Description for 3RV1611-1AG14 Siemens

3RV1611-1AG14 Siemens - MSP, 1.4A MSP S00 FOR TRANS. W/AUX SW

Extended Description for 3RV1611-1AG14 Siemens

3RV1611-1AG14 Siemens - TRANSFORMER, 1CO, S00, 1.4A CIRCUIT-BREAKER FOR VOLTAGE

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£164.31 Exc. VAT
£197.17 Inc. VAT

Product

Article Number (Market Facing Number) 3RV1611-1AG14
Product Description Voltage transformer Circuit breaker, Size S00 1.4 A, N-release 6 A, 1 CO with transverse auxiliary switch
Product family SIRIUS 3RV1 motor starter protectors
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,301 Kg
Packaging Dimension 49,00 x 100,00 x 84,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209535213
UPC 754554899558
Commodity Code 85362010
LKZ_FDB/ CatalogID CC-IC10
Product Group 3715
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Size Of The Circuit-Breaker S00
Product Extension Auxiliary Switch Yes
Power Loss [W] For Rated Value Of The Current
At Ac In Hot Operating State 7.25 W
At Ac In Hot Operating State Per Pole 2.4 W
Insulation Voltage With Degree Of Pollution 3 At Ac Rated Value 690 V
Surge Voltage Resistance Rated Value 6 Kv
Mechanical Service Life (Operating Cycles)
Of The Main Contacts Typical 10 000
Of Auxiliary Contacts Typical 10 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 01/01/2013
Svhc Substance Name Lead - 7439-92-1
Weight 0.301 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -20 ... +60 °C
During Storage -50 ... +80 °C
During Transport -50 ... +80 °C
Relative Humidity During Operation 10 ... 95 %

Main Circuit

Number Of Poles For Main Current Circuit 3
Operating Voltage
Rated Value 20 ... 690 V
At Ac-3 Rated Value Maximum 400 V
At Ac-3E Rated Value Maximum 400 V
Operating Frequency Rated Value 60 Hz
Operation Al Current Rated Value 1.4 A
Operation Al Current
At Ac-3 At 400 V Rated Value 1.4 A
At Ac-3E At 400 V Rated Value 1.4 A
Operating Frequency
At Ac-3 Maximum 15 1/H
At Ac-3E Maximum 15 1/H

Auxiliary Circuit

Design Of The Auxiliary Switch Transverse
Number Of Nc Contacts For Auxiliary Contacts 1
Note 1
Number Of No Contacts For Auxiliary Contacts 1
Note 1
Number Of Co Contacts For Auxiliary Contacts 1
Operation Al Current Of Auxiliary Contacts At Dc-13
At 24 V 0.3 A
At 60 V 0.3 A
Protective And Monitoring Functions

Product Function

Ground Fault Detection No
Phase Failure Detection Yes
Design Of The Overload Release Thermal
Maximum Short-Circuit Current Breaking Capacity (Icu)
At Ac At 240 V Rated Value 100 Ka
At Ac At 400 V Rated Value 50 Ka
Operating Short-Circuit Current Breaking Capacity (Ics) At Ac
At 240 V Rated Value 100 Ka
At 400 V Rated Value 50 Ka
Response Value Current Of Instantaneous Short-Circuit Trip Unit 6 A
Ul/Csa Ratings
Full-Load Current (Fla) For 3-Phase Ac Motor
At 480 V Rated Value 1.4 A
At 600 V Rated Value 1.4 A
Short-Circuit Protection
Product Function Short Circuit Protection Yes
Design Of The Short-Circuit Trip Magnetic
Design Of The Fuse Link
For Short-Circuit Protection Of The Auxiliary Switch Required 2A Ff 250V/1.1Ka
Design Of The Fuse Link For It Network For Short-Circuit
Protection Of The Main Circuit
At 240 V None Required
At 400 V Gl/Gg 20 A
At 500 V Gl/Gg 20 A
At 690 V Gl/Gg 20 A
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail According To Din En 60715
Height 90 Mm
Width 45 Mm
Depth 75 Mm
Required Spacing
For Grounded Parts At 400 V
— Downwards 20 Mm
— Upwards 20 Mm
— At The Side 9 Mm
For Live Parts At 400 V
— Downwards 20 Mm
— Upwards 20 Mm
— At The Side 9 Mm
For Grounded Parts At 500 V
— Downwards 20 Mm
— Upwards 20 Mm
— At The Side 9 Mm
For Live Parts At 500 V
— Downwards 20 Mm
— Upwards 20 Mm
— At The Side 9 Mm
For Grounded Parts At 690 V
— Downwards 20 Mm
— Upwards 20 Mm
— Backwards 0 Mm
— At The Side 9 Mm
— Forwards 0 Mm
For Live Parts At 690 V
— Downwards 20 Mm
— Upwards 20 Mm
— Backwards 0 Mm
— At The Side 9 Mm
— Forwards 0 Mm

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Screw-Type Terminals
Arrangement Of Electrical Connectors For Main Current
Circuittop And Bottom
Type Of Connectable Conductor Cross-Sections
For Main Contacts
— Solid Or Stranded 2X (0,5 ... 1,5 Mm²), 2X (0,75 ... 2,5 Mm²), 2X (1 ... 4 Mm²)
— Finely Stranded With Core End Processing 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 2.5 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid Or Stranded 2X (0.5 ... 1.5 Mm²), 2X (0.75 ... 2.5 Mm²)
Tightening Torque
For Main Contacts With Screw-Type Terminals 0.8 ... 1.2 N·M
For Auxiliary Contacts With Screw-Type Terminals 0.8 ... 1.2 N·M
Size Of The Screwdriver Tip Pozidriv Size 2
Design Of The Thread Of The Connection Screw
For Main Contacts M3
Of The Auxiliary And Control Contacts M3
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front
Display
Display Version For Switching Status Rocker Switch

Documentation