Description for 3RP1576-2NM20 Siemens

3RP1576-2NM20 Siemens - Timing relay, electronic Phased-out product !!! For further information, please contact our sales department with star-delta (wye-delta) function 1 NO contact, delayed 1 NO contact, instantaneous 1 time range 3...60 s 200-240 V AC and 380-440 V AC Spring-type terminal

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RP1576-2NM20
Product Description Timing relay, electronic Phased-out product !!! For further information, please contact our sales department with star-delta (wye-delta) function 1 NO contact, delayed 1 NO contact, instantaneous 1 time range 3...60 s 200-240 V AC and 380-440 V AC Spring-type terminal
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2021
Notes Product is no longer available Sucessor:The preferred successor is 3RP2576-2NM20 If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 0,120 Kg
Packaging Dimension 28,50 x 89,50 x 102,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209645776
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5817
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 28.05.2009
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Component

Relay Output Yes
Semi-Conductor Output No
Product Extension Required Remote Control No
Product Extension Optional Remote Control No
Power Loss [W] Maximum 2 W
Insulation Voltage For Overvoltage Category Iii According To Iec
60664 With Degree Of Pollution 3 Rated Value500 V
Test Voltage For Isolation Test 2 Kv
Degree Of Pollution 3
Surge Voltage Resistance Rated Value 6 000 V
Shock Resistance According To Iec 60068-2-27 11G / 15 Ms
Vibration Resistance According To Iec 60068-2-6 10 ... 55 Hz / 0.35 Mm
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Electrical Endurance (Operating Cycles) At Ac-15 At 230 V
Typical100 000
Adjustable Time 3 ... 60 S
Relative Setting Accuracy Relating To Full-Scale Value 5 %
Thermal Current 5 A
Recovery Time 150 Ms
Reference Code According To Iec 81346-2 K
Relative Repeat Accuracy 1 %
Influence Of The Surrounding Temperature ±5 %
Power Supply Influence ±1 %
Substance Prohibitance (Date) 05/28/2009
Svhc Substance Name Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.12 Kg
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Ac
Control Supply Voltage 1 At Ac
At 50 Hz 200 ... 240 V
At 60 Hz 200 ... 240 V
Control Supply Voltage 2 At Ac
At 50 Hz 380 ... 440 V
At 60 Hz 380 ... 440 V
Control Supply Voltage Frequency 1 50 ... 60 Hz
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 50 Hz
Initial Value 0.85
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 60 Hz
Initial Value 0.85
Full-Scale Value 1.1
Switching Function
Switching Function
On-Delay No
On-Delay/Instantaneous Contact No
Passing Make Contact No
Passing Make Contact/Instantaneous Contact No
Off Delay No
Switching Function
Flashing Symmetrically With Interval Start/Instantaneous No
Flashing Symmetrically With Interval Start No
Flashing Symmetrically With Pulse Start/Instantaneous No
Flashing Symmetrically With Pulse Start No
Flashing Asymmetrically With Interval Start No
Flashing Asymmetrically With Pulse Start No
Switching Function
Star-Delta Circuit With Delay Time No
Star-Delta Circuit Yes
Switching Function With Control Signal
Additive On-Delay No
Passing Break Contact No
Passing Break Contact/Instantaneous No
Off Delay No
Off Delay/Instantaneous No
Pulse Delayed No
Pulse Delayed/Instantaneous No
Pulse-Shaping No
Pulse-Shaping/Instantaneous No
Additive On-Delay/Instantaneous No
On-Delay/Off-Delay/Instantaneous No
Passing Make Contact No
Passing Make Contact/Instantaneous Contact No
Switching Function Of Interval Relay With Control Signal
Retrotriggerable With Deactivated Control
Signal/Instantaneous Contactno
Retrotriggerable With Switched-On Control Signal No
Retrotriggerable With Switched-On Control
Signal/Instantaneous Contactno
Retriggerable With Deactivated Control Signal No
Short-Circuit Protection
Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary
Switch Requiredfuse Gl/Gg: 4 A

Auxiliary Circuit

Material Of Switching Contacts Agsno2
Number Of Nc Contacts
Delayed Switching 0
Instantaneous Contact 0
Number Of No Contacts
Delayed Switching 1
Instantaneous Contact 1
Number Of Co Contacts
Delayed Switching 0
Instantaneous Contact 0
Operation Al Current Of Auxiliary Contacts At Ac-15
At 24 V 3 A
At 250 V 3 A
Operation Al Current Of Auxiliary Contacts At Dc-13
At 24 V 1 A
At 125 V 0.2 A
At 250 V 0.1 A
Operating Frequency With 3Rt2 Contactor Maximum 5 000 1/H
Contact Reliability Of Auxiliary Contacts One Incorrect Switching Operation Of 100 Million Switching Operations (17 V, 5
Ma)
Contact Rating Of Auxiliary Contacts According To Ul R300 / B300

Product Function

Non-Volatile No

Electromagnetic Compatibility

Emc Emitted Interference According To Iec 61812-1 En 61000-6-4(3)
Emc Immunity According To Iec 61812-1 En 61000-6-2

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv Network Connection / 1 Kv Control Connection
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 4 Kv Contact Discharge / 8 Kv Air Discharge

Safety Related Data

Category According To En 954-1 None
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Type Of Insulation Basic Insulation

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuityes
Type Of Electrical Connection For Auxiliary And Control Circuit Spring-Loaded Terminals
Type Of Connectable Conductor Cross-Sections
Solid 2X (0.25 ... 1.5 Mm²)
Finely Stranded With Core End Processing 2 X (0.25 ... 1.5 Mm²)
Finely Stranded Without Core End Processing 2X (0.25 ... 1.5 Mm²)
For Awg Cables Solid 2X (24 ... 16)
For Awg Cables Stranded 2X (24 ... 16)
Connectable Conductor Cross-Section
Solid 0.3 ... 1.5 Mm²
Finely Stranded With Core End Processing 0.3 ... 1.5 Mm²
Finely Stranded Without Core End Processing 0.3 ... 1.5 Mm²
Awg Number As Coded Connectable Conductor Cross
Section
Solid 24 ... 16
Stranded 24 ... 16
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail
Height 84 Mm
Width 22.5 Mm
Depth 91 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— Downwards 0 Mm
— At The Side 0 Mm
For Grounded Parts
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— At The Side 0 Mm
— Downwards 0 Mm
For Live Parts
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— Downwards 0 Mm
— At The Side 0 Mm

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +85 °C
During Transport -40 ... +85 °C
Relative Humidity During Operation 10 ... 95 %