3RT1054-2XF46-1LA2

3RT1054-2XF46-1LA2 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RT1054-2XF46-1LA2 Siemens

3RT1054-2XF46-1LA2 Siemens - Traction contactor, AC-3 115 A, 55 kW / 400 V Coil 110 V DC x (0.7-1.25) PLC input 24-110 V DC Auxiliary contacts 2 NO + 2 NC 3-pole size S6 Busbar connections Coil connection: Spring-type terminal Upright mounting position

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RT1054-2XF46-1LA2
Product Description power contactor, AC-3e/AC-3 115 A, 55 kW / 400 V, Uc: 110 V DC x (0.7-1.25) PLC input 24-110 V DC 3-pole, auxiliary contacts 2 NO + 2 NC drive: electronic main circuit: busbar control and auxiliary circuit: spring-loaded terminal upright mounting position
Product family Not available
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations ECCN : 9N9999 / AL : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 3,264 Kg
Packaging Dimension 196,00 x 130,00 x 183,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047621058559
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3706
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 27.02.2018
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Perfluorobutane sulfonic ... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Perfluorobutane sulfonic acid (PFBS) and its salts Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Contactor S6

Product Extension

Function Module For Communication No
Auxiliary Switch Yes
Power Loss [W] For Rated Value Of The Current
At Ac In Hot Operating State 21 W
At Ac In Hot Operating State Per Pole 7 W
Type Of Calculation Of Power Loss Depending On Pole Quadratic
Insulation Voltage
Of Main Circuit With Degree Of Pollution 3 Rated Value 1 000 V
Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value 500 V
Surge Voltage Resistance
Of Main Circuit Rated Value 8 Kv
Of Auxiliary Circuit Rated Value 6 Kv
Maximum Permissible Voltage For Protective Separation Between
Coil And Main Contacts According To En 60947-1690 V
Shock Resistance For Railway Applications According To En 61373 Category 1, Class B
Shock Resistance At Rectangular Impulse
At Dc 8,5G / 5 Ms, 4,2G / 10 Ms
Shock Resistance With Sine Pulse
At Dc 13,4G / 5 Ms, 6,5G / 10 Ms
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 10 000 000
Of The Contactor With Added Electronically Optimized
Auxiliary Switch Block Typical5 000 000
Of The Contactor With Added Auxiliary Switch Block Typical 10 000 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 02/27/2018
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
Perfluorobutane Sulfonic Acid (Pfbs) And Its Salts - -
Weight 3.264 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -40 ... +70 °C
During Storage -55 ... +80 °C
Relative Humidity Minimum 10 %
Relative Humidity At 55 °C According To Iec 60068-2-30
Maximum 95 %

Main Circuit

Number Of Poles For Main Current Circuit 3
Number Of No Contacts For Main Contacts 3
Number Of Nc Contacts For Main Contacts 0
Operating Voltage
At Ac-3 Rated Value Maximum 1 000 V
At Ac-3E Rated Value Maximum 1 000 V
Operation Al Current
At Ac-1 At 400 V At Ambient Temperature 40 °C Rated
Value160 A
At Ac-1
— Up To 690 V At Ambient Temperature 40 °C Rated
Value160 A
— Up To 690 V At Ambient Temperature 60 °C Rated
Value140 A
— Up To 1000 V At Ambient Temperature 60 °C Rated
Value80 A
At Ac-2 At 400 V Rated Value 115 A
At Ac-3
— At 400 V Rated Value 115 A
— At 500 V Rated Value 115 A
— At 690 V Rated Value 115 A
— At 1000 V Rated Value 53 A
At Ac-3E
— At 400 V Rated Value 115 A
— At 500 V Rated Value 115 A
— At 690 V Rated Value 115 A
— At 1000 V Rated Value 53 A
At Ac-4 At 400 V Rated Value 97 A
Minimum Cross-Section In Main Circuit
At Maximum Ac-1 Rated Value 70 Mm²
At Maximum Ith Rated Value 70 Mm²
Operation Al Current For Approx. 200000 Operating Cycles At
Ac-4
At 400 V Rated Value 54 A
At 690 V Rated Value 48 A
Operation Al Current
At 1 Current Path At Dc-1
— At 24 V Rated Value 160 A
— At 110 V Rated Value 18 A
— At 220 V Rated Value 3.4 A
— At 440 V Rated Value 0.8 A
— At 600 V Rated Value 0.5 A
With 2 Current Paths In Series At Dc-1
— At 24 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 20 A
— At 440 V Rated Value 3.2 A
— At 600 V Rated Value 1.6 A
With 3 Current Paths In Series At Dc-1
— At 24 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 160 A
— At 440 V Rated Value 11.5 A
— At 600 V Rated Value 4 A
At 1 Current Path At Dc-3 At Dc-5
— At 24 V Rated Value 160 A
— At 110 V Rated Value 2.5 A
— At 220 V Rated Value 0.6 A
— At 440 V Rated Value 0.17 A
— At 600 V Rated Value 0.12 A
With 2 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 2.5 A
— At 440 V Rated Value 0.65 A
— At 600 V Rated Value 0.37 A
With 3 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 160 A
— At 440 V Rated Value 1.4 A
— At 600 V Rated Value 0.75 A
Operating Power
At Ac-2 At 400 V Rated Value 55 Kw
At Ac-3
— At 230 V Rated Value 37 Kw
— At 400 V Rated Value 55 Kw
— At 500 V Rated Value 75 Kw
— At 690 V Rated Value 110 Kw
— At 1000 V Rated Value 75 Kw
At Ac-3E
— At 230 V Rated Value 37 Kw
— At 400 V Rated Value 55 Kw
— At 500 V Rated Value 75 Kw
— At 690 V Rated Value 110 Kw
— At 1000 V Rated Value 75 Kw
Operating Power For Approx. 200000 Operating Cycles At Ac-
4
At 400 V Rated Value 29 Kw
At 690 V Rated Value 48 Kw
Short-Time Withstand Current In Cold Operating State Up To
40 °C
Limited To 1 S Switching At Zero Current Maximum 2 565 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 5 S Switching At Zero Current Maximum 1 654 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 10 S Switching At Zero Current Maximum 1 170 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 30 S Switching At Zero Current Maximum 729 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 60 S Switching At Zero Current Maximum 572 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
No-Load Switching Frequency
At Dc 1 000 1/H
Operating Frequency
At Ac-1 Maximum 800 1/H
At Ac-2 Maximum 400 1/H
At Ac-3 Maximum 1 000 1/H
At Ac-3E Maximum 1 000 1/H
At Ac-2 At Ac-3E Maximum 400 1/H
At Ac-4 Maximum 130 1/H
Operating Frequency
At Dc-1 Maximum 400 1/H
At Dc-3 Maximum 500 1/H
At Dc-5 Maximum 500 1/H
Ratings For Railway Applications
Thermal Current (Ith) Up To 690 V
Up To 40 °C According To Iec 60077 Rated Value 160 A
Up To 70 °C According To Iec 60077 Rated Value 120 A
Control Circuit/
Type Of Voltage Dc
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 110 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.7
Full-Scale Value 1.25
Consumed Current At Plc-Control Input According To Iec
60947-1 Maximum2 Ma
Voltage At Plc-Control Input 24 ... 110 V
Design Of The Surge Suppressor With Varistor
Closing Power Of Magnet Coil At Dc 320 W
Holding Power Of Magnet Coil At Dc 2.8 W
Closing Delay
At Dc 35 ... 75 Ms
Opening Delay
At Dc 80 ... 90 Ms
Arcing Time 10 ... 15 Ms
Control Version Of The Switch Operating Mechanism Plc-In Or Standard A1 - A2 (Adjustable)

Auxiliary Circuit

Number Of Nc Contacts For Auxiliary Contacts 2
Instantaneous Contact 2
Number Of No Contacts For Auxiliary Contacts 2
Instantaneous Contact 2
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 6 A
At 400 V Rated Value 3 A
At 500 V Rated Value 2 A
Operation Al Current At Dc-12
At 24 V Rated Value 10 A
At 48 V Rated Value 6 A
At 60 V Rated Value 6 A
At 110 V Rated Value 3 A
At 125 V Rated Value 2 A
At 220 V Rated Value 1 A
At 600 V Rated Value 0.15 A
Operation Al Current At Dc-13
At 24 V Rated Value 6 A
At 48 V Rated Value 2 A
At 60 V Rated Value 2 A
At 110 V Rated Value 1 A
At 125 V Rated Value 0.9 A
At 220 V Rated Value 0.3 A
At 600 V Rated Value 0.1 A
Ul/Csa Ratings
Full-Load Current (Fla) For 3-Phase Ac Motor
At 480 V Rated Value 124 A
At 600 V Rated Value 125 A
Yielded Mechanical Performance [Hp]
For Single-Phase Ac Motor
— At 230 V Rated Value 25 Hp
For 3-Phase Ac Motor
— At 200/208 V Rated Value 40 Hp
— At 220/230 V Rated Value 50 Hp
— At 460/480 V Rated Value 100 Hp
— At 575/600 V Rated Value 125 Hp
Contact Rating Of Auxiliary Contacts According To Ul A600 / Q600
Short-Circuit Protection
Product Function Short Circuit Protection No
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required Gg: 355 A (690 V, 100 Ka)
— With Type Of Assignment 2 Required Gg: 315 A (690 V, 100 Ka), Am: 200 A (690 V, 50 Ka), Bs88: 250 A (415 V, 50
Ka)
For Short-Circuit Protection Of The Auxiliary Switch Required Gg: 10 A (500 V, 1 Ka)
Installation/ Mounting/ Dimensions
Mounting Position Standing, On Horizontal Mounting Surface
Fastening Method Side-By-Side Mounting Yes
Fastening Method Screw Fixing
Height 172 Mm
Width 120 Mm
Depth 170 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 20 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm
For Grounded Parts
— Forwards 20 Mm
— Upwards 10 Mm
— At The Side 10 Mm
— Downwards 10 Mm
For Live Parts
— Forwards 20 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Spring-Loaded Terminals
Width Of Connection Bar 17 Mm
Thickness Of Connection Bar 3 Mm
Diameter Of Holes 9 Mm
Number Of Holes 1
Type Of Connectable Conductor Cross-Sections For Main Contacts
Solid Or Stranded 2X (25 ... 120 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 2X (0.25 ... 2.5 Mm²)
— Solid Or Stranded 2X (0,25 ... 2,5 Mm²)
— Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
— Finely Stranded Without Core End Processing 2X (0.25 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (24 ... 14)
Awg Number As Coded Connectable Conductor Cross
Section
For Auxiliary Contacts 24 ... 14

Product Function

Mirror Contact According To Iec 60947-4-1 Yes
Positively Driven Operation According To Iec 60947-5-1 No
Suitable For Safety Function Yes
Suitability For Use Safety-Related Switching Off Yes; Safety-Related Disconnection Via A1 A2
Service Life Maximum 20 A
Test Wear-Related Service Life Necessary Yes
Proportion Of Dangerous Failures
With Low Demand Rate According To Sn 31920 40 %
With High Demand Rate According To Sn 31920 73 %
B10 Value With High Demand Rate According To Sn 31920 1 000 000
Failure Rate [Fit] With Low Demand Rate According To Sn
31920100 Fit
Iso 13849
Device Type According To Iso 13849-1 3
Overdimensioning According To Iso 13849-2 Necessary Yes
Iec 61508
Safety Device Type According To Iec 61508-2 Type A
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip00; Ip20 With Box Terminal/Cover
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front With Box Terminal/Cover

Communication/ Protocol

Product Function Bus Communication No