This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

VLS3P040D1

VLS3P040D1 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for VLS3P040D1 Schneider Electric

VLS3P040D1 Schneider Electric - Disconnect switch, TeSys VLS, body switch, 40A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, door mount

Extended Description for VLS3P040D1 Schneider Electric

VLS3P040D1 Schneider Electric - These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more.,This family of disconnect switches has switches ranging from 16A to 125A.,The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated.,The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated.,This 40A disconnect switch has 3 normally open poles and mounts directly in the enclosure door.,Per UL and CSA this this disconnect switch has a 2 HP rating at 120 VAC and a 5 HP at 240 VAC single phase.,Per UL and CSA this disconnect switch has a 10 HP rating at 200 to 208 VAC, a 15 HP rating at 240 VAC, a 20 HP rating at 480 VAC and a 25 HP rating at 600 VAC three phase.,Per UL508A this this disconnect switch has up to a 5 kA at 600 V short circuit current rating (SCCR) with a 30A Type RK5 fuse maximum.,Per IEC requirements, this disconnect switch has a 18.5 kW rating at 400 V, a 18.5 kW rating at 500 V and a 22 kW rating at 690V three phase.,The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 18 AWG to 6 AWG.,This disconnect switch is 3.07 inches tall, 1.77 inches wide and 2.87 inches deep. The switch weighs 0.30 lbs.,There are many handles and accessories available this TeSys VLS disconnect switch.,This TeSys VLS disconnect switch is UL Listed per UL60947-4-1, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£53.97 Exc. VAT
£64.76 Inc. VAT

Main

Range TeSys
Product Name TeSys VARIO LS
Device Short Name VLS3P
Product Type Switch body

Complementary

Mounting Support Door
Performance Level High performance
Number of Poles 3P
Contact Type and Composition 3 NO
Color Grey
[Ue] UL Rated Operational Voltage 600 V AC 50/60 Hz conforming to UL 508
Network type AC
Network frequency 50/60 Hz
UL Maxium Horsepower Ratings 10 hp at 200/208 V AC,15 hp at 240 V AC,20 hp at 480 V AC,25 hp at 600 V AC,2 hp at 120 V AC,5 hp at 240 V AC
[Ue] IEC Rated Operational Voltage 690 V AC 50/60 Hz
IEC Rated Operational Power in W 18.5 kW at 400 V (AC-23A),18.5 kW at 500 V (AC-23A),22 kW at 690 V (AC-23A)
[Ie] Rated Operational Current 40 A Ue: 600 V conforming to UL 508,40 A AC-21A Ue: 400 V,40 A AC-21A Ue: 500 V,40 A AC-21A Ue: 690 V,40 A AC-22A Ue: 400 V,40 A AC-22A Ue: 500 V,40 A AC-22A Ue: 690 V,40 A AC-23A Ue: 400 V,25 A AC-23A Ue: 500 V,25 A AC-23A Ue: 690 V
[Ith] Conventional Free Air Thermal Current 40 A (at 55 °C)
[Ithe] Conventional Enclosed Thermal Current 40 A
Making capacity ( I Rms) 120 A at 690 V AC-22A,400 A at 690 V AC-23A,60 A at 690 V AC-21A
Breaking Capacity 60 A at 690 V (AC-21A),120 A at 690 V (AC-22A),320 A at 690 V (AC-23A)
SCCR Fuse RK5 45 A maximum: 5 kA at 600 V AC
Rated Conditional Short Circuit Current 50 kA at 400 V - associated fuse 40 A gG
[Icm] Rated Short Circuit Making Capacity 1128 A at 690 V
Intermittent duty class Class 120 - 60 %
[Uimp] rated impulse withstand voltage 8 kV
[Icw] rated short-time withstand Rms current 800 A at 690 V duration: 1 s
Mechanical Durability 100000 cycles
Electrical Durability 100000 cycles AC-21A
UL Wire Size AWG 18...AWG 6 copper
IEC Terminal Connection Power circuit: screw clamp terminals10 mm² - solid,Power circuit: screw clamp terminals16 mm² - flexible - without cable end
Tightening Torque Power circuit: 1.8…2 N.m - on screw clamp terminals
Height 73 mm
Width 45 mm
Depth 78 mm
Product Weight 0.135 kg

Environment

Standards UL 508,CSA C22.2 No 14,IEC 60947-3
Product Certifications cULus,GL
Degree of Protection IP20 conforming to IEC 60529
Mechanical Robustness Vibrations 2...100 Hz Fc (0.7 g) conforming to IEC 60068-2-6,Shocks 11 ms Ea (15 gn) conforming to IEC 60068-2-27
Ambient Air Temperature for Operation -25…55 °C
Fire Resistance 960 °C conforming to IEC 60695-2-11

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.0 cm
Package 1 Width 8.5 cm
Package 1 Length 12.0 cm
Package 1 Weight 194.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 27
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 5.951 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Looking for a specific part?