This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

XPSMF3542

XPSMF3542 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for XPSMF3542 Schneider Electric

XPSMF3542 Schneider Electric - Preventa safety PLC compact - Profibus DP protocol

Free Delivery to UK Mainland on orders over £25

Main

range of product Preventa Safety automation
product or component type Preventa safety PLC compact
Safety module name XPSMF35
Safety module application For numerous machine safety functions and for the protection of personnel
Safety use category Category 4 conforming to EN 954-1/ISO 13849-1,SIL 3 conforming to IEC 61508
Structure type 10BASE-T/100BASE-TX, Modbus TCP/IP,10BASE-T/100BASE-TX, safe Ethernet

Complementary

Function of module Closed circuit scanning of input channels for analogue input circuit,Measuring 0 to 20 mA currents using shunt for analogue input circuit,Monitoring safety actuators for discrete output,Monitoring safety detection for discrete input,Monitoring safety dialogue for discrete input,Monitoring safety dialogue for discrete output,Single-pole measuring of 0 to 10 V voltages for analogue input circuit
[Us] rated supply voltage 24 V DC - 15...20 %
no load current 0.75 A
Protection type Internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response time Depending on size of application
Memory description User logic 250 kB application,User logic 250 kB data
Discrete input number 24 not isolated discrete input(s)
Voltage state 0 guaranteed <= 5 V for discrete input
Voltage state 1 guaranteed 24...30 V for discrete input
Current state 0 guaranteed 1...1.5 mA (discrete input)
Current state 1 guaranteed 3.5...4.5 mA (discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Input protection type Protected against short-circuit to earth,Protected against short-circuit
Input overvoltage protection 500 V for discrete input conforming to IEC 61000-4-5,-4…15 V for analogue input circuit
Discrete output number 8
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2 %
Discrete output current 1 A at 60 °C (channels 4 and 8),2 A at 50 °C (channels 4 and 8),0.5 A at 60 °C (channels 1 to 3 and 5 to 7),<= 7 mA (all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA, at 2 V at state 0 for discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Analogue input number 8
Analogue output type Not isolated
External resistance 250 Ohm for analogue input circuit,500 Ohm for analogue input circuit
Analogue input range 0...20 mA with 500 Ohm shunt,0...10 V
Input voltage limits 0.1...11.5 V analogue input circuit
Input current limits 0.4…23 mA 500 Ohm analogue input circuit
Analogue input resolution 12 bits
Safety accuracy +/- 2 % for analogue input circuit
Maximum internal input resistance 500 MOhm for signal source for analogue input circuit,1 kOhm for analogue input circuit,3.7 Ohm for counting inputs
Counting input number 2
Counting input type Non isolated
Counting frequency 100 kHz
Operating threshold 0...0.05 V, 5 V low for counting inputs,13...33 V, 24 V high for counting inputs,-3...5 V, 24 V low for counting inputs,4...6 V, 5 V high for counting inputs
Counter inputs resolution 24 bits
DV/dt 1 V/µs counting inputs
Communication port protocol Modbus TCP/IP with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better,Safe Ethernet with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better,Modbus RTU with 1 SUB-D 9-pin female port(s), RS485, medium: shielded dual twisted pair cable,Profibus with 1 SUB-D 9-pin female port(s), RS485, medium: shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation Modbus TCP/IP,Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave Modbus,Slave Modbus TCP/IP,Slave Profibus
Number of addresses 122 for Modbus
Concept Transparent Ready, Modbus TCP/IP
Web server Class A10, Modbus TCP/IP
Web services Modbus identification request, Modbus TCP/IP,Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP,Modbus TCP/IP server, Modbus TCP/IP,Standard 502, Modbus TCP/IP
Operating distance <= 500 m (between station) shielded dual twisted pair cable counting inputs,<= 100 m (between station) discrete input,<= 100 m (between station) discrete output,<= 300 m (between station) analogue input circuit
Number of terminal blocks 1 for counting inputs,1 for power supply,2 for discrete output,4 for analogue input circuit,5 for discrete input
Connections - terminals Analogue input circuit: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end,Counting inputs: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end,Discrete input/output circuit: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end,Discrete input/output circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end,Discrete input/output circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end,Power supply: captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible without cable end,Power supply: captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) solid without cable end,Discrete input/output circuit: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end,Discrete input/output circuit: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end,Power supply: captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² (AWG 22...AWG 16) flexible with cable end,Power supply: captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² (AWG 22...AWG 16) flexible without cable end,Discrete input/output circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end,Discrete input/output circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end,Power supply: captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 12) flexible without cable end,Power supply: captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 12) solid without cable end,Discrete input/output circuit: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end,Power supply: captive screw clamp terminals, 2 x 0.25...2 x 1 mm² (AWG 22...AWG 18) flexible without cable end,Power supply: captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² (AWG 22...AWG 16) flexible with cable end,Analogue input circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end,Counting inputs: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end,Analogue input circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end,Counting inputs: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end,Analogue input circuit: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end,Counting inputs: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end,Analogue input circuit: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end,Counting inputs: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end,Analogue input circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end,Counting inputs: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end,Analogue input circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end,Counting inputs: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end,Analogue input circuit: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end,Counting inputs: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end
Tightening torque 0.22…0.25 N.m
Wire stripping length 9 mm
Current consumption 9 A at 24 V DC on power supply
mounting support 35 mm symmetrical DIN rail
Depth 66.5 mm
Height 113 mm
Width 253 mm
net weight 1.2 kg

Environment

Standards IEC 61131,DIN V 19250,DIN V 0801,EN 50156 pending
Immunity to microbreaks 10 ms
IP degree of protection IP20 (enclosure)
Ambient air temperature for operation 0…60 °C conforming to EN 61131-2
Ambient air temperature for storage -40…85 °C conforming to EN 61131-2
Relative humidity 95 % supply not connected
Operating altitude < 2000 m
Pollution degree 2
Electrical shock protection class Class II conforming to EN/IEC 61131-2
Electromagnetic compatibility EN/IEC 61131-2
Vibration resistance 1 gn conforming to EN 61131-2 (f = 10…150 Hz)
Shock resistance 15 gn for 11 ms conforming to EN 61131-2
Resistance to electrostatic discharge 4 kV contact conforming to EN/IEC 61000-4-2,8 kV on air conforming to EN/IEC 61000-4-2
Resistance to electromagnetic fields 10 V/m 26…1000 MHz conforming to EN/IEC 61000-4-3

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.5 cm
Package 1 Width 19.0 cm
Package 1 Length 29.5 cm
Package 1 Weight 1.915 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Catalogue

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image