This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3RH1140-1MB40

3RH1140-1MB40 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RH1140-1MB40 Siemens

3RH1140-1MB40 Siemens - Screw terminal size S00 24 V DC extended operating range !!! Phased-out product !!! Successor is SIRIUS 3RH2

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RH1140-1MB40
Product Description Screw terminal size S00 24 V DC extended operating range !!! Phased-out product !!! Successor is SIRIUS 3RH2
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2017
Notes Product is no longer available Sucessor:www.siemens.com/conversion-tool If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 0,258 Kg
Packaging Dimension 50,00 x 63,50 x 77,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209365537
UPC Not available
Commodity Code 85364190
LKZ_FDB/ CatalogID CC-IC10
Product Group 3700
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

General Technical Data

Size Of Contactor S00
Product Extension Auxiliary Switch No
Insulation Voltage With Degree Of Pollution 3 At Ac Rated Value 690 V
Degree Of Pollution 3
Surge Voltage Resistance Rated Value 6 Kv
Protection Class Ip On The Front Ip20
Shock Resistance 10G / 5 Ms And 5G / 10 Ms
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 30 000 000
Reference Code According To Iec 81346-2 K
Substance Prohibitance (Date) 07/01/2006
Weight 0.258 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +40 °C
During Storage -55 ... +80 °C
During Transport -55 ... +80 °C
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 24 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.85
Full-Scale Value 2.15
Closing Power Of Magnet Coil At Dc 1.4 W
Holding Power Of Magnet Coil At Dc 1.4 W
Auxiliary Circuit
Number Of Nc Contacts For Auxiliary Contacts 0
Instantaneous Contact 0
Delayed Switching 0
Lagging Switching 0
Make-Before-Break Switching 0
Number Of No Contacts For Auxiliary Contacts 4
Instantaneous Contact 4
Delayed Switching 0
Leading Contact 0
Make-Before-Break Switching 0
Number Of Co Contacts
For Auxiliary Contacts 0
Of Auxiliary Contacts Instantaneous Contact 0
Identification Number And Letter For Switching Elements 40 E
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 6 A
At 400 V Rated Value 3 A
At 500 V Rated Value 2 A
At 690 V Rated Value 1 A
Operation Al Current At 1 Current Path At Dc-12
At 24 V Rated Value 10 A
At 110 V Rated Value 3 A
At 220 V Rated Value 1 A
Operation Al Current At 1 Current Path At Dc-13
At 24 V Rated Value 10 A
At 110 V Rated Value 1 A
At 220 V Rated Value 0.27 A
Contact Reliability Of Auxiliary Contacts 1 Faulty Switching Per 100 Million (17 V, 1 Ma)
Short-Circuit Protection
Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary
Switch Requiredfuse Gl/Gg: 10 A
Installation/ Mounting/ Dimensions
Mounting Position +/-180° Rotation Possible On Vertical Mounting Surface; Can Be Tilted Forward And
Backward By +/- 22.5° On Vertical Mounting Surface
Fastening Method Screw And Snap-On Mounting
Height 57.5 Mm
Width 45 Mm
Depth 72 Mm
Required Spacing With Side-By-Side Mounting At The Side 0 Mm

Connections/ Terminals

Type Of Electrical Connection For Auxiliary And Control Circuit Screw-Type Terminals
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 2.5 Mm²), 2X 4 Mm²
— Finely Stranded With Core End Processing 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (20 ... 16), 2X (18 ... 14), 1X 12
Safety Related Data
Proportion Of Dangerous Failures
With Low Demand Rate According To Sn 31920 40 %
With High Demand Rate According To Sn 31920 75 %
B10 Value With High Demand Rate According To Sn 31920 1 000 000; With 0.3 X Ie
Iec 61508
T1 Value
For Proof Test Interval Or Service Life According To Iec
6150820 A
Electrical Safety
Touch Protection Against Electrical Shock Finger-Safe

Documentation

Looking for a specific part?