Siemens

3RT1056-6AF36-0UA0

3RT1056-6AF36-0UA0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RT1056-6AF36-0UA0 Siemens

3RT1056-6AF36-0UA0 Siemens - contactor, 100HP, 460 / 575 V AC (50...60 Hz) / DC operation 110 ... 127 V AC/DC auxiliary contacts 2 NO + 2 NC 3-pole, frame size S6 busbar connections drive: conventional NEMA size 4

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RT1056-6AF36-0UA0
Product Description contactor, 100HP, 460 / 575 V AC (50...60 Hz) / DC operation 110 ... 127 V AC/DC auxiliary contacts 2 NO + 2 NC 3-pole, frame size S6 busbar connections drive: conventional NEMA size 4
Product family SIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 3,369 Kg
Packaging Dimension 190,00 x 129,00 x 181,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209590595
UPC 754554848969
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3706
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Contactor S6

Product Extension

Function Module For Communication No
Auxiliary Switch Yes
Power Loss [W] For Rated Value Of The Current
At Ac In Hot Operating State 39 W
At Ac In Hot Operating State Per Pole 13 W
Without Load Current Share Typical 5.2 W
Type Of Calculation Of Power Loss Depending On Pole Quadratic
Insulation Voltage
Of Main Circuit With Degree Of Pollution 3 Rated Value 1 000 V
Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value 500 V
Surge Voltage Resistance
Of Main Circuit Rated Value 8 Kv
Of Auxiliary Circuit Rated Value 6 Kv
Maximum Permissible Voltage For Protective Separation Between
Coil And Main Contacts According To En 60947-1690 V
Shock Resistance At Rectangular Impulse
At Ac 8,5G / 5 Ms, 4,2G / 10 Ms
At Dc 8,5G / 5 Ms, 4,2G / 10 Ms
Shock Resistance With Sine Pulse
At Ac 13,4G / 5 Ms, 6,5G / 10 Ms
At Dc 13,4G / 5 Ms, 6,5G / 10 Ms
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 10 000 000
Of The Contactor With Added Electronically Optimized
Auxiliary Switch Block Typical5 000 000
Of The Contactor With Added Auxiliary Switch Block Typical 10 000 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 05/01/2012
Svhc Substance Name Lead - 7439-92-1
Weight 3.369 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -55 ... +80 °C
Relative Humidity Minimum 10 %
Relative Humidity At 55 °C According To Iec 60068-2-30
Maximum 95 %

Main Circuit

Number Of Poles For Main Current Circuit 3
Number Of No Contacts For Main Contacts 3
Operating Voltage
At Ac-3 Rated Value Maximum 1 000 V
At Ac-3E Rated Value Maximum 1 000 V
Operation Al Current
At Ac-1 At 400 V At Ambient Temperature 40 °C Rated
Value215 A
At Ac-1
— Up To 690 V At Ambient Temperature 40 °C Rated
Value215 A
— Up To 690 V At Ambient Temperature 60 °C Rated
Value185 A
— Up To 1000 V At Ambient Temperature 40 °C Rated
Value100 A
— Up To 1000 V At Ambient Temperature 60 °C Rated
Value100 A
At Ac-3
— At 400 V Rated Value 135 A
— At 500 V Rated Value 185 A
— At 690 V Rated Value 170 A
— At 1000 V Rated Value 65 A
At Ac-3E
— At 400 V Rated Value 185 A
— At 500 V Rated Value 185 A
— At 690 V Rated Value 170 A
— At 1000 V Rated Value 65 A
At Ac-4 At 400 V Rated Value 160 A
At Ac-5A Up To 690 V Rated Value 189 A
At Ac-5B Up To 400 V Rated Value 153 A
At Ac-6A
— Up To 230 V For Current Peak Value N=20 Rated Value 157 A
— Up To 400 V For Current Peak Value N=20 Rated Value 157 A
— Up To 500 V For Current Peak Value N=20 Rated Value 157 A
— Up To 690 V For Current Peak Value N=20 Rated Value 157 A
— Up To 1000 V For Current Peak Value N=20 Rated
Value65 A
At Ac-6A
— Up To 230 V For Current Peak Value N=30 Rated Value 105 A
— Up To 400 V For Current Peak Value N=30 Rated Value 105 A
— Up To 500 V For Current Peak Value N=30 Rated Value 105 A
— Up To 690 V For Current Peak Value N=30 Rated Value 105 A
— Up To 1000 V For Current Peak Value N=30 Rated
Value65 A
Minimum Cross-Section In Main Circuit At Maximum Ac-1 Rated
Value95 Mm²
Operation Al Current For Approx. 200000 Operating Cycles At
Ac-4
At 400 V Rated Value 81 A
At 690 V Rated Value 65 A
Operation Al Current
At 1 Current Path At Dc-1
— At 24 V Rated Value 160 A
— At 60 V Rated Value 160 A
— At 110 V Rated Value 18 A
— At 220 V Rated Value 3.4 A
— At 440 V Rated Value 0.8 A
— At 600 V Rated Value 0.5 A
With 2 Current Paths In Series At Dc-1
— At 24 V Rated Value 160 A
— At 60 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 20 A
— At 440 V Rated Value 3.2 A
— At 600 V Rated Value 1.6 A
With 3 Current Paths In Series At Dc-1
— At 24 V Rated Value 160 A
— At 60 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 160 A
— At 440 V Rated Value 11.5 A
— At 600 V Rated Value 4 A
At 1 Current Path At Dc-3 At Dc-5
— At 24 V Rated Value 160 A
— At 60 V Rated Value 7.5 A
— At 220 V Rated Value 0.6 A
— At 440 V Rated Value 0.17 A
— At 600 V Rated Value 0.12 A
With 2 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 160 A
— At 60 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 2.5 A
— At 440 V Rated Value 0.65 A
— At 600 V Rated Value 0.37 A
With 3 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 160 A
— At 60 V Rated Value 160 A
— At 110 V Rated Value 160 A
— At 220 V Rated Value 160 A
— At 440 V Rated Value 1.4 A
— At 600 V Rated Value 0.75 A
Operating Power
At Ac-3
— At 230 V Rated Value 55 Kw
— At 400 V Rated Value 90 Kw
— At 500 V Rated Value 132 Kw
— At 690 V Rated Value 160 Kw
— At 1000 V Rated Value 90 Kw
At Ac-3E
— At 230 V Rated Value 55 Kw
— At 400 V Rated Value 90 Kw
— At 500 V Rated Value 132 Kw
— At 690 V Rated Value 160 Kw
— At 1000 V Rated Value 90 Kw
Operating Power For Approx. 200000 Operating Cycles At Ac-
4
At 400 V Rated Value 45 Kw
At 690 V Rated Value 65 Kw
Operating Apparent Power At Ac-6A
Up To 230 V For Current Peak Value N=20 Rated Value 60 000 Kva
Up To 400 V For Current Peak Value N=20 Rated Value 100 000 Va
Up To 500 V For Current Peak Value N=20 Rated Value 130 000 Va
Up To 690 V For Current Peak Value N=20 Rated Value 180 000 Va
Up To 1000 V For Current Peak Value N=20 Rated Value 110 000 Va
Operating Apparent Power At Ac-6A
Up To 230 V For Current Peak Value N=30 Rated Value 40 000 Va
Up To 400 V For Current Peak Value N=30 Rated Value 70 000 Va
Up To 500 V For Current Peak Value N=30 Rated Value 90 000 Va
Up To 690 V For Current Peak Value N=30 Rated Value 120 000 Va
Up To 1000 V For Current Peak Value N=30 Rated Value 110 000 Va
Short-Time Withstand Current In Cold Operating State Up To
40 °C
Limited To 1 S Switching At Zero Current Maximum 2 900 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 5 S Switching At Zero Current Maximum 2 084 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 10 S Switching At Zero Current Maximum 1 480 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 30 S Switching At Zero Current Maximum 968 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
Limited To 60 S Switching At Zero Current Maximum 801 A; Use Minimum Cross-Section Acc. To Ac-1 Rated Value
No-Load Switching Frequency
At Ac 2 000 1/H
At Dc 2 000 1/H
Operating Frequency
At Ac-1 Maximum 800 1/H
At Ac-2 Maximum 300 1/H
At Ac-3 Maximum 750 1/H
At Ac-3E Maximum 750 1/H
At Ac-4 Maximum 130 1/H
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Ac/Dc
Control Supply Voltage At Ac
At 50 Hz Rated Value 110 ... 127 V
At 60 Hz Rated Value 110 ... 127 V
Control Supply Voltage At Dc Rated Value 110 ... 127 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.8
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Ac
At 50 Hz 0.8 ... 1.1
At 60 Hz 0.8 ... 1.1
Design Of The Surge Suppressor With Varistor
Apparent Pick-Up Power
At Minimum Rated Control Supply Voltage At Ac
— At 50 Hz 250 Va
— At 60 Hz 250 Va
At Maximum Rated Control Supply Voltage At Ac
— At 60 Hz 300 Va
— At 50 Hz 300 Va
Apparent Pick-Up Power Of Magnet Coil At Ac
At 50 Hz 300 Va
At 60 Hz 300 Va
Inductive Power Factor With Closing Power Of The Coil
At 50 Hz 0.9
At 60 Hz 0.9
Apparent Holding Power
At Minimum Rated Control Supply Voltage At Dc 4.3 Va
At Maximum Rated Control Supply Voltage At Dc 5.2 Va
Apparent Holding Power
At Minimum Rated Control Supply Voltage At Ac
— At 50 Hz 4.8 Va
— At 60 Hz 4.8 Va
At Maximum Rated Control Supply Voltage At Ac
— At 50 Hz 5.8 Va
— At 60 Hz 5.8 Va
Inductive Power Factor With The Holding Power Of The Coil
At 50 Hz 0.8
At 60 Hz 0.8
Closing Power Of Magnet Coil At Dc 360 W
Holding Power Of Magnet Coil At Dc 5.2 W
Closing Delay
At Ac 20 ... 95 Ms
At Dc 20 ... 95 Ms
Opening Delay
At Ac 40 ... 60 Ms
At Dc 40 ... 60 Ms
Arcing Time 10 ... 15 Ms
Control Version Of The Switch Operating Mechanism Standard A1 - A2

Auxiliary Circuit

Number Of Nc Contacts For Auxiliary Contacts Instantaneous
Contact2
Number Of No Contacts For Auxiliary Contacts Instantaneous
Contact2
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 6 A
At 400 V Rated Value 3 A
At 500 V Rated Value 2 A
At 690 V Rated Value 1 A
Operation Al Current At Dc-12
At 24 V Rated Value 10 A
At 48 V Rated Value 6 A
At 60 V Rated Value 6 A
At 110 V Rated Value 3 A
At 125 V Rated Value 2 A
At 220 V Rated Value 1 A
At 600 V Rated Value 0.15 A
Operation Al Current At Dc-13
At 24 V Rated Value 10 A
At 48 V Rated Value 2 A
At 60 V Rated Value 2 A
At 110 V Rated Value 1 A
At 125 V Rated Value 0.9 A
At 220 V Rated Value 0.3 A
At 600 V Rated Value 0.1 A
Contact Reliability Of Auxiliary Contacts 1 Faulty Switching Per 100 Million (17 V, 1 Ma)
Ul/Csa Ratings
Full-Load Current (Fla) For 3-Phase Ac Motor
At 480 V Rated Value 180 A
At 600 V Rated Value 192 A
Yielded Mechanical Performance [Hp]
For 3-Phase Ac Motor
— At 200/208 V Rated Value 40 Hp
— At 220/230 V Rated Value 50 Hp
— At 460/480 V Rated Value 100 Hp
— At 575/600 V Rated Value 100 Hp
Contact Rating Of Auxiliary Contacts According To Ul A600 / Q600
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required Gg: 355 A (690 V, 100 Ka)
— With Type Of Assignment 2 Required Gg: 315 A (690 V, 100 Ka), Am: 200 A (690 V, 50 Ka), Bs88: 315 A (415 V, 50
Ka)
For Short-Circuit Protection Of The Auxiliary Switch Required Gg: 10 A (500 V, 1 Ka)
Installation/ Mounting/ Dimensions
Mounting Position With Vertical Mounting Surface +/-90° Rotatable, With Vertical Mounting Surface
+/- 22.5° Tiltable To The Front And Back
Fastening Method Side-By-Side Mounting Yes
Fastening Method Screw Fixing
Height 172 Mm
Width 120 Mm
Depth 170 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 20 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 0 Mm
For Grounded Parts
— Forwards 20 Mm
— Upwards 10 Mm
— At The Side 10 Mm
— Downwards 10 Mm
For Live Parts
— Forwards 20 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Connection Bar
For Auxiliary And Control Circuit Screw-Type Terminals
At Contactor For Auxiliary Contacts Screw-Type Terminals
Of Magnet Coil Screw-Type Terminals
Width Of Connection Bar 17 Mm
Thickness Of Connection Bar 3 Mm
Diameter Of Holes 9 Mm
Number Of Holes 1
Type Of Connectable Conductor Cross-Sections
For Awg Cables For Main Contacts 4 ... 250 Kcmil
Connectable Conductor Cross-Section For Main Contacts
Stranded 25 ... 120 Mm²
Connectable Conductor Cross-Section For Auxiliary Contacts
Solid Or Stranded 0.5 ... 4 Mm²
Finely Stranded With Core End Processing 0.5 ... 2.5 Mm²
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 2.5 Mm²), Max. 2X (0.75 ... 4 Mm²)
— Solid Or Stranded 2X (0,5 ... 1,5 Mm²), 2X (0,75 ... 2,5 Mm²), Max. 2X (0,75 ... 4 Mm²)
— Finely Stranded With Core End Processing 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (20 ... 16), 2X (18 ... 14), 1X 12
Awg Number As Coded Connectable Conductor Cross
Section
For Auxiliary Contacts 18 ... 14

Product Function

Mirror Contact According To Iec 60947-4-1 Yes
Positively Driven Operation According To Iec 60947-5-1 No
Suitable For Safety Function Yes
Suitability For Use Safety-Related Switching Off Yes
Service Life Maximum 20 A
Test Wear-Related Service Life Necessary Yes
Proportion Of Dangerous Failures
With Low Demand Rate According To Sn 31920 40 %
With High Demand Rate According To Sn 31920 73 %
B10 Value With High Demand Rate According To Sn 31920 1 000 000
Failure Rate [Fit] With Low Demand Rate According To Sn
31920100 Fit
Iso 13849
Device Type According To Iso 13849-1 3
Overdimensioning According To Iso 13849-2 Necessary Yes
Iec 61508
Safety Device Type According To Iec 61508-2 Type A
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip00; Ip20 With Box Terminal/Cover
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front With Box Terminal/Cover