This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3RQ10001HB00

3RQ10001HB00 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RQ10001HB00 Siemens

3RQ10001HB00 Siemens - Positively driven coupling relay in industrial enclosure 2 NO contacts / 2 NC contacts 24 V DC SIL 2 / PL c screw terminal

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RQ1000-1HB00
Product Description Positively driven coupling relay in industrial enclosure 2 NO contacts / 2 NC contacts 24 V DC SIL 2 / PL c screw terminal
Product family SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,200 Kg
Packaging Dimension 108,00 x 37,00 x 157,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047621055411
UPC 195125208056
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 4954
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 31.05.2018
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Product Feature Protective Coating On Printed-Circuit Board No
Consumed Active Power 1.3 W
Insulation Voltage For Overvoltage Category Iii According To Iec
60664 With Degree Of Pollution 3 Rated Value300 V
Degree Of Pollution 3
Surge Voltage Resistance Rated Value 4 Kv
Shock Resistance
According To Iec 60068-2-27 11G / 15 Ms
Vibration Resistance
According To Iec 60068-2-6 10 ... 55 Hz: 0.35 Mm
Operating Frequency Maximum 360 1/H
Switching Behavior Monostable
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Thermal Current Of The Switching Element With Contacts
Maximum 5 A
Reference Code According To Iec 81346-2 K
Substance Prohibitance (Date) 05/31/2018
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
2-Methyl-1-(4-Methylthiophenyl)-2-Morpholinopropan-1-One - 71868-10-5
4,4'-Isopropylidenediphenol (Bisphenol A, Bpa) - 80-05-7
Weight 0.2 Kg

Product Function

Suitability For Operation Device Connector 3Zy12 Yes
Control Circuit/
Control Supply Voltage 1 At Dc Rated Value 24 V
Control Supply Voltage 1 At Dc 24 ... 24 V
Operating Range Factor Control Supply Voltage Rated Value At
Dc
Initial Value 0.8
Full-Scale Value 1.2
On-Delay Time
At Ac Maximum 15 Ms
At Dc Maximum 15 Ms
Off-Delay Time Maximum 35 Ms
Switching Function
Design Of The Switching Function Nc Contact And No Contact

Mechanical Data

Product Component Plug-In Socket No
Design Of The Relay Operating Mechanism Poled
Short-Circuit Protection
Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary
Switch Requiredfuse Gl/Gg: 6 A

Auxiliary Circuit

Material Of Switching Contacts Agsno2 + Au Flash
Number Of Nc Contacts For Auxiliary Contacts 2
Number Of No Contacts For Auxiliary Contacts 2
Number Of Co Contacts For Auxiliary Contacts 0
Type Of Voltage Dc

Inputs/ Outputs

Output Current Minimum 10 Ma
Ampacity Of The Output Relay At Ac-15
At 250 V At 50/60 Hz 1.5 A
Ampacity Of The Output Relay At Dc-13
At 24 V 1 A
At 125 V 0.2 A
At 250 V 0.1 A

Electromagnetic Compatibility

Emc Emitted Interference According To Iec 60947-1 Ambience A (Industrial Sector)
Emc Immunity According To Iec 60947-1 Corresponds To Degree Of Severity 3

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv (Line To Ground)
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv (Line To Line)
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 4 Kv Contact Discharging, 8 Kv Air Discharging

Safety Related Data

Product Function
Positively Driven Operation According To Iec 60947-5-1 Yes
Suitability For Use
Safety-Related Switching On No
Safety-Related Switching Off Yes
Safe State Safe Shutdown
Test Wear-Related Service Life Necessary Yes
Stop Category According To Iec 60204-1 0
Mttfd 470 A
Iec 62061
Safety Integrity Level (Sil)
According To Iec 62061 2
Iso 13849
Performance Level (Pl) According To Iso 13849-1 C
Category According To Iso 13849-1 1
Device Type According To Iso 13849-1 1
Overdimensioning According To Iso 13849-2 Necessary No
Iec 61508
Safety Integrity Level (Sil) According To Iec 61508 2
Safety Device Type According To Iec 61508-2 Type A
Pfhd With High Demand Rate According To Iec 61508 6E-7 1/H
Pfdavg With Low Demand Rate According To Iec 61508 0.002
Safe Failure Fraction (Sff) 85 %
Hardware Fault Tolerance According To Iec 61508 0
T1 Value Of Service Life According To Iec 61508 20 A

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuityes
Type Of Electrical Connection Screw Terminal
Wire Length At Dc Maximum 2 000 M
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 4 Mm²), 2X (0.5 ... 2.5 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 4 Mm²), 2X (0.5 ... 1.5 Mm²)
For Awg Cables Solid 1X (20 ... 12), 2X (20 ... 14)
Connectable Conductor Cross-Section
Solid 0.5 ... 4 Mm²
Finely Stranded With Core End Processing Maximum 4 Mm²
Finely Stranded Without Core End Processing Minimum 0.5 Mm²
Awg Number As Coded Connectable Conductor Cross
Section
Solid 12 ... 20
Stranded 12 ... 20
Tightening Torque With Screw-Type Terminals 0.6 ... 0.8 N·M
Stripped Length Of The Cable For Auxiliary And Control Contacts 10 Mm
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail
Height 100 Mm
Width 22.5 Mm
Depth 120 Mm

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +80 °C
During Transport -40 ... +80 °C
Relative Humidity During Operation 10 ... 95 %

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible