This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3LD2264-1GP53

3LD2264-1GP53 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3LD2264-1GP53 Siemens

3LD2264-1GP53 Siemens - Siemens 3P Pole Isolator Switch - 32A Maximum Current, 11.5kW Power Rating, IP65

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£54.82 Exc. VAT
£65.78 Inc. VAT

Product

Article Number (Market Facing Number) 3LD2264-1GP53
Product Description SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 32 A, operating power / at AC-23 A 400 V: 11.5 kW, molded-plastic encapsulation for metric screw connection, 1 NC, 1 NO, rotary operating mechanism, red/yellow
Product family Basic Devices
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,416 Kg
Packaging Dimension 104,00 x 163,00 x 122,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209524262
UPC Not available
Commodity Code 85365080
LKZ_FDB/ CatalogID LV10.1
Product Group 5887
Group Code P360
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Given
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Model

Product Brand Name Sentron
Product Designation Switch Disconnector
Design Of The Product Emergency-Stop Switch
Display Version For Switch Position Indicator Manual
Operation 1 On - 0 Off
Type Of Switch Molded-Plastic Enclosure For Metric Threaded Joint
Design Of The Actuating Element Short Rotary Knob
Color Of The Actuating Element Red
Design Of Handle Rotary Operating Mechanism, Red/Yellow
Type Of The Driving Mechanism Motor Drive No

General Technical Data

Number Of Poles 3
Number Of Poles Note N
Size Of Switch Disconnector 2
Mechanical Service Life (Operating Cycles) Typical 100 000
Electrical Endurance (Operating Cycles)
At Ac-23 A At 690 V 6 000
Operating Frequency Maximum 50 1/H
Degree Of Pollution 3

Voltage

Insulation Voltage Rated Value 690 V
Surge Voltage Resistance Rated Value 6 Kv
Operating Voltage
At Ac Rated Value 690 V
Operating Frequency Rated Value
Minimum 50 Hz
Maximum 60 Hz

Protection Class

Protection Class Ip Ip65
Degree Of Protection Nema Rating 1, 4X, 12
Protection Class Ip On The Front Ip65

Dissipation

Power Loss [W] For Rated Value Of The Current At Ac In Hot
Operating State Per Pole1.8 W

Main Circuit

Operation Al Current
At Ac-21 At 690 V Rated Value 32 A
At Ac-21 A At 240 V Rated Value 32 A
At Ac-21 A At 400 V Rated Value 32 A
At Ac-21 A At 440 V Rated Value 32 A
At Ac-23 A At 400 V Rated Value 22 A
Operating Power
At Ac-23 A At 240 V Rated Value 6 Kw
At Ac-23 A At 400 V Rated Value 12 Kw
At Ac-23 A At 440 V Rated Value 11.5 Kw
At Ac-23 A At 690 V Rated Value 12 Kw
At Ac-3 At 240 V Rated Value 5.5 Kw
At Ac-3 At 400 V Rated Value 10 Kw
At Ac-3 At 690 V Rated Value 9.5 Kw

Auxiliary Circuit

Number Of Co Contacts For Auxiliary Contacts 0
Number Of Nc Contacts For Auxiliary Contacts 1
Number Of No Contacts For Auxiliary Contacts 1
Operating Voltage Of Auxiliary Contacts At Ac Maximum 500 V
Continuous Current Of The Auxiliary Contact Rated Value 10 A
Insulation Voltage Of The Auxiliary Switch Rated Value 500 V
Suitability
Suitability For Use
Main Switch Yes
Switch Disconnector Yes
Emergency Off Switch Yes
Safety Switch Yes
Maintenance/Repair Switch Yes

Product Details

Product Feature Can Be Locked Into Off Position Yes

Accessories

Product Extension Optional
Motor Drive No
Voltage Trigger No
Number Of Connectable Nc Contacts For Auxiliary Contacts
Attachable Maximum2
Number Of Connectable No Contacts For Auxiliary Contacts
Attachable Maximum3
Number Of Connectable Co Contacts For Auxiliary Contacts
Attachable Maximum0
Number Of Bracket Locks Maximum 3
Hasp Thickness Of The Bracket Locks 4 ... 8 Mm
Short Circuit
Conditional Short-Circuit Current With Line-Side Fuse
Protection
At 690 V By Gg Fuse Rated Value 50 Ka
Let-Through Current With Closed Switch
At 240 V For Combination Switch + Gg Fuse Maximum 4.5 Ka
At 440 V For Combination Switch + Gg Fuse Maximum 4.5 Ka
At 690 V For Combination Switch + Gg Fuse Maximum
Permissible5 Ka
I2T Value With Closed Switch
At 240 V For Combination Switch + Gg Fuse Maximum 9 Ka2.S
At 440 V For Combination Switch + Gg Fuse Maximum 9 Ka2.S
At 690 V For Combination Switch + Gg Fuse Maximum 9 Ka2.S
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit Required Fuse Gl/Gg: 40 A
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse Gl/Gg: 10 A
Operation Al Current Of Upstream Fuse Rated Value 40 A
According Ul
Operation Al Current At Ac According To Ul 508/Ul 60947-4-1
Rated Value32 A
Operating Voltage At Ac At 50/60 Hz According To Ul 508/Ul
60947-4-1 Rated Value600 V
Active Power [Hp] At Ac At 480 V According To Ul 508/Ul
60947-4-1 Rated Value20
Active Power [Hp] At Ac At 600 V According To Ul 508/Ul 20
60947-4-1 Rated Value
Short-Time Withstand Current (Sccr) At 600 V According To
Ul 508/Ul 60947-4-15 Ka
Continuous Current Of Upstream Fuse According To Ul Rated
Value80 A
Type Of Fuse According To Ul Rk5

Connections

Awg Number As Coded Connectable Conductor Cross
Section Solid Maximum
8
14
Type Of Connectable Conductor Cross-Sections For Copper
Conductor
Solid 1X (1,5...16Mm²)
Finely Stranded With Core End Processing 1X (1,5...10Mm²)
Stranded 1X (1,5...16Mm²)
Type Of Connectable Conductor Cross-Sections For Auxiliary
Contacts
Solid Lateral Auxiliary Switch 2X (0,75 ... 2,5Mm²), 1X 4Mm²; Front Auxiliary Switch 1X
(0,75 ... 2,5Mm²)
Finely Stranded With Core End Processing Lateral Auxiliary Switch 2X (0,75 ... 1,5Mm²), 1X 2,5Mm²; Front Auxiliary Switch 1X
2,5Mm²
Stranded Lateral Auxiliary Switch 2X (0,75 ... 2,5Mm²), 1X 4Mm²; Front Auxiliary Switch 1X
(0,75 ... 2,5Mm²)
Type Of Electrical Connection
For Main Current Circuit Box Terminal
For Auxiliary Contacts Connection Terminals

Mechanical Design

Height 152 Mm
Width 100 Mm
Depth 117 Mm
Type Of Device Fixed Mounting
Fastening Method Complete Unit In Enclosure
Fastening Method
4-Hole Front Mounting No
Front Mounting With Central Attachment Yes
Rail Mounting No
Net Weight 476 G

Ambient Temperature During Operation

Minimum -25 °C
Maximum 55 °C

Ambient Temperature During Storage

Minimum -25 °C
Maximum 55 °C

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible