Schneider Electric

REL52119

REL52119 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for REL52119 Schneider Electric

REL52119 Schneider Electric - PowerLogic P3F30 24-48V 16DI 9DO 3CT 4VT 2Io 2RJ45 DI24V

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£3,435.66 Exc. VAT
£4,122.79 Inc. VAT

Main

range of product PowerLogic P3
product or component type Protection relay
Relay application Feeder
product reference P3F30-DGIAA-DAENA-BAAAA
Mounting case size 30TE
power supply 24...48 V DC
measuring inputs : 1/5 A CT phase current 3, : 5/1 A CT residual current 1, : 1/0.2 A CT residual current 1, : 100 V/110 V VT voltage 4
Number of sensors 0 temperature sensor(s) ,0 arc sensor(s)
number of Digital Inputs (DI) 16
number of analogue inputs 0
number of Digital Outputs (DO) 1 watchdog,9
number of analogue outputs 0
communication ports USB port 1 front,RJ45 2 rear
communication protocols IEC 61850 ed. 1,IEC 61850 ed. 2,IEC 60870-5-101,DNP3 TCP,Modbus TCP,EtherNet/IP
Redundancy communication port protocol RSTP,PRP
Cybersecurity Password protection,Port hardening
protection functions Phase overcurrent 50/51,Directional phase overcurrent 67,Earth fault overcurrent 50N/51N,Directional earth fault 67N,Transient earth fault 67NI,Capacitor bank unbalance 51C,Broken conductor 46 I2/I1,Cold load pick-up,Switch ON to fault (SOTF),Breaker failure 50BF,Directional active underpower 37P,Fault locator 21FL,Recloser 79,Phase undercurrent 37,Excessive starting time, locked rotor 48/51LR,Motor restart inhibition 66,Capacitor overvoltage 59C,Negative sequence overcurrent 46,Overvoltage 59,Undervoltage 27,Positive sequence undervoltage 27P,Earth fault overvoltage 59N,Underfrequency 81/81N,Rate of change of frequency 81R,Synchro-check 25,Lockout relay 86,CT supervision 60,VT supervision 60,H2 detection 68H2,H2 detection,H5 detection 68H5,H5 detection,Programmable stages 99,Programmable curve
Arc flash protection Yes (8 stages)
measurement functions Current 3-phase,Current zero sequence,Current positive sequence,Current negative sequence,Current ratio of negative and positive,Voltage phase to earth,Voltage phase to phase,Voltage zero sequence,Voltage positive sequence,Voltage negative sequence,Voltage ratio of negative and positive,Short circuit fault reactance,Fault location current,Earth fault reactance,Frequency,Active power,RMS active power,Reactive power,RMS reactive power,Apparent power,RMS apparent power,Active energy,Reactive energy,Cos φ,Tan φ,Power angle,Power factor,Voltage phasor diagram view,Current phasor diagram view,Current 2nd, 15th harmonics with THD,Voltage 2nd, 15th harmonics with THD,Voltage interruption,Condition monitoring CB wear
control functions Switchgear control and monitoring,Programmable switchgear interlocking,Local control on single-line diagram,Local control with I/O keys,Local/remote control,2 function keys,Mobile application with Easergy SmartApp,Web-server,Programmable logic
controllable switchgear devices 6 controlled + 8 displayed
number of setting groups 4
monitoring functions Trip circuit supervision 74,Circuit breaker monitoring,Relay self-monitoring
logs and records Event recording,Disturbance recording,Tripping context
Switchgear diagnosis type CT/VT supervision ANSI code: 60,CT supervision,Trip circuit supervision ANSI code: TCS
Connections - terminals Screw removable (digital input/output),Pin fixed (current transformer),Pin removable (voltage transformer)

Complementary

Operating threshold 24...230 V AC/DC
Time synchronisation protocol SNTP
Software name EcoStruxure Power Device,ESetup Easergy Pro
Web server Embedded HTTP server
Display type LCD 128 x 128 pixels with single line diagram
Number of key 2 customizable
Local signalling 2 LEDs,16 LEDs programmable
Standards IEC
Height 176 mm
Width 270 mm
Depth 230 mm
Net weight 4.2 kg maximum

Environment

climatic withstand Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2,Exposure to cold Ad tests conforming to EN/IEC 60068-2-1,Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30,Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78
Mechanical robustness Vibrations (level: class II) conforming to IEC 60255-21-1,Vibrations: Fc conforming to IEC 60068-2-6,Shocks (level: class II) conforming to IEC 60255-21-2,Shocks: Ea conforming to IEC 60068-2-27,Seismic tests method A (level: class II) conforming to IEC 60255-21-3,Bumps (level: class II) conforming to IEC 60255-21-2,Bumps: Ea conforming to IEC 60068-2-27
Electromagnetic compatibility Emission tests conforming to IEC/EN 60255-26 ed. 3,Emission tests conforming to CISPR 11,Emission tests conforming to CISPR 22,EMC immunity conforming to IEC/EN 60255-26 ed. 3,EMC immunity conforming to EN/IEC 61000-4-18,EMC immunity level 4 conforming to EN/IEC 61000-4-2,EMC immunity level 3 conforming to EN/IEC 61000-4-3,EMC immunity level 4 conforming to EN/IEC 61000-4-4,EMC immunity level 3 conforming to EN/IEC 61000-4-5,EMC immunity level 3 conforming to EN/IEC 61000-4-6,EMC immunity conforming to EN/IEC 61000-4-8,EMC immunity level 5 conforming to EN/IEC 61000-4-9,EMC immunity conforming to EN/IEC 61000-4-29,EMC immunity conforming to EN/IEC 61000-4-11,EMC immunity conforming to EN/IEC 61000-4-17
Ambient air temperature for operation -40…65 °C
IP degree of protection IP54 conforming to IEC 60529
maximum operating altitude 2000 m
Protective treatment Conformal coating
Relative humidity 0…95 %, without condensation

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21 cm
Package 1 Width 26 cm
Package 1 Length 31.5 cm
Package 1 Weight 5.2 kg

Contractual warranty

Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible