This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

RM22UA21MR

RM22UA21MR Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for RM22UA21MR Schneider Electric

RM22UA21MR Schneider Electric - Overvoltage control relay 50mVâ¦5Vac/dc, 2 C/O

Extended Description for RM22UA21MR Schneider Electric

RM22UA21MR Schneider Electric - This Harmony RM17-U control relay allows monitoring of overvoltage control.,This modular control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels.,It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water.,It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device.,It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers.,It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting.,Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£62.23 Exc. VAT
£74.67 Inc. VAT

Main

range of product Harmony Control Relays
Relay type Voltage control relay
product or component type Voltage control relay
Network number of phases 1 phase
Supply circuit type DC
Relay name RM22UA
Relay monitored parameters Overvoltage detection
time delay Without
Switching capacity in VA 2000 VA
Measurement range 0.05...5 V AC/DC
Contacts type and composition 2 C/O

Complementary

Reset time 1500 ms at maximum voltage
Maximum switching voltage 250 V AC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC
Supply voltage limits 20.4…264 V AC/DC
Power consumption in VA 3.5 VA AC
Maximum power consumption in W 1.5 W DC
Immunity to microbreaks 10 ms
Resistance across terminals 30 kOhm at E2-M terminals,5 kOhm at E1-M terminals,50 kOhm at E3-M terminals
Output contacts 2 C/O
Hysteresis 5…50 % adjustable of threshold setting
delay at power up 600 ms
Maximum measuring cycle 100 ms measurement cycle as true rms value
Repeat accuracy +/- 0.5 % for input and measurement circuit
Measurement error < 1 % over the whole range with voltage variation,0.05 %/°C with temperature variation
Response time <= 500 ms
Insulation resistance > 100 MOhm at 500 V DC
Overvoltage category III conforming to IEC 60664-1
Insulation Between supply and measurement
Connections - terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end,Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end,Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end,Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Mounting support 35 mm DIN rail conforming to IEC 60715
Electrical durability 100000 cycles
Mechanical durability 10000000 cycles
Utilisation category AC-15 conforming to IEC 60947-5-1,DC-13 conforming to IEC 60947-5-1,AC-1 conforming to IEC 60947-4-1,DC-1 conforming to IEC 60947-4-1
[Un] rated nominal voltage 24...240 V AC/DC 50/60 Hz, non self-powered
Safety reliability data B10d = 290000,MTTFd = 308.2 years
Contacts material Cadmium free
Control type With test button
Width 22.5 mm
net weight 0.11 kg

Environment

Electromagnetic compatibility Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1,Immunity for industrial environments conforming to IEC 61000-6-2,Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3,Emission standard for industrial environments conforming to IEC 61000-6-4,Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2,Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4,Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4,Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5,Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5,Conducted and radiated emissions class B group 1 conforming to CISPR 11,Conducted and radiated emissions class B conforming to CISPR 22
Ambient air temperature for operation -20…50 °C at 60 Hz,-20…60 °C at 50 Hz
Standards IEC 60255-1
Product certifications UL,EAC,CSA,GL,CCC,RCM,CE
Ambient air temperature for storage -40…70 °C
Relative humidity 93…97 % at 25…55 °C conforming to IEC 60068-2-30
Vibration resistance 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6,1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6,0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6,0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
Shock resistance 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27,5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protection IP20 (terminals) conforming to IEC 60529,IP40 (housing) conforming to IEC 60529,IP50 (front panel) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Dielectric test voltage 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.6 cm
Package 1 Width 8.2 cm
Package 1 Length 9.5 cm
Package 1 Weight 120.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 40
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 5.189 kg
Unit Type of Package 3 P06
Number of Units in Package 3 640
Package 3 Height 50.0 cm
Package 3 Width 80.0 cm
Package 3 Length 60.0 cm
Package 3 Weight 92.58 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible