This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3RT1017-2KF42-0LA0

3RT1017-2KF42-0LA0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RT1017-2KF42-0LA0 Siemens

3RT1017-2KF42-0LA0 Siemens - Power contactor, AC-3 12 A, 5.5 kW / 400 V 110 V DC, 3-pole, Size S00 Spring-type terminal 0.7-1.25*Us with varistor for railway application !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2017-2XF42-0LA2<<

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RT1017-2KF42-0LA0
Product Description Power contactor, AC-3 12 A, 5.5 kW / 400 V 110 V DC, 3-pole, Size S00 Spring-type terminal 0.7-1.25*Us with varistor for railway application !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2017-2XF42-0LA2<<
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2019
Notes Product is no longer available Sucessor:The successor is 3RT2017-2XF42-0LA2 If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 50 Day/Days
Net Weight (kg) 0,283 Kg
Packaging Dimension 49,00 x 64,00 x 118,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209437807
UPC 754554737645
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3703
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

General Technical Data

Size Of Contactor S00
Degree Of Pollution 3
Protection Class Ip
On The Front Ip20
Of The Terminal Ip20
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 30 000 000
Of The Contactor With Added Electronically Optimized
Auxiliary Switch Block Typical5 000 000
Of The Contactor With Added Auxiliary Switch Block Typical 10 000 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 07/01/2006
Weight 0.283 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -40 ... +70 °C

Main Circuit

Number Of Poles For Main Current Circuit 3
Number Of No Contacts For Main Contacts 3
Number Of Nc Contacts For Main Contacts 0
Operation Al Current
At Ac-1 At 400 V At Ambient Temperature 40 °C Rated
Value22 A
At Ac-1
— Up To 690 V At Ambient Temperature 40 °C Rated
Value22 A
— Up To 690 V At Ambient Temperature 60 °C Rated
Value20 A
At Ac-3
— At 400 V Rated Value 12 A
At Ac-4 At 400 V Rated Value 8.5 A
Operating Power
At Ac-1
— At 400 V Rated Value 13 Kw
At Ac-2 At 400 V Rated Value 5.5 Kw
At Ac-3
— At 400 V Rated Value 5.5 Kw
— At 500 V Rated Value 5.5 Kw
— At 690 V Rated Value 5.5 Kw
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 110 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.7
Full-Scale Value 1.25
Design Of The Surge Suppressor With Varistor
Closing Power Of Magnet Coil At Dc 11 W
Holding Power Of Magnet Coil At Dc 4 W

Auxiliary Circuit

Number Of Nc Contacts For Auxiliary Contacts Instantaneous
Contact0
Number Of No Contacts For Auxiliary Contacts Instantaneous
Contact0
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 6 A
At 400 V Rated Value 3 A
Operation Al Current At Dc-12
At 60 V Rated Value 6 A
At 110 V Rated Value 3 A
At 220 V Rated Value 1 A
Operation Al Current At Dc-13
At 24 V Rated Value 10 A
At 60 V Rated Value 2 A
At 110 V Rated Value 1 A
At 220 V Rated Value 0.3 A
Contact Reliability Of Auxiliary Contacts 1 Faulty Switching Per 100 Million (17 V, 1 Ma)
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required Fuse Gl/Gg: 35 A
— With Type Of Assignment 2 Required Fuse Gl/Gg: 20 A
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse Gl/Gg: 10 A
Installation/ Mounting/ Dimensions
Fastening Method Side-By-Side Mounting Yes
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail According To Din En 50022
Height 60 Mm
Width 45 Mm
Depth 72 Mm
Required Spacing For Grounded Parts At The Side 6 Mm

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Spring-Loaded Terminals
For Auxiliary And Control Circuit Spring-Loaded Terminals
Type Of Connectable Conductor Cross-Sections For Main Contacts
Solid 2X (0.25 ... 2.5 Mm²)
Solid Or Stranded 2X (0,25 ... 2,5 Mm²)
Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
Finely Stranded Without Core End Processing 2X (0.25 ... 2.5 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 2X (0.25 ... 2.5 Mm²)
— Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
— Finely Stranded Without Core End Processing 2X (0.25 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (24 ... 14)

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible