm 63.5 kA at 500 V (without fuse)
Suitability for isolation Yes conforming to IEC 60947-1
Contact position indicator Yes
Contact operation Double-break

Environment

Mechanical durability 8000 cycles
Electrical durability AC-22A: 1000 cycles 500 V AC 50/60 Hz,AC-22A: 1000 cycles 690 V AC 50/60 Hz,AC-23A: 1000 cycles 500 V AC 50/60 Hz,AC-23A: 1000 cycles 690 V AC 50/60 Hz
[Icw] rated short-time withstand current 14 kA for 1 s,2.55 kA for 30 s,3.13 kA for 20 s,8.08 kA for 3 s
Design Horizontal design
Connections terminals Screw connection
Connections - terminals Screw connection M10 400 A
Tightening torque 30...44 N.m for terminal
Height 230 mm
Width 254 mm
Depth 193 mm
Standards EN/IEC 60947-3,EN/IEC 60947-1
IP degree of protection IP20 fuse compartment:
Pollution degree 3

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible