3RK1395-6KS41-3AD5-Z E09 Siemens - SIRIUS motor starter M200D Technology module Reversing starter Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 180 V DC 4 DI / 2 DO Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch CES E9 via communication module 3RK1305* can be used on PROFIBUS or PROFINET Locking system CES E9

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RK1395-6KS41-3AD5-Z E09
Product Description SIRIUS motor starter M200D Technology module Reversing starter Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 180 V DC 4 DI / 2 DO Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch CES E9 via communication module 3RK1305* can be used on PROFIBUS or PROFINET Locking system CES E9
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 4,000 Kg
Packaging Dimension 287,00 x 377,00 x 221,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209928879
UPC Not available
Commodity Code 85371098
LKZ_FDB/ CatalogID CC-IC10
Product Group 3722
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

On-Site Operation Yes
Control Circuit Interface To Parallel Wiring No
Insulation Voltage Rated Value 500 V
Degree Of Pollution 3
Surge Voltage Resistance Rated Value 6 000 V
Maximum Permissible Voltage For Protective Separation
Between Main And Auxiliary Circuit 400 V
Between Control And Auxiliary Circuit 24 V
Shock Resistance 12G / 11 Ms
Vibration Resistance 7 Mm / 2G
Mechanical Service Life (Operating Cycles) Of The Main Contacts
Typical10 000 000
Type Of Assignment 2
Substance Prohibitance (Date) 07/01/2006
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
2,2',6,6'-Tetrabromo-4,4'-Isopropylidenediphenol - 79-94-7
Weight 4 Kg
Product Function
Direct Start No
Reverse Starting Yes
Product Component Motor Brake Output Yes
Product Feature
Brake Control With 230 V Ac No
Brake Control With 400 V Ac No
Brake Control With 24 V Dc No
Brake Control With 180 V Dc Yes
Brake Control With 500 V Dc No
Product Extension Braking Module For Brake Control No
Product Function Short Circuit Protection Yes
Design Of Short-Circuit Protection Circuit-Breakers
Maximum Short-Circuit Current Breaking Capacity (Icu)
At 400 V Rated Value 50 000 A
At 500 V Rated Value 50 000 A
Emc Emitted Interference According To Iec 60947-1 Cispr11, Ambience A (Industrial Sector)
Emc Immunity According To Iec 60947-1 Corresponds To Degree Of Severity 3, Ambience A (Industrial Sector)

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv Network Connection / 1 Kv Control Connection
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv

Safety Related Data

Proportion Of Dangerous Failures
With Low Demand Rate According To Sn 31920 50 %
3Rk13956Ks413Ad5-Z E09
With High Demand Rate According To Sn 31920 75 %
B10 Value With High Demand Rate According To Sn 31920 1 000 000
Failure Rate [Fit] With Low Demand Rate According To Sn
31920100 Fit
Iec 61508
T1 Value For Proof Test Interval Or Service Life According To Iec
6150820 A
Electrical Safety
Touch Protection Against Electrical Shock Finger-Safe

Main Circuit

Number Of Poles For Main Current Circuit 3
Design Of The Switching Contact Electromechanical
Adjustable Current Response Value Current Of The Current-
Dependent Overload Release0.1 ... 2 A
Type Of The Motor Protection Full Motor Protection
Operating Voltage Rated Value 200 ... 440 V
Operation Al Current
At Ac At 400 V Rated Value 2 A
At Ac-3 At 400 V Rated Value 2 A
At Ac-3E At 400 V Rated Value 2 A
Operating Power
At Ac-3
— At 400 V Rated Value 1 Kw
— At 500 V Rated Value 750 W
At Ac-3E
— At 400 V Rated Value 1 Kw
— At 500 V Rated Value 0.75 Kw
Product Function
Digital Inputs Parameterizable Yes
Digital Outputs Parameterizable Yes
Number Of Digital Inputs 4
Number Of Sockets
For Digital Output Signals 2
For Digital Input Signals 4
Number Of Digital Outputs 2

Supply Voltage

Type Of Voltage Of The Supply Voltage Dc
Supply Voltage 1 At Dc 24 V
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage 1 At Dc Rated Value 20.4 ... 28.8 V
Control Supply Voltage 1 At Dc 20 ... 29 V
Control Current At Dc
In Standby Mode Of Operation 100 Ma
During Operation 600 Ma
Power Loss [W] In Auxiliary And Control Circuit
In Switching State Off With Bypass Circuit 1.9584 W
In Switching State On With Bypass Circuit 5.04 W
Response Times
On-Delay Time 85 Ms
Off-Delay Time 65 Ms
Mounting Position Vertical, Horizontal, Flat
Mounting Position Recommended Horizontal
Fastening Method Screw Fixing
Height 215 Mm
Width 294 Mm
Depth 148 Mm

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +55 °C
3Rk13956Ks413Ad5-Z E09
During Storage -40 ... +70 °C
During Transport -40 ... +70 °C
Relative Humidity During Operation 10 ... 95 %
Protocol Is Supported
Profibus Dp Protocol No
Profinet Protocol No
Design Of The Interface
As-Interface Protocol No
Profinet Protocol No
Profibus Dp Protocol No
Product Function Bus Communication Yes
Protocol Is Supported As-Interface Protocol No
Product Function Control Circuit Interface With Io Link No
Type Of Electrical Connection
For Main Current Circuit Plug According To Iso 23570, Han Q4/2
For Auxiliary And Control Circuit Connector
Type Of Electrical Connection
1 For Digital Input Signals M12 Socket
1 For Digital Output Signals M12 Socket
2 For Digital Input Signals M12 Socket
3 For Digital Input Signals M12 Socket
4 For Digital Input Signals M12 Socket
Full-Load Current (Fla) For 3-Phase Ac Motor At 480 V Rated
Value1.6 A
Yielded Mechanical Performance [Hp]
For 3-Phase Ac Motor
— At 460/480 V Rated Value 0.7 Hp
— At 575/600 V Rated Value 1 Hp
Operating Voltage At Ac At 60 Hz According To Csa And Ul
Rated Value600 V