Description for 3NP1113-2BC20 Siemens

3NP1113-2BC20 Siemens - SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH000 narrow, 125 A, for busbar systems 60 mm, box terminal, cable outlet upwards Cover level 32/60/70 mm

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£63.63 Exc. VAT
£76.36 Inc. VAT

Product

Article Number (Market Facing Number) 3NP1113-2BC20
Product Description SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH000 narrow, 125 A, for busbar systems 60 mm, box terminal, cable outlet upwards Cover level 32/60/70 mm
Product family SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,745 Kg
Packaging Dimension 146,00 x 226,00 x 106,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4001869599588
UPC Not available
Commodity Code 85365080
LKZ_FDB/ CatalogID LV10
Product Group 5863
Group Code P360
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 29.01.2021
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Model

Product Designation Fuse Switch Disconnector
Busbar Design Busbar Thickness 5 Or 10 Mm
Design Of The Safety Monitoring Without
Design Of The Load Switch Strip Form No
Type Of The Driving Mechanism Motor Drive No

General Technical Data

Number Of Poles 3
Type Of Device For 60 Mm Busbar Systems
Size Of Disconnecting Link 000
Size Of Fuse Link Nh000
Let-Through Current With Closed Switch Maximum 15 Ka
Mechanical Service Life (Operating Cycles) Typical 2 000
I2T Value With Closed Switch Maximum 150 Ka2.S
Power Factor
At Ac-22 B 0.65
At Ac-23 B 0.45
Fuse System Lv Hrc Fuse
Degree Of Pollution 2

Voltage

Insulation Voltage
Rated Value 800 V
With Degree Of Pollution 2 At Ac Rated Value 800 V
Power Factor At Ac-21 B 0.95
Surge Voltage Resistance Rated Value 6 Kv
Operation Al Current
At 35 °C Rated Value 125 A
At 40 °C Rated Value 125 A
At 45 °C Rated Value 125 A
At 50 °C Rated Value 125 A
At 55 °C Rated Value 125 A
At Ac-21 B At 240 V Rated Value 125 A
At Ac-21 B At 400 V Rated Value 125 A
At Ac-21 B At 500 V Rated Value 125 A
At Ac-21 B At 690 V Rated Value 80 A
At Ac-22 B At 240 V Rated Value 125 A
At Ac-22 B At 400 V Rated Value 125 A
At Ac-22 B At 500 V Rated Value 125 A
Let-Through Current With High-Speed Activation Maximum
Permissible10 Ka
Operating Voltage
At Ac Rated Value Maximum 690 V

Protection Class

Protection Class Ip
With Closed Switch With Cover Or Cable Lug Cover Ip30
With Closed Switch Without Cover Or Cable Lug Cover Ip30
Open Ip10

Dissipation

Power Loss [W]
With Conventional Rated Thermal Current Without Fuse Per
Pole4.6 W
With Conventional Rated Thermal Current Without Fuse Per
Device13.6 W
For Rated Value Of The Current At Ac In Hot Operating State
Per Pole13.6 W
Of The Fuse Per Fuse Maximum 9 W

Main Circuit

Operation Al Current
Rated Value 125 A

Auxiliary Circuit

Number Of Co Contacts For Auxiliary Contacts 0
Number Of Nc Contacts For Auxiliary Contacts 0
Number Of No Contacts For Auxiliary Contacts 0
Suitability
Suitability For Use
Main Switch No
Switch Disconnector Yes
Emergency Off Switch No
Safety Switch Yes
Maintenance/Repair Switch Yes

Product Details

Product Function Phase Failure Monitoring No

Product Component

Undervoltage Release No
Undervoltage Release With Leading Contact No
Product Feature Sealable Yes
Product Extension Auxiliary Switch Yes
Product Extension Optional
Locking Capability Yes
Phase Failure Monitoring No
Fuse Monitoring No
Voltage Trigger No
Overvoltage Protection Monitoring No

Product Function

Product Function Overvoltage Protection Monitoring No
Short Circuit
Conditional Short-Circuit Current (Iq)
At Ac At 240 V With High-Speed Activation Rated Value 80 Ka
At Ac At 500 V With High-Speed Activation Rated Value 80 Ka
At Ac At 690 V With High-Speed Activation Rated Value 80 Ka
With Closed Switch At Ac At 240 V Rated Value 80 Ka
With Closed Switch At Ac At 500 V Rated Value 80 Ka
With Closed Switch At Ac At 690 V Rated Value 80 Ka

Connections

Arrangement Of Electrical Connectors For Main Current Circuit Other
Connectable Conductor Cross-Section For Main Contacts
Solid Or Stranded Minimum 1.5 Mm²
Solid Or Stranded Maximum 50 Mm²
Finely Stranded With Core End Processing Minimum 1.5 Mm²
Finely Stranded With Core End Processing Maximum 35 Mm²
Stranded Minimum 16 Mm²
Stranded Maximum 50 Mm²

Tightening Torque With Screw-Type Terminals

Minimum 4 N·M
Maximum 5 N·M
Type Of Connectable Conductor Cross-Sections Of The Laminated
Conductors Maximum6 X (9 X 0.8) Mm
Type Of Connection Technology Box Terminal

Mechanical Design

Height 208 Mm
Width 53 Mm
Width Of The Busbar
Minimum 12 Mm
Maximum 30 Mm
Depth 129 Mm
Fastening Method Busbar
Fastening Method
Floor Mounting No
Rail Mounting Yes
Mounting Position Horizontal/Vertical
Busbar Center-To-Center Spacing 60 Mm
Net Weight 0.597 Kg

Ambient Temperature During Operation

Minimum -25 °C
Maximum 70 °C

Ambient Temperature During Storage

Minimum -50 °C
Maximum 80 °C
Certificates
Reference Code According To Iec 81346-2 Q