Description for METSEPM5110 Schneider Electric

METSEPM5110 Schneider Electric - PM5110 Meter, modbus, up to 15th H, 1DO 33 alarms

Extended Description for METSEPM5110 Schneider Electric

METSEPM5110 Schneider Electric - This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display.,The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle.,The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic.,The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC.,Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations.,The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz.,Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz.,Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support.,The meter also has one digital pulse output and 33 configurable alarms.,Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).

Free Delivery to UK Mainland on orders over £25

Manufacturer New

10 available
1 - 2 w.days
£320.42 Exc. VAT
£384.50 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£258.99 Exc. VAT
£310.79 Inc. VAT

Main

Range PowerLogic
Product name PowerLogic PM5000
Device short name PM5110
product or component type Power meter

Complementary

Power quality analysis up to the 15th harmonic
device application Power monitoring
Type of measurement Current,Voltage,Frequency,Power factor,Energy,Active and reactive power
supply voltage 90...450 V AC 45...65 Hz,100...300 V DC
Network frequency 50 Hz,60 Hz
[In] rated current 1 A,5 A
type of network 1P + N,3P + N,3P
Maximum power consumption in VA 11 VA at 415 V
Ride-through time 80 ms 120 V AC typical,100 ms 230 V AC typical,100 ms 415 V AC typical,50 ms 125 V DC typical
Display type Monochrome graphic LCD
Display resolution 128 x 128 pixels
Sampling rate 64 samples/cycle
Measurement current 50…8500 mA
Analogue input type Voltage (impedance 5 MOhm),Current (impedance <= 0.3 mOhm)
Measurement voltage 35…760 V AC 45...65 Hz between phases,20…440 V AC 45...65 Hz between phase and neutral
Frequency measurement range 45…65 Hz
Number of inputs 0
Measurement accuracy Active energy +/- 0.5 %,Reactive energy +/- 2 %,Active power +/- 0.5 %,Apparent power +/- 0.5 %,Frequency +/- 0.05 %,Power factor +/- 0.5,Current +/- 0.5 %,Voltage +/- 0.5 %,Apparent energy +/- 0.5 %,Reactive power +/- 2 %
Accuracy class Class 0.5S active energy conforming to IEC 62053-22
Number of outputs 1 digital
Communication port protocol Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V,JBUS
Communication port support RS485
Data recording Time stamping,Min/max of instantaneous values
Connections - terminals Voltage circuit: screw terminal block4,Control circuit: screw terminal block2,Current transformer: screw terminal block6,Input/output circuit: screw terminal block6,RS485 link: screw terminal block4
mounting mode Flush-mounted
Mounting support Framework
Standards UL 61010-1,EN 50470-3,EN 50470-1,IEC 62053-22:2020,IEC 60529,IEC 62053-24,IEC 61557-12:2015,IEC 62053-23:2020,IEC 62052-11:2020,IEC 62052-31:2015
Product certifications CE conforming to IEC 61010-1,CULus conforming to UL 61010-1
Width 96 mm
Depth 72 mm
Height 96 mm
net weight 380 g

Environment

Electromagnetic compatibility Voltage dips and interruptions immunity test class A conforming to IEC 61000-4-11,Limits for harmonic current emissions class A conforming to IEC 61000-3-2,Electrostatic discharge level 4 conforming to IEC 61000-4-2,Conducted RF disturbances level 3 conforming to IEC 61000-4-6,Magnetic field at power frequency level 4 conforming to IEC 61000-4-8,Conducted and radiated emissions - test level: 150 kHz...80 MHz class B conforming to EN 55022,Immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6,Electrical fast transient/burst immunity test conforming to IEC 61000-4-4,Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3,Surge immunity test class B conforming to IEC 61000-4-5,Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protection IP54 display: conforming to IEC 60529,IP30 rear: conforming to IEC 60529
Relative humidity 5…95 % at 50 °C non-condensing
Pollution degree 2
Ambient air temperature for operation -25…70 °C meter,-20…70 °C display,-25…-20 °C (with reduced performance) display
Ambient air temperature for storage -40…85 °C
Operating altitude 2000 m CAT III

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.467 cm
Package 1 Width 12.979 cm
Package 1 Length 12.544 cm
Package 1 Weight 449.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 12
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.19 kg
Unit Type of Package 3 P12
Number of Units in Package 3 288
Package 3 Height 105.0 cm
Package 3 Width 80.0 cm
Package 3 Length 120.0 cm
Package 3 Weight 206.4 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible