Description for 3RT1025-3XF40-0LA2 Siemens

3RT1025-3XF40-0LA2 Siemens - Traction contactor, AC-3 17 A, 7.5 kW / 400 V 110 V DC 0.7...1.25*Us 3-pole Size S0 Spring-type terminal with electronic Control unit Integrated varistor !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2025-2XF40-0LA2<<

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RT1025-3XF40-0LA2
Product Description Traction contactor, AC-3 17 A, 7.5 kW / 400 V 110 V DC 0.7...1.25*Us 3-pole Size S0 Spring-type terminal with electronic Control unit Integrated varistor !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2025-2XF40-0LA2<<
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2018
Notes Product is no longer available Sucessor:The successor is 3RT2025-2XF40-0LA2 If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 0,645 Kg
Packaging Dimension 53,00 x 115,50 x 125,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209562912
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3704
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Contactor S0

Product Extension

Function Module For Communication No
Insulation Voltage
Of Main Circuit With Degree Of Pollution 3 Rated Value 690 V
Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value 690 V
Surge Voltage Resistance
Of Main Circuit Rated Value 6 Kv
Of Auxiliary Circuit Rated Value 6 Kv
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 10 000 000
Of The Contactor With Added Electronically Optimized
Auxiliary Switch Block Typical5 000 000
Of The Contactor With Added Auxiliary Switch Block Typical 10 000 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 05/01/2012
Svhc Substance Name Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.645 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -40 ... +70 °C

Main Circuit

Number Of Poles For Main Current Circuit 3
Number Of No Contacts For Main Contacts 3
Operation Al Current
At Ac-1
— Up To 690 V At Ambient Temperature 40 °C Rated
Value40 A
— Up To 690 V At Ambient Temperature 60 °C Rated
Value35 A
At Ac-3
— At 400 V Rated Value 17 A
At Ac-4 At 400 V Rated Value 15.5 A
Operation Al Current
At 1 Current Path At Dc-1
— At 24 V Rated Value 35 A
— At 110 V Rated Value 4.5 A
With 2 Current Paths In Series At Dc-1
— At 24 V Rated Value 35 A
— At 110 V Rated Value 35 A
With 3 Current Paths In Series At Dc-1
— At 24 V Rated Value 35 A
— At 110 V Rated Value 35 A
At 1 Current Path At Dc-3 At Dc-5
— At 24 V Rated Value 20 A
— At 110 V Rated Value 2.5 A
With 2 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 35 A
— At 110 V Rated Value 15 A
With 3 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 35 A
— At 110 V Rated Value 35 A
Operating Power
At Ac-3
— At 400 V Rated Value 7.5 Kw
— At 500 V Rated Value 10 Kw
— At 690 V Rated Value 11 Kw
Control Circuit/
Type Of Voltage Dc
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 110 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.7
Full-Scale Value 1.25
Design Of The Surge Suppressor With Varistor
Closing Power Of Magnet Coil At Dc 6 W
Holding Power Of Magnet Coil At Dc 5.4 W

Auxiliary Circuit

Number Of Nc Contacts For Auxiliary Contacts 2
Instantaneous Contact 0
Number Of No Contacts For Auxiliary Contacts 2
Instantaneous Contact 0
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 6 A
At 400 V Rated Value 3 A
Operation Al Current At Dc-12
At 60 V Rated Value 6 A
At 110 V Rated Value 3 A
At 220 V Rated Value 1 A
Operation Al Current At Dc-13
At 24 V Rated Value 10 A
At 60 V Rated Value 2 A
At 110 V Rated Value 1 A
At 220 V Rated Value 0.3 A
Ul/Csa Ratings
Yielded Mechanical Performance [Hp]
For Single-Phase Ac Motor
— At 110/120 V Rated Value 1 Hp
— At 230 V Rated Value 3 Hp
For 3-Phase Ac Motor
— At 200/208 V Rated Value 5 Hp
— At 220/230 V Rated Value 5 Hp
— At 460/480 V Rated Value 10 Hp
— At 575/600 V Rated Value 15 Hp
Short-Circuit Protection
Product Function Short Circuit Protection No
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required Fuse Gl/Gg: 63 A
— With Type Of Assignment 2 Required Fuse Gl/Gg: 25 A
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse Gl/Gg: 10 A
Installation/ Mounting/ Dimensions
Fastening Method Side-By-Side Mounting Yes
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail According To Din En 50022
Height 119 Mm
Width 45 Mm
Depth 100 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 10 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm
For Grounded Parts
— Forwards 10 Mm
— Upwards 10 Mm
— At The Side 10 Mm
— Downwards 10 Mm
For Live Parts
— Forwards 10 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Spring-Loaded Terminals
Type Of Connectable Conductor Cross-Sections For Main Contacts
Solid 2X (1 ... 2.5 Mm²), 2X (2.5 ... 6 Mm²), Max. 2X 10 Mm²
Solid Or Stranded 2X (1 ... 2,5 Mm²), 2X (2,5 ... 6 Mm²), Max. 2X 10 Mm²
Finely Stranded With Core End Processing 2X (1 ... 2.5 Mm²), 2X (2.5 ... 6 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 2X (0.25 ... 2.5 Mm²)
— Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
— Finely Stranded Without Core End Processing 2X (0.25 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (24 ... 14)
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front

Communication/ Protocol

Product Function Bus Communication No

Documentation