This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

XPSBAC14AP

XPSBAC14AP Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for XPSBAC14AP Schneider Electric

XPSBAC14AP Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 24 V AC/DC , no inputs, screw

Extended Description for XPSBAC14AP Schneider Electric

XPSBAC14AP Schneider Electric - This safety relay is designed for monitoring Emergency stop and Guard switch.,The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block.,This basic safety modules embeds pre-defined safety functions.,This safety relay embeds 1 control output, 4 NO safety outputs, and 2 NC diagnostic outputs.,The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO13849-1, SILCL 3 conforming to IEC62061, SIL 3 conforming to IEC61508.,This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height).,This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging.,This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÃV.,Harmony safety relays are compatible with Modicon logic controllers.,This relay is mounted on a 35mm symmetrical DIN rail.,Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity.,Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.

Free Delivery to UK Mainland on orders over £25

Manufacturer New

5 available
1 - 2 w.days
£224.21 Exc. VAT (Price type)
£269.05 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£88.71 Exc. VAT
£106.45 Inc. VAT

Main

range of product Harmony Safety Automation
product or component type Safety module
Safety module name XPSBAC
Safety module application For emergency stop and protective guard applications
Function of module Emergency stop button with 2 NC contacts,Guard monitoring with 1 or 2 limit switches
Safety level Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1,Can reach SILCL 3 for normally open relay contact conforming to IEC 62061,Can reach SIL 3 for normally open relay contact conforming to IEC 61508,Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1,Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061,Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Safety reliability data MTTFd > 30 years conforming to ISO 13849-1 for normally open relay contact,Dcavg >= 99 % conforming to ISO 13849-1 for normally open relay contact,PFHd = 0.95E-09 conforming to ISO 13849-1 for normally open relay contact,HFT = 1 conforming to IEC 62061 for normally open relay contact,PFHd = 0.95E-09 conforming to IEC 62061 for normally open relay contact,SFF > 99% conforming to IEC 62061 for normally open relay contact,HFT = 1 conforming to IEC 61508-1 for normally open relay contact,PFHd = 0.95E-09 conforming to IEC 61508-1 for normally open relay contact,SFF > 99% conforming to IEC 61508-1 for normally open relay contact,Type = B conforming to IEC 61508-1 for normally open relay contact,MTTFd > 30 years conforming to ISO 13849-1 for normally closed relay contact,DC > 60 % conforming to ISO 13849-1 for normally closed relay contact,PFHd = 0.95E-09 conforming to ISO 13849-1 for normally closed relay contact,HFT=0 conforming to IEC 62061 for normally closed relay contact,PFHd = 0.95E-09 conforming to IEC 62061 for normally closed relay contact,SFF > 60% conforming to IEC 62061 for normally closed relay contact,HFT=0 conforming to IEC 61508-1 for normally closed relay contact,PFHd = 0.95E-09 conforming to IEC 61508-1 for normally closed relay contact,SFF > 60% conforming to IEC 61508-1 for normally closed relay contact,Type = B conforming to IEC 61508-1 for normally closed relay contact
electrical circuit type NC pair
Connections - terminals Removable screw terminal block, 0.2...2.5 mm² solid or flexible,Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor,Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor,Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel,Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage 24 V AC - 15...10 %,24 V DC - 20...20 %

Complementary

Synchronisation time between inputs Unlimited
Type of start Automatic/manual/monitored
Power consumption in W 1.5 W 24 V DC
Power consumption in VA 3.5 VA 24 V AC 50/60 Hz
Input protection type Internal, electronic
safety outputs 4 NO + 1 NC
safety inputs 0
Input compatibility Normally closed circuit conforming to ISO 14119,XC limit switch conforming to ISO 14119,Mechanical contact conforming to ISO 14119,Normally closed circuit conforming to ISO 13850
input terminal Power supply
[Ie] rated operational current 5 A AC-1 for normally open relay contact,3 A AC-15 for normally open relay contact,5 A DC-1 for normally open relay contact,3 A DC-13 for normally open relay contact,3 A AC-1 for normally closed relay contact,1 A AC-15 for normally closed relay contact,3 A DC-1 for normally closed relay contact,1 A DC-13 for normally closed relay contact
control outputs 0
[Ith] conventional free air thermal current 6 A
Associated fuse rating 10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum output current 10 mA for relay output
Minimum output voltage 5 V for relay output
Response time 150 ms at 24 V AC,80 ms at 24 V DC
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category II conforming to IEC 60947-1
Local signalling LED green with power marking for power ON,LED red with error marking for error,LED yellow with state marking for status,LED yellow with start1 marking for start input,LED yellow with start2 marking for start input
mounting support 35 mm symmetrical DIN rail
Depth 120 mm
Height 100 mm
Width 22.5 mm
net weight 0.200 kg

Environment

Ambient air temperature for operation -25…55 °C
Standards IEC 60947-5-1,IEC 61508-1 functional safety standard,IEC 61508-2 functional safety standard,IEC 61508-3 functional safety standard,IEC 61508-4 functional safety standard,IEC 61508-5 functional safety standard,IEC 61508-6 functional safety standard,IEC 61508-7 functional safety standard,ISO 13849-1 functional safety standard,IEC 62061 functional safety standard
Product certifications TÜV,cULus
IP degree of protection IP20 (terminals) conforming to IEC 60529,IP40 (housing) conforming to IEC 60529,IP54 (mounting area) conforming to IEC 60529
Relative humidity 5…95 % non-condensing

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.500 cm
Package 1 Width 13.500 cm
Package 1 Length 15.500 cm
Package 1 Weight 301.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 16
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.556 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 52.000 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible