This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3RU2136-4RD0

3RU2136-4RD0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RU2136-4RD0 Siemens

3RU2136-4RD0 Siemens - OVERLOAD S2 CL10 70-80A SPRING AUX

Extended Description for 3RU2136-4RD0 Siemens

3RU2136-4RD0 Siemens - OVERLOAD RELAY 70...80 A FOR MOTOR PROTECTION SIZE S2, CLASS 10 FOR MOUNTING ONTO CONTACTORS MAIN CIRCUIT: SCREW TERMINAL AUX. CIRCUIT: SPRING-T. TERM. MANUAL-AUTOMATIC-RESET.

Free Delivery to UK Mainland on orders over £25

Manufacturer New

4 available
1 - 2 w.days
£112.44 Exc. VAT
£134.93 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£84.99 Exc. VAT
£101.99 Inc. VAT

Product

Article Number (Market Facing Number) 3RU2136-4RD0
Product Description Overload relay 70...80 A Thermal For motor protection Size S2, Class 10A Contactor mounting Main circuit: Screw Auxiliary circuit: spring-type terminal Manual-Automatic-Reset
Product family SIRIUS 3RU2 thermal overload relays
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,340 Kg
Packaging Dimension 61,00 x 96,00 x 111,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209916999
UPC 887621919825
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5346
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 15.10.2014
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of Overload Relay S2
Size Of Contactor Can Be Combined Company-Specific S2
Power Loss [W] For Rated Value Of The Current At Ac In Hot
Operating State18.9 W
Per Pole 6.3 W
Insulation Voltage With Degree Of Pollution 3 At Ac Rated Value 690 V
Surge Voltage Resistance Rated Value 6 Kv
Maximum Permissible Voltage For Protective Separation
In Networks With Ungrounded Star Point Between Auxiliary
And Auxiliary Circuit415 V
In Networks With Grounded Star Point Between Auxiliary
And Auxiliary Circuit415 V
In Networks With Ungrounded Star Point Between Main And
Auxiliary Circuit690 V
In Networks With Grounded Star Point Between Main And
Auxiliary Circuit690 V
Shock Resistance According To Iec 60068-2-27 8G / 11 Ms
Recovery Time After Overload Trip
With Automatic Reset Typical 10 Min
With Remote-Reset 10 Min
With Manual Reset 10 Min
Reference Code According To Iec 81346-2 F
Substance Prohibitance (Date) 10/15/2014
Svhc Substance Name Lead - 7439-92-1
Weight 0.34 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -40 ... +70 °C
During Storage -55 ... +80 °C
During Transport -55 ... +80 °C
Temperature Compensation -40 ... +60 °C
Relative Humidity During Operation 10 ... 95 %
Environmental Footprint
Global Warming Potential [Co2 Eq] Total 108 Kg
Global Warming Potential [Co2 Eq] During Manufacturing 1.76 Kg
Global Warming Potential [Co2 Eq] During Sales 0.082 Kg
Global Warming Potential [Co2 Eq] During Operation 107 Kg
Global Warming Potential [Co2 Eq] After End Of Life -0.086 Kg

Main Circuit

Number Of Poles For Main Current Circuit 3
Adjustable Current Response Value Current Of The Current-
Dependent Overload Release70 ... 80 A
Operating Voltage
Rated Value 690 V
At Ac-3E Rated Value Maximum 690 V
Operating Frequency Rated Value 50 ... 60 Hz
Operation Al Current Rated Value 80 A
Operation Al Current At Ac-3E At 400 V Rated Value 80 A
Operating Power
At Ac-3
— At 400 V Rated Value 37 Kw
— At 500 V Rated Value 55 Kw
— At 690 V Rated Value 75 Kw
At Ac-3E
— At 400 V Rated Value 37 Kw
— At 500 V Rated Value 55 Kw
— At 690 V Rated Value 75 Kw

Auxiliary Circuit

Design Of The Auxiliary Switch Integrated
Number Of Nc Contacts For Auxiliary Contacts 1
Note For Contactor Disconnection
Number Of No Contacts For Auxiliary Contacts 1
Note For Message "Tripped"
Number Of Co Contacts For Auxiliary Contacts 0
Operation Al Current Of Auxiliary Contacts At Ac-15
At 24 V 3 A
At 110 V 3 A
At 120 V 3 A
At 125 V 3 A
At 230 V 2 A
At 400 V 1 A
At 690 V 0.75 A
Operation Al Current Of Auxiliary Contacts At Dc-13
At 24 V 2 A
At 60 V 0.3 A
At 110 V 0.22 A
At 125 V 0.22 A
At 220 V 0.11 A
Design Of The Miniature Circuit Breaker For Short-Circuit Protection
Of The Auxiliary Switch Required6A (Scc Less Than Equal To 0.5 Ka; U Less Than Equal To 260V)
Contact Rating Of Auxiliary Contacts According To Ul B600 / R300
Protective And Monitoring Functions
Trip Class Class 10A
Design Of The Overload Release Thermal
Ul/Csa Ratings
Full-Load Current (Fla) For 3-Phase Ac Motor
At 480 V Rated Value 80 A
At 600 V Rated Value 80 A
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse Gg: 6 A, Quick: 10 A
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Contactor Mounting
Height 90 Mm
Width 55 Mm
Depth 105 Mm

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuitno
Type Of Electrical Connection
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Spring-Loaded Terminals
Arrangement Of Electrical Connectors For Main Current
Circuittop And Bottom
Type Of Connectable Conductor Cross-Sections
For Main Contacts
— Solid Or Stranded 2X (1 ... 35 Mm²), 1X (1 ... 50 Mm²)
— Finely Stranded With Core End Processing 2X (1 ... 25 Mm²), 1X (1 ... 35 Mm²)
For Awg Cables For Main Contacts 2X (18 ... 2), 1X (18 ... 1)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid Or Stranded 2X (0.5 ... 2.5 Mm²)
— Finely Stranded With Core End Processing 2X (0.5 ... 1.5 Mm²)
— Finely Stranded Without Core End Processing 2X (0.5 ... 2.5 Mm²)
For Awg Cables For Auxiliary Contacts 2X (20 ... 14)
Tightening Torque
For Main Contacts With Screw-Type Terminals 3 ... 4.5 N·M
Design Of Screwdriver Shaft Diameter 5 ... 6 Mm
Size Of The Screwdriver Tip Pozidriv Pz 2
Design Of The Thread Of The Connection Screw
For Main Contacts M6
Iec 61508
T1 Value
For Proof Test Interval Or Service Life According To Iec
6150820 A
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front
Display
Display Version For Switching Status Slide Switch

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible