3RK1323-6BS74-3AA0 Siemens - Motor starter ECOFAST AS-Interface Electronic switching Electronic/thermal Overload protection AC-3, up to 1.1 kW / 400 V 0.30 A...3.00 A without brake contact 4 DI 24 V DC Han Q4/2 - Han 10E Connection with touch protection

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RK1323-6BS74-3AA0
Product Description Motor starter ECOFAST AS-Interface Electronic switching Electronic/thermal Overload protection AC-3, up to 1.1 kW / 400 V 0.30 A...3.00 A without brake contact 4 DI 24 V DC Han Q4/2 - Han 10E Connection with touch protection
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 31.07.2019
Notes Product is no longer available Sucessor:www.siemens.com/conversion-tool If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 30 Day/Days
Net Weight (kg) 1,900 Kg
Packaging Dimension 145,00 x 300,00 x 135,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209613089
UPC Not available
Commodity Code 85365080
LKZ_FDB/ CatalogID CC-IC10
Product Group 4963
Group Code R711
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Main Circuit

Number Of Poles For Main Current Circuit 3
Design Of The Switching Contact Solid-State
Adjustable Current Response Value Current Of The Current-
Dependent Overload Release0.3 ... 3 A
Type Of The Motor Protection Full Motor Protection
Type Of Voltage Dc
Operating Voltage Rated Value 400 ... 500 V
Operation Al Current
At Ac-3 At 400 V Rated Value 3 A
Operating Power At Ac-3 At 400 V Rated Value 1 100 W
Operating Power For 3-Phase Motors At 400 V At 50 Hz 0.06 ... 1.1 Kw

Product Function

Digital Inputs Parameterizable Yes
Digital Outputs Parameterizable No
Number Of Digital Inputs 4
Number Of Sockets
For Digital Output Signals 0
For Digital Input Signals 2
Supply Voltage 1 At Dc 30 ... 30 V
Supply Voltage 1 At Dc Rated Value
Minimum Permissible 26.5 V
Maximum Permissible 31.6 V
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 20.4 ... 28.8 V
Control Supply Voltage 1 At Dc Rated Value 20.4 ... 28.8 V
Control Supply Voltage 1 At Dc 24 ... 24 V
Height 250 Mm
Width 130 Mm
Depth 107 Mm

Ambient Conditions

Ambient Temperature During Operation -20 ... +40 °C
Protocol Is Supported
Profibus Dp Protocol No
Profinet Protocol No
Protocol Is Supported As-Interface Protocol Yes
Type Of Electrical Connection
Of The Communication Interface Via As-I Shaped Cables With Cutting/Clamping Method
For Communication Transmission Via As-I Shaped Cables With Cutting/Clamping Method
Type Of Electrical Connection For Main Current Circuit Tab Terminals
Type Of Electrical Connection
1 For Digital Input Signals M12 Socket
2 For Digital Input Signals M12 Socket
Type Of Electrical Connection
At The Manufacturer-Specific Device Interface M12 Socket
For Device Addressing Front Addressing Socket
For Main Energy Infeed Socket According To Iso23570
For Load-Side Outgoing Feeder Socket According To Iso23570
For Supply Voltage Line-Side Via As-I Shaped Cables With Cutting/Clamping Method
For Supply Voltage Transmission Via As-I Shaped Cables With Cutting/Clamping Method

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible