3RW4443-2BC45 Siemens - SIRIUS soft starter Values at 500 V, 40 °C standard: 203 A, 132 kW Inside-delta: 352 A, 250 kW 400-600 V AC, 230 V AC spring-type terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5543-2HA16<<

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RW4443-2BC45
Product Description SIRIUS soft starter Values at 500 V, 40 °C standard: 203 A, 132 kW Inside-delta: 352 A, 250 kW 400-600 V AC, 230 V AC spring-type terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5543-2HA16<<
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2023
Notes Product is no longer available If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 11,180 Kg
Packaging Dimension 346,00 x 435,00 x 374,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209627352
UPC 754554924656
Commodity Code 85371098
LKZ_FDB/ CatalogID CC-IC10
Product Group 3728
Group Code R711
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 28.05.2009
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead titanium zirconium oxide Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Product Brand Name Sirius
Product Designation Soft Starter
Product Feature
Integrated Bypass Contact System Yes
Thyristors Yes

Product Function

Intrinsic Device Protection Yes
Motor Overload Protection Yes
Evaluation Of Thermistor Motor Protection Yes
External Reset Yes
Adjustable Current Limitation Yes
Inside-Delta Circuit Yes
Product Component Motor Brake Output Yes
Insulation Voltage Rated Value V 690
Degree Of Pollution 3, Acc. To Iec 60947-4-2
Reference Code According To En 61346-2 Q
Reference Code According To Din 40719 Extended According
To Iec 204-2 According To Iec 750G
Power Electronics
Operation Al Current
At 40 °C Rated Value A 203
At 50 °C Rated Value A 180
At 60 °C Rated Value A 156
Operation Al Current For 3-Phase Motors At Inside-Delta
Circuit
At 40 °C Rated Value A 352
At 50 °C Rated Value A 312
At 60 °C Rated Value A 270
Yielded Mechanical Performance For 3-Phase Motors
At 400 V
— At Standard Circuit At 40 °C Rated Value Kw 110
— At Inside-Delta Circuit At 40 °C Rated Value Kw 200
At 500 V
— At Standard Circuit At 40 °C Rated Value Kw 132
— At Inside-Delta Circuit At 40 °C Rated Value Kw 250
Operating Frequency Rated Value Hz 50 ... 60
Relative Negative Tolerance Of The Operating Frequency % -10
Relative Positive Tolerance Of The Operating Frequency % 10
Operating Voltage At Standard Circuit Rated Value V 400 ... 600
Relative Negative Tolerance Of The Operating Voltage At % -15
Standard Circuit
Relative Positive Tolerance Of The Operating Voltage At
Standard Circuit% 10
Operating Voltage At Inside-Delta Circuit Rated Value V 400 ... 600
Relative Negative Tolerance Of The Operating Voltage At
Inside-Delta Circuit% -15
Relative Positive Tolerance Of The Operating Voltage At
Inside-Delta Circuit% 10
Minimum Load [%] % 8
Adjustable Motor Current For Motor Overload Protection
Minimum Rated Valuea 40
Continuous Operating Current [% Of Ie] At 40 °C % 115
Power Loss [W] At Operational Current At 40 °C During
Operation Typicalw 89
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Ac
Control Supply Voltage Frequency 1 Rated Value Hz 50
Control Supply Voltage Frequency 2 Rated Value Hz 60
Relative Negative Tolerance Of The Control Supply Voltage
Frequency% -10
Relative Positive Tolerance Of The Control Supply Voltage
Frequency% 10
Control Supply Voltage 1 At Ac
At 50 Hz Rated Value V 230
At 60 Hz Rated Value V 230
Relative Negative Tolerance Of The Control Supply Voltage At
Ac At 50 Hz% -15
Relative Positive Tolerance Of The Control Supply Voltage At
Ac At 50 Hz% 10
Relative Negative Tolerance Of The Control Supply Voltage At
Ac At 60 Hz% -15
Relative Positive Tolerance Of The Control Supply Voltage At
Ac At 60 Hz% 10
Display Version For Fault Signal Display

Mechanical Data

Width Mm 210
Height Mm 230
Depth Mm 298
Fastening Method Screw Fixing
Mounting Position With Vertical Mounting Surface +/-90° Rotatable, With Vertical
Mounting Surface +/- 22.5° Tiltable To The Front And Back
Required Spacing With Side-By-Side Mounting
Upwards Mm 100
At The Side Mm 5
Downwards Mm 75
Wire Length Maximum M 500
Number Of Poles For Main Current Circuit 3

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Busbar Connection
For Auxiliary And Control Circuit Spring-Loaded Terminals
Number Of Nc Contacts For Auxiliary Contacts 0
Number Of No Contacts For Auxiliary Contacts 3
Number Of Co Contacts For Auxiliary Contacts 1
Type Of Connectable Conductor Cross-Sections For Main
Contacts For Box Terminal Using The Front Clamping Point
Finely Stranded With Core End Processing 70 ... 240 Mm²
Finely Stranded Without Core End Processing 70 ... 240 Mm²
Stranded 95 ... 300 Mm²
Type Of Connectable Conductor Cross-Sections For Main
Contacts For Box Terminal Using The Back Clamping Point
Finely Stranded With Core End Processing 120 ... 185 Mm²
Finely Stranded Without Core End Processing 120 ... 185 Mm²
Stranded 120 ... 240 Mm²
Type Of Connectable Conductor Cross-Sections For Main
Contacts For Box Terminal Using Both Clamping Points
Finely Stranded With Core End Processing Min. 2X 50 Mm², Max. 2X 185 Mm²
Finely Stranded Without Core End Processing Min. 2X 50 Mm², Max. 2X 185 Mm²
Stranded Max. 2X 70 Mm², Max. 2X 240 Mm²
Type Of Connectable Conductor Cross-Sections For Awg
Cables For Main Contacts For Box Terminal
Using The Back Clamping Point 250 ... 500 Kcmil
Using The Front Clamping Point 3/0 ... 600 Kcmil
Using Both Clamping Points Min. 2X 2/0, Max. 2X 500 Kcmil
Type Of Connectable Conductor Cross-Sections For Din Cable
Lug For Main Contacts
Finely Stranded 50 ... 240 Mm²
Stranded 70 ... 240 Mm²
Type Of Connectable Conductor Cross-Sections For Auxiliary
Contacts
Solid 2X (0.25 ... 1.5 Mm²)
Finely Stranded With Core End Processing 2X (0.25 ... 1.5 Mm²)
Type Of Connectable Conductor Cross-Sections For Awg
Cables
For Main Contacts 2/0 ... 500 Kcmil
For Auxiliary Contacts 2X (24 ... 16)

Ambient Conditions

Installation Altitude At Height Above Sea Level M 5 000
Environmental Category
During Transport According To Iec 60721 2K2, 2C1, 2S1, 2M2 (Max. Fall Height 0.3 M)
During Storage According To Iec 60721 1K6 (Only Occasional Condensation), 1C2 (No Salt Mist), 1S2
(Sand Must Not Get Inside The Devices), 1M4
During Operation According To Iec 60721 3K6 (No Formation Of Ice, No Condensation), 3C3 (No Salt Mist),
3S2 (Sand Must Not Get Into The Devices), 3M6
Ambient Temperature
During Operation °C 60
During Storage °C -25 ... +80
Derating Temperature °C 40
Protection Class Ip On The Front According To Iec 60529 Ip00; Ip20 With Box Terminal/Cover
Touch Protection On The Front According To Iec 60529 Finger-Safe, For Vertical Contact From The Front With Box
Terminal/Cover
Ul/Csa Ratings
Yielded Mechanical Performance [Hp] For 3-Phase Ac Motor
At 460/480 V
— At Standard Circuit At 50 °C Rated Value Hp 125
— At Inside-Delta Circuit At 50 °C Rated Value Hp 250
At 575/600 V
— At Standard Circuit At 50 °C Rated Value Hp 150
— At Inside-Delta Circuit At 50 °C Rated Value Hp 300
Contact Rating Of Auxiliary Contacts According To Ul B300 / R300