This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3RT1035-3XF40-0LA2

3RT1035-3XF40-0LA2 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RT1035-3XF40-0LA2 Siemens

3RT1035-3XF40-0LA2 Siemens - Traction contactor, AC-3 40 A, 18.5 kW / 400 V 110 V DC, 0.7-1.25* Us, 3-pole, Size S2 Spring-type terminal With electronic control unit Integrated varistor !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2035-3XF40-0LA2<<

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RT1035-3XF40-0LA2
Product Description Traction contactor, AC-3 40 A, 18.5 kW / 400 V 110 V DC, 0.7-1.25* Us, 3-pole, Size S2 Spring-type terminal With electronic control unit Integrated varistor !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2035-3XF40-0LA2<<
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2020
Notes Product is no longer available Sucessor:www.siemens.com/conversion-tool If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 20 Day/Days
Net Weight (kg) 1,490 Kg
Packaging Dimension 62,00 x 147,00 x 167,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209562974
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3705
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Contactor S2

Product Extension

Function Module For Communication No
Maximum Permissible Voltage For Protective Separation Between
Coil And Main Contacts According To En 60947-1400 V
Shock Resistance At Rectangular Impulse
At Dc 10G / 5 Ms, 5G / 10 Ms
Shock Resistance With Sine Pulse
At Dc 15G / 5 Ms, 8G / 10 Ms
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 10 000 000
Of The Contactor With Added Electronically Optimized
Auxiliary Switch Block Typical5 000 000
Of The Contactor With Added Auxiliary Switch Block Typical 10 000 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 05/01/2012
Svhc Substance Name Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 1.515 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -40 ... +70 °C
During Storage -55 ... +80 °C

Main Circuit

Number Of Poles For Main Current Circuit 3
Number Of No Contacts For Main Contacts 3
Number Of Nc Contacts For Main Contacts 0
Operation Al Current
At Ac-1 At 400 V At Ambient Temperature 40 °C Rated
Value60 A
At Ac-1
— Up To 690 V At Ambient Temperature 40 °C Rated
Value60 A
— Up To 690 V At Ambient Temperature 60 °C Rated
Value55 A
At Ac-3
— At 400 V Rated Value 40 A
— At 690 V Rated Value 24 A
At Ac-4 At 400 V Rated Value 35 A
Minimum Cross-Section In Main Circuit
At Maximum Ac-1 Rated Value 16 Mm²
Operation Al Current For Approx. 200000 Operating Cycles At
Ac-4
At 400 V Rated Value 18.5 A
At 690 V Rated Value 12.6 A
Operation Al Current
At 1 Current Path At Dc-1
— At 24 V Rated Value 55 A
— At 110 V Rated Value 4.5 A
With 2 Current Paths In Series At Dc-1
— At 24 V Rated Value 55 A
— At 110 V Rated Value 25 A
With 3 Current Paths In Series At Dc-1
— At 24 V Rated Value 55 A
— At 110 V Rated Value 55 A
At 1 Current Path At Dc-3 At Dc-5
— At 24 V Rated Value 35 A
— At 110 V Rated Value 2.5 A
With 2 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 55 A
— At 110 V Rated Value 25 A
With 3 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 55 A
— At 110 V Rated Value 55 A
Operating Power
At Ac-2 At 400 V Rated Value 18.5 Kw
At Ac-3
— At 230 V Rated Value 11 Kw
— At 400 V Rated Value 18.5 Kw
— At 500 V Rated Value 22 Kw
— At 690 V Rated Value 22 Kw
Operating Power For Approx. 200000 Operating Cycles At Ac-
4
At 400 V Rated Value 9.5 Kw
At 690 V Rated Value 11.4 Kw
No-Load Switching Frequency
At Dc 1 500 1/H
Operating Frequency
At Ac-1 Maximum 1 200 1/H
At Ac-2 Maximum 600 1/H
At Ac-3 Maximum 1 000 1/H
At Ac-4 Maximum 300 1/H
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 110 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.7
Full-Scale Value 1.25
Design Of The Surge Suppressor With Varistor
Closing Power Of Magnet Coil At Dc 15 W
Holding Power Of Magnet Coil At Dc 11 W
Closing Delay
At Dc 60 ... 100 Ms
Opening Delay
At Dc 20 ... 25 Ms
Arcing Time 10 ... 15 Ms

Auxiliary Circuit

Number Of Nc Contacts For Auxiliary Contacts
Instantaneous Contact 0
Number Of No Contacts For Auxiliary Contacts
Instantaneous Contact 0
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 6 A
At 400 V Rated Value 3 A
Operation Al Current At Dc-12
At 60 V Rated Value 6 A
At 110 V Rated Value 3 A
At 220 V Rated Value 1 A
Operation Al Current At Dc-13
At 24 V Rated Value 10 A
At 60 V Rated Value 2 A
At 110 V Rated Value 1 A
At 220 V Rated Value 0.3 A
Ul/Csa Ratings
Contact Rating Of Auxiliary Contacts According To Ul A600 / Q600
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required Fuse Gl/Gg: 125 A
— With Type Of Assignment 2 Required Fuse Gl/Gg: 63 A
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse Gl/Gg: 10 A
Installation/ Mounting/ Dimensions
Fastening Method Side-By-Side Mounting Yes
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail According To Din En 50022
Height 142 Mm
Width 55 Mm
Depth 130 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 10 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm
For Grounded Parts
— Forwards 10 Mm
— Upwards 10 Mm
— At The Side 10 Mm
— Downwards 10 Mm
For Live Parts
— Forwards 10 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Spring-Loaded Terminals
Type Of Connectable Conductor Cross-Sections For Main Contacts
Solid 2X (0.75 ... 16 Mm²)
Stranded 2X (0.75 ... 25 Mm²)
Solid Or Stranded 2X (0.75 ... 16 Mm²)
Finely Stranded With Core End Processing 2X (0.75 ... 16 Mm²)
Finely Stranded Without Core End Processing 2X (0.75 ... 16 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 2X (0.25 ... 2.5 Mm²)
— Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
— Finely Stranded Without Core End Processing 2X (0.25 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (24 ... 14)
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front

Documentation