3RT19262GJ51

3RT19262GJ51 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RT19262GJ51 Siemens

3RT19262GJ51 Siemens - Solid-state time-delayed auxiliary switch, can be snapped on at the front, time range 1.5...30s, 24 V AC/DC, 2 NO, star-delta (wye-delta) function, sizes S6...S12

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RT1926-2GJ51
Product Description Solid-state time-delayed auxiliary switch, can be snapped on at the front, time range 1.5...30s, 24 V AC/DC, 2 NO, star-delta (wye-delta) function, sizes S6...S12
Product family Ordering Data Overview
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2024
Notes The product was replaced with the following successor product: 3RP2574-1NW30 Compare Products

Successor information

Successor 3RP2574-1NW30
Successor Description Timing relay, electronic with star-delta (wye-delta) function 1 NO delayed 1 NO instantaneous 1 time range, 1...20 s 12-240 V AC/DC at 50/60 Hz AC screw terminal

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,091 Kg
Packaging Dimension 50,00 x 105,00 x 45,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209315907
UPC Not available
Commodity Code 85364190
LKZ_FDB/ CatalogID CC-IC10
Product Group 5347
Group Code R711
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Contactor Can Be Combined Company-Specific S6 ... S12
Product Component Semi-Conductor Output No
Product Extension Required Remote Control No
Product Extension Optional Remote Control No
Insulation Voltage For Overvoltage Category Iii According To Iec
60664 With Degree Of Pollution 3 Rated Value300 V
Degree Of Pollution 3
Surge Voltage Resistance Rated Value 4 000 V
Shock Resistance According To Iec 60068-2-27 11G / 15 Ms
Vibration Resistance According To Iec 60068-2-6 10 ... 55 Hz: 0.35 Mm
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Electrical Endurance (Operating Cycles) At Ac-15 At 230 V
Typical100 000
Adjustable Time 1.5 ... 30 S
Relative Setting Accuracy Relating To Full-Scale Value 15 %
Recovery Time 150 Ms
Reference Code According To Iec 81346-2 K
Active Principle Electronic
Relative Repeat Accuracy 1 %
Substance Prohibitance (Date) 07/01/2006
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.091 Kg

Product Function

Product Function Star-Delta Circuit Yes
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Ac/Dc
Control Supply Voltage 1 At Ac
At 50 Hz Rated Value 24 V
At 60 Hz Rated Value 24 V
Control Supply Voltage Frequency 1 50 ... 60 Hz
Control Supply Voltage 1 At Dc Rated Value 24 V
Operating Range Factor Control Supply Voltage Rated Value At
Dc
Initial Value 0.85
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 50 Hz
Initial Value 0.85
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 60 Hz
Initial Value 0.85
Full-Scale Value 1.1
Switching Function
Switching Function
On-Delay No
On-Delay/Instantaneous Contact No
Passing Make Contact No
Passing Make Contact/Instantaneous Contact No
Off Delay No
Switching Function
Flashing Symmetrically With Interval Start/Instantaneous No
Flashing Symmetrically With Interval Start No
Flashing Symmetrically With Pulse Start/Instantaneous No
Flashing Symmetrically With Pulse Start No
Flashing Asymmetrically With Interval Start No
Flashing Asymmetrically With Pulse Start No
Switching Function
Constant Clock Cycle With Pulse Start No
Constant Clock Cycle With Interval Start No
Switching Function
Variably Clocked With Pulse Start No
Variably Clocked With Interval Start No
Switching Function
Star-Delta Circuit With Delay Time No
Star-Delta Circuit Yes
Switching Function With Control Signal
Additive On-Delay No
Passing Break Contact No
Passing Break Contact/Instantaneous No
Off Delay No
Off Delay/Instantaneous No
Pulse Delayed No
Pulse Delayed/Instantaneous No
Pulse-Shaping No
Pulse-Shaping/Instantaneous No
Additive On-Delay/Instantaneous No
On-Delay/Off-Delay No
On-Delay/Off-Delay/Instantaneous No
Passing Make Contact No
Passing Make Contact/Instantaneous Contact No
Switching Function Of Interval Relay With Control Signal
Retrotriggerable With Deactivated Control
Signal/Instantaneous Contactno
Retrotriggerable With Switched-On Control Signal No
Retrotriggerable With Switched-On Control
Signal/Instantaneous Contactno
Retriggerable With Deactivated Control Signal No
Design Of The Control Terminal Non-Floating No
Short-Circuit Protection
Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary
Switch Requiredfuse Gl/Gg: 4 A

Auxiliary Circuit

Number Of Nc Contacts
Delayed Switching 0
Instantaneous Contact 0
Number Of No Contacts
Delayed Switching 1
Instantaneous Contact 1
Number Of Co Contacts
Delayed Switching 0
Instantaneous Contact 0
Operation Al Current Of Auxiliary Contacts At Ac-15
Maximum 3 A
Operation Al Current Of Auxiliary Contacts As Nc Contact At
Ac-15
At 24 V 3 A
At 250 V 3 A
Operation Al Current Of Auxiliary Contacts As No Contact At
Ac-15
At 24 V 3 A
At 250 V 3 A
Operation Al Current Of Auxiliary Contacts At Dc-13
At 24 V 1 A
At 125 V 0.2 A
At 250 V 0.1 A

Inputs/ Outputs

Product Function
At The Relay Outputs Switchover Delayed/Without Delay No
Non-Volatile No

Electromagnetic Compatibility

Emc Immunity According To Iec 61812-1 En 61000-6-2

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv Network Connection / 1 Kv Control Connection
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 4 Kv Contact Discharge / 8 Kv Air Discharge

Safety Related Data

Category According To En 954-1 None
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front
Type Of Insulation Basic Insulation

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuitno
Type Of Electrical Connection For Auxiliary And Control Circuit Screw-Type Terminals
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 4.0 Mm²), 2X (0.5 ... 2.5 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 2.5 Mm²), 2X (0.5 ... 1.5 Mm²)
For Awg Cables Solid 2X (20 ... 14)
For Awg Cables Stranded 2X (20 ... 14)
Connectable Conductor Cross-Section
Solid 0.5 ... 4 M²
Finely Stranded With Core End Processing 0.5 ... 2.5 M²
Awg Number As Coded Connectable Conductor Cross
Section
Solid 18 ... 14
Stranded 18 ... 14
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Clip-On
Height 46 Mm
Width 33 Mm
Depth 73 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 0 M
— Backwards 0 M
— Upwards 0 M
— Downwards 0 M
— At The Side 0 M
For Grounded Parts
— Forwards 0 M
— Backwards 0 M
— Upwards 0 M
— At The Side 0 M
— Downwards 0 M
For Live Parts
— Forwards 0 M
— Backwards 0 M
— Upwards 0 M
— Downwards 0 M
— At The Side 0 M

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +85 °C
During Transport -40 ... +85 °C
Relative Humidity During Operation 15 ... 95 %