This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

REL50410

REL50410 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for REL50410 Schneider Electric

REL50410 Schneider Electric - PowerLogic⢠P5M30 48-250V 3CT 2Io 4VT 16DI-12DO

Extended Description for REL50410 Schneider Electric

REL50410 Schneider Electric - The PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications.,This motor relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time.,It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application.,The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats.,PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays.,The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC.,It works with conventional CTs/VTs. 3 phase current inputs, 1 standard neutral current input, 1 sensitive neutral current input and 4 voltage inputs.,It offers 16 digital inputs and 12 digital outputs and no communications. Communication modules can be added any time.,The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs).,PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification.,This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available.,Fixing and wiring accessories are included.,Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR/PRP FO (REL51033).,And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension/backup memory (REL51034).,IP54 flush mounting frame (REL51052), 8 temperature sensor module (59641), IRIG-B module (REL51045).,connection cords (59660, 59661, 59662).,eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance.,Included with functions as per the datasheet below.,For other configurations with additional functions and options, Please select via Product Selector.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£4,176.48 Exc. VAT
£5,011.78 Inc. VAT

Main

range of product PowerLogic P5
product or component type Protection and control relay
Relay application Motor
product reference P5M30-BACB-GAAAA-BAEA
Mounting case size 30TE
Device mounting Flush
mounting mode Withdrawable
power supply 48...250 V DC,100...230 V AC
measuring inputs : 1/5 A CT phase current 3, : 1/5 A CT residual current 1, : 1 A CT residual current 1, : VT voltage 4
Number of sensors 0 temperature sensor(s) ,0 arc sensor(s)
number of Digital Inputs (DI) 16
number of analogue inputs 0
number of Digital Outputs (DO) 11 DO,1 watchdog
number of analogue outputs 0
communication ports USB port 2 front
communication protocols -
Cybersecurity Port hardening,Firmware signature,Client IP address filter,Secured communication with assciated tools,Security policy management,Role-based access control,Security log,LDAP,RADIUS based user authentication,IEC 62443-4-2 SL1
protection functions Phase overcurrent 50/51,Directional phase overcurrent 67,Earth fault overcurrent 50N/51N,Restricted earth fault 64REF,Directional earth fault 67N,Transient earth fault 67NI,Neutral admittance 21YN,Earth fault wattmetric 32N,Broken conductor 46 I2/I1,Current unbalance 46 I2/I1,Cold load pick-up,Switch ON to fault (SOTF),H2 detection,H5 detection,Breaker failure 50BF,Directional active underpower 37P,Phase undercurrent 37,Excessive starting time, locked rotor 48/51LR,Motor restart inhibition 66,Negative sequence overcurrent 46,Overvoltage 59,Undervoltage 27,Positive sequence undervoltage 27P,Earth fault overvoltage 59N,Underfrequency 81/81N,Lockout relay 86,CT supervision 60,VT supervision 60,Programmable stages 99,Programmable logic,Programmable curve
measurement functions Current 3-phase,Current zero sequence,Current positive sequence,Current negative sequence,Current ratio of negative and positive,Phasor diagram of currents or voltages,Current 2nd, 15th harmonics with THD,Voltage 3-phase,Voltage residual,Voltage zero sequence,Voltage positive sequence,Voltage negative sequence,Frequency
control functions Switchgear control and monitoring,Programmable switchgear interlocking,Local/remote control
controllable switchgear devices 6 controlled + 2 monitored objects
number of setting groups 4
monitoring functions Trip circuit supervision 74,Circuit breaker monitoring,Relay self-monitoring
logs and records Event recording,Disturbance recording,Tripping context,Relay maintenance
Switchgear diagnosis type CT/VT supervision ANSI code: 60,Trip circuit supervision ANSI code: 74
Connections - terminals Screw (digital input/output),Ring lugs (analog inputs and outputs)

Complementary

Software name ESetup Easergy Pro: virtual simulation test
Display type Colour LCD 480 x 272 pixels
Number of key 7 customizable
Local signalling 4 x LED,10 x LED tri-colour programmable
Height 176 mm
Width 152 mm
Depth 219 mm
Net weight 3.5 kg

Environment

climatic withstand Exposure to cold conforming to IEC 60068-2-1,Exposure to dry heat conforming to IEC 60068-2-2,Exposure to damp heat in service conforming to IEC 60068-2-78,Exposure to damp heat in service conforming to IEC 60068-2-30,Temperature variation conforming to IEC 60068-2-14,Salt mist conforming to IEC 60068-2-52,Influence of corrosion/gas test 2 conforming to IEC 60068-2-60,Influence of corrosion/gas test 4 conforming to IEC 60068-2-60,Influence of corrosion/gas test 2 conforming to IEC 60721-3-3,Influence of corrosion/gas test 4 conforming to IEC 60721-3-3
Mechanical robustness Vibrations (level: class 2) conforming to IEC 60255-21-1,Vibrations conforming to GOST 17516.1,Vibrations conforming to IACS E10,Shocks (level: class 2) conforming to IEC 60255-21-2,Earthquakes (level: class 2) conforming to IEC 60255-21-3
Electromagnetic compatibility Emission tests class A conforming to CISPR 11,Emission tests class A conforming to CISPR 32,Emission tests conforming to IACS E10,EMC immunity class 4 conforming to IEC 61000-4-2,EMC immunity class 4 conforming to ANSI C37.90.3,EMC immunity level 3 conforming to IEC 61000-4-3,EMC immunity conforming to ANSI C37.90.2,EMC immunity conforming to GOST 32137,EMC immunity conforming to GOST 30804.4.3,EMC immunity conforming to IACS E10,EMC immunity level 5 conforming to IEC 61000-4-8,EMC immunity level 5 conforming to IEC 61000-4-9,EMC immunity level 5 conforming to IEC 61000-4-10,EMC immunity level 3 conforming to IEC 61000-4-6,EMC immunity level 3 conforming to IEC 61000-4-18,EMC immunity conforming to ANSI C37.90.1,EMC immunity conforming to IEC 61000-4-12,EMC immunity conforming to GOST 30804.4.12,EMC immunity level 4 conforming to IEC 61000-4-16,EMC immunity level 4 conforming to IEC 61000-4-4,EMC immunity level 4 conforming to IEC 61000-4-5
Ambient air temperature for operation -40…85 °C ( 16 h ) ,-40…70 °C ( 96 h )
IP degree of protection IP54 conforming to IEC 60529
maximum operating altitude 2000 m
Protective treatment Conformal coating conforming to IEC 60068-2-52:Kb/1,Conformal coating conforming to IEC 60068-2-60:Ke,Conformal coating conforming to IEC 60721-3-3:3C2
Relative humidity 0…93 % at 40 °C, without condensation, 56 days,93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.0 cm
Package 1 Width 30.0 cm
Package 1 Length 35.0 cm
Package 1 Weight 4.5 kg

Contractual warranty

Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible