Description for RE8RA11FU Schneider Electric

RE8RA11FU Schneider Electric - Optimum industrial timing relay, Harmony Time, 0.1...10 s, type C, 110...240 V AC, 1 C/O

Free Delivery to UK Mainland on orders over £25

Main

range of product Zelio Time
product or component type Optimum industrial timing relay
Component name RE8
Time delay type C
Time delay range 0.1...10 s
Sale per indivisible quantity 1

Complementary

Discrete output type Relay
Contacts material Silver nickel contacts
Width pitch dimension 22.5 mm
[Us] rated supply voltage 110...240 V AC 50/60 Hz
Voltage range 0.9...1.1 Us
Connections - terminals Screw terminals, 2 x 1.5 mm² flexible with cable end,Screw terminals, 2 x 2.5 mm² flexible without cable end
Tightening torque 0.6…1.1 N.m
Setting accuracy of time delay +/- 20 % of full scale
Repeat accuracy < 1 %
Voltage drift < 2.5 %/V
Temperature drift < 0.2 %/°C
Minimum pulse duration 26 ms
Reset time 50 ms
Maximum switching voltage 250 V
Mechanical durability 20000000 cycles
[Ith] conventional free air thermal current 8 A
Maximum [Ie] rated operational current 2 A DC-13 24 V at 70 °C conforming to IEC 60947-5-1/1991,2 A DC-13 24 V at 70 °C conforming to VDE 0660,3 A AC-15 24 V at 70 °C conforming to IEC 60947-5-1/1991,3 A AC-15 24 V at 70 °C conforming to VDE 0660,0.1 A DC-13 250 V at 70 °C conforming to IEC 60947-5-1/1991,0.1 A DC-13 250 V at 70 °C conforming to VDE 0660,0.2 A DC-13 115 V at 70 °C conforming to IEC 60947-5-1/1991,0.2 A DC-13 115 V at 70 °C conforming to VDE 0660
Minimum switching capacity at 12 V 10 mA
Input voltage 110...240 V Y1 terminal(s)
Maximum switching current 10 mA (Y1)
Input compatibility 2-wire sensors DC with leakage current < 1 mA <50 m Y1 terminal(s)
marking CE
Overvoltage category III conforming to IEC 60664-1
[Ui] rated insulation voltage 250 V conforming to IEC,300 V conforming to CSA
Supply disconnection value > 0.1 Uc
Operating position Any position without derating
Surge withstand 2 kV conforming to IEC 61000-4-5 level 3
Power consumption in VA 1.8 VA at 110 V,8.5 VA at 240 V
Terminal description (Y1)UNUSED,(A1-A2)CO,(15-16-18)OC_ON
Height 78 mm
Width 22.5 mm
Depth 80 mm
net weight 0.11 kg

Environment

Immunity to microbreaks 3 ms
Standards EN/IEC 61812-1
Product certifications GL,CSA,UL
Ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -20…60 °C
Relative humidity 15…85 % 3K3 conforming to IEC 60721-3-3
Vibration resistance 0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6
IP degree of protection IP20 (terminals),IP50 (casing)
Pollution degree 3 conforming to IEC 60664-1
Dielectric test voltage 2.5 kV
Non-dissipating shock wave 4.8 kV
Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3
Resistance to fast transients 2 kV conforming to IEC 61000-4-4 level 3
Disturbance radiated/conducted CISPR 11 group 1 - class A,CISPR 22 - class A

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.7 cm
Package 1 Width 8.2 cm
Package 1 Length 8.5 cm
Package 1 Weight 100 g

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible