REL52040 Schneider Electric - PowerLogic P3U20, 4L ringlug, 1U, 10DI/5DO, Uaux: 48-230V, DI: 110-230V, 2 x LC

Extended Description for REL52040 Schneider Electric

REL52040 Schneider Electric - Perfectly suited for buildings and industry, utilities, and large industrial processes.,The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI.,It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others.,Simple, reliable, safe and easy-to-use, thanks to the User Interface display.,The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network.,It include 10 digital inputs, 2 LC communication ports and 1 USB on front of the device.,Mechanical dimensions are 169.5 mm in height, 170 mm in width and 205 mm in depth.,The relays are certified with EN 60255-26 for electromagnetic compatiblity.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£2,001.97 Exc. VAT
£2,402.36 Inc. VAT

Main

range of product PowerLogic P3
product or component type Protection relay
Relay application Universal
product reference P3U20-6AAA2ADAA
Mounting case size 20TE
power supply 48...230 V AC/DC
measuring inputs : 1/5 A CT phase current 3, : 1/5 A CT residual current 1, : 100 V/110 V VT voltage 1
number of Digital Inputs (DI) 10
number of analogue inputs 0
number of Digital Outputs (DO) 1 watchdog,5
number of analogue outputs 0
communication ports USB port 1 front,LC 2 rear
communication protocols IEC 61850 ed. 1,IEC 61850 ed. 2,IEC 60870-5-101,DNP3 TCP,Modbus TCP,EtherNet/IP
Redundancy communication port protocol RSTP,PRP
Cybersecurity Password protection,Port hardening
protection functions Phase undercurrent 37,Negative sequence overcurrent 46,Broken conductor 46 I2/I1,Excessive starting time, locked rotor 48/51LR,Thermal overload protection 49,Phase overcurrent 50/51,Earth fault overcurrent 50N/51N,Breaker failure 50BF,Switch ON to fault (SOTF),Capacitor bank unbalance 51C,Capacitor overvoltage 59C,Neutral voltage displacement 59N,Motor restart inhibition 66,Directional earth fault 67N,Transient earth fault 67NI,CT supervision 60,VT supervision 60,H2 detection 68H2,H5 detection 68H5,Recloser 79,Lockout relay 86,Cold load pick-up,Programmable stages 99,Programmable curve
Arc flash protection No
measurement functions Current 3-phase,Current zero sequence,Current positive sequence,Current negative sequence,Current ratio of negative and positive,Voltage phase to earth,Voltage phase to phase,Voltage zero sequence,Voltage positive sequence,Voltage negative sequence,Voltage ratio of negative and positive,Short circuit fault reactance,Fault location current,Earth fault reactance,Frequency,Active power,RMS active power,Reactive power,RMS reactive power,Apparent power,RMS apparent power,Active energy,Reactive energy,Cos φ,Tan φ,Power angle,Power factor,Voltage phasor diagram view,Current phasor diagram view,Current 2nd, 15th harmonics with THD,Voltage 2nd, 15th harmonics with THD,Voltage interruption,Condition monitoring CB wear
control functions Switchgear control and monitoring,Programmable switchgear interlocking,Local control on single-line diagram,Local control with I/O keys,Local/remote control,2 function keys,Mobile application with Easergy SmartApp,Web-server,Programmable logic
controllable switchgear devices 2 controlled + 4 displayed
number of setting groups 4
monitoring functions Trip circuit supervision 74,Circuit breaker monitoring,Relay self-monitoring
logs and records Event recording,Disturbance recording,Tripping context
Switchgear diagnosis type CT supervision,Trip circuit supervision ANSI code: TCS
Connections - terminals Screw removable (digital input/output),Ring lugs removable (current transformer),Pin removable (voltage transformer)

Complementary

Operating threshold 110...230 V AC/DC
Software name EcoStruxure Power Device,ESetup Easergy Pro
Web server Embedded HTTP server
Display type LCD 128 x 64 pixels with single line diagram
Number of key 2 customizable
Local signalling 4 LEDs,8 LEDs programmable
Standards IEC
Height 169.5 mm
Width 170 mm
Depth 205 mm
Net weight 2.5 kg maximum

Environment

climatic withstand Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2,Exposure to cold Ad tests conforming to EN/IEC 60068-2-1,Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30,Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78
Mechanical robustness Vibrations (level: class II) conforming to IEC 60255-21-1,Vibrations: Fc conforming to IEC 60068-2-6,Shocks (level: class II) conforming to IEC 60255-21-2,Shocks: Ea conforming to IEC 60068-2-27,Seismic tests method A (level: class II) conforming to IEC 60255-21-3,Bumps (level: class II) conforming to IEC 60255-21-2,Bumps: Ea conforming to IEC 60068-2-27
Electromagnetic compatibility Emission tests conforming to IEC/EN 60255-26 ed. 3,Emission tests class A conforming to CISPR 11,Emission tests class A conforming to CISPR 22,EMC immunity conforming to IEC/EN 60255-26 ed. 3,EMC immunity conforming to EN/IEC 61000-4-18,EMC immunity level 4 conforming to EN/IEC 61000-4-2,EMC immunity level 3 conforming to EN/IEC 61000-4-3,EMC immunity level 4 conforming to EN/IEC 61000-4-4,EMC immunity level 3 conforming to EN/IEC 61000-4-5,EMC immunity level 3 conforming to EN/IEC 61000-4-6,EMC immunity conforming to EN/IEC 61000-4-8,EMC immunity level 5 conforming to EN/IEC 61000-4-9,EMC immunity conforming to EN/IEC 61000-4-29,EMC immunity conforming to EN/IEC 61000-4-11,EMC immunity conforming to EN/IEC 61000-4-17
Ambient air temperature for operation -40…65 °C
IP degree of protection IP54 conforming to IEC 60529
maximum operating altitude 2000 m
Protective treatment Conformal coating
Relative humidity 0…95 %, without condensation

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 16 cm
Package 1 Width 21.5 cm
Package 1 Length 27.5 cm
Package 1 Weight 3.5 kg

Contractual warranty

Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)

Documentation

Product Datasheet

User guide

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible