This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

METSEPM5760

METSEPM5760 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for METSEPM5760 Schneider Electric

METSEPM5760 Schneider Electric - PM5760 Meter, 2 ethernet, up to 63th H, 1,1M, wave+RCM, 4DI/2DO 52 alarms

Extended Description for METSEPM5760 Schneider Electric

METSEPM5760 Schneider Electric - This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display.,The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle.,The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic.,Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration.,This meter also feature the direct monitoring of neutral current, a residual current monitoring with ground current calculation plus an advanced waveform capture with sag and swell detection.,The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC.,Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations.,The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz.,Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz.,Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support.,The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway.,The meter also has four digital inputs with WAGES support and two digital outputs.,There are 52 configurable alarms and it supports eight tariff schedules.,Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£633.13 Exc. VAT
£759.76 Inc. VAT

Main

Range PowerLogic
Product name PowerLogic PM5000
Device short name PM5760
product or component type Power meter

Complementary

Power quality analysis up to the 63rd harmonic, waveform capture, voltage sag and swell detection, residual current monitoring
Metering type Measured neutral current,Calculated ground current,Residual current I0
device application Gateway,WAGES metering,Power monitoring,Multi-tariff
Type of measurement Current,Voltage,Frequency,Power factor,Energy,Active and reactive power
supply voltage 100...300 V DC,90...528 V AC 45...65 Hz
Network frequency 60 Hz,50 Hz
[In] rated current 1 A,5 A
type of network 3P + N,3P,1P + N
Maximum power consumption in VA 16 VA at 480 V
Ride-through time 35 ms 120 V AC typical,129 ms 230 V AC typical,50 ms 125 V DC typical
Display type Monochrome graphic LCD
Display resolution 128 x 128 pixels
Sampling rate 128 samples/cycle
Measurement current 50…10000 mA
Analogue input type Voltage (impedance 5 MOhm),Current (impedance <= 0.3 mOhm)
Measurement voltage 20…400 V AC 45...65 Hz between phase and neutral,20…828 V AC 45...65 Hz between phases
Frequency measurement range 45…65 Hz
Number of inputs 4 digital
Measurement accuracy Apparent power +/- 0.5 %,Frequency +/- 0.05 %,Active energy +/- 0.2 %,Reactive energy +/- 1 %,Active power +/- 0.2 %,Voltage +/- 0.1 %,Power factor +/- 0.005,Current +/- 0.15 %,Reactive power +/- 1 %
Accuracy class Class 0.2S active energy conforming to IEC 62053-22
Number of outputs 2 digital
Information displayed Tariff (8)
Communication port protocol Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V,JBUS,Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V,Ethernet Modbus TCP/IP daisy chain,BACnet IP,DNP3 over ethernet
Communication port support RS485,ETHERNET
Communication gateway Ethernet/serial
Data recording Event logs,Maintenance logs,Min/max of instantaneous values,Data logs,Alarm logs,Time stamping
Memory capacity 1.1 MB
Web services Alarm notification by e-mail,Web server,Diagnostic via predefined web pages,Real time viewing of data
Ethernet service SNTP client,SNMP-Traps
Connections - terminals Voltage circuit: screw terminal block4,Control circuit: screw terminal block2,Current transformer: screw terminal block6,RS485 link: screw terminal block4,Digital input: screw terminal block8,Digital output: screw terminal block4,Ethernet network: RJ45 connector2
mounting mode Flush-mounted
Mounting support Framework
Standards EN 50470-3,IEC 61557-12:2015,IEC 62053-22:2020,IEC 62053-24,IEC 60529,EN 50470-1,UL 61010-1,IEC 62053-23:2020,IEC 62052-11:2020,IEC 62052-31:2015
Product certifications CE conforming to IEC 61010-1,CULus conforming to UL 61010-1
Width 96 mm
Depth 72 mm
Height 96 mm
net weight 450 g

Environment

Electromagnetic compatibility Limits for harmonic current emissions class A conforming to IEC 61000-3-2,Conducted RF disturbances level 3 conforming to IEC 61000-4-6,Magnetic field at power frequency level 4 conforming to IEC 61000-4-8,Conducted and radiated emissions class B conforming to EN 55022,Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3,Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,Surge immunity test level 4 conforming to IEC 61000-4-5,Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protection IP54 display: conforming to IEC 60529,IP30 rear: conforming to IEC 60529
Relative humidity 5…95 % at 50 °C non-condensing
Pollution degree 2
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude <= 3000 m

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.0 cm
Package 1 Width 12.5 cm
Package 1 Length 12.5 cm
Package 1 Weight 647.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 12
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 8.152 kg
Unit Type of Package 3 P06
Number of Units in Package 3 96
Package 3 Height 75 cm
Package 3 Width 80 cm
Package 3 Length 60 cm
Package 3 Weight 73.216 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible