This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3RW4466-6BC34

3RW4466-6BC34 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3RW4466-6BC34 Siemens

3RW4466-6BC34 Siemens - SIRIUS soft starter Values at 460 V, 50 °C standard: 1076 A, 950 hp Inside-delta: 1864 A, 1700 hp 200-460 V AC, 115 V AC Screw terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5558-6HA14<<

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3RW4466-6BC34
Product Description SIRIUS soft starter Values at 460 V, 50 °C standard: 1076 A, 950 hp Inside-delta: 1864 A, 1700 hp 200-460 V AC, 115 V AC Screw terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5558-6HA14<<
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2023
Notes Product is no longer available If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 97,000 Kg
Packaging Dimension 830,00 x 640,00 x 490,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209681132
UPC 754554945842
Commodity Code 85371098
LKZ_FDB/ CatalogID CC-IC10
Product Group 3728
Group Code R711
Country of origin Czech Republic
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead titanium zirconium oxide Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Product Brand Name Sirius
Product Designation Soft Starter
Product Feature
Integrated Bypass Contact System Yes
Thyristors Yes

Product Function

Intrinsic Device Protection Yes
Motor Overload Protection Yes
Evaluation Of Thermistor Motor Protection Yes
External Reset Yes
Adjustable Current Limitation Yes
Inside-Delta Circuit Yes
Product Component Motor Brake Output Yes
Insulation Voltage Rated Value V 690
Degree Of Pollution 3, Acc. To Iec 60947-4-2
Reference Code According To En 61346-2 Q
Reference Code According To Din 40719 Extended According
To Iec 204-2 According To Iec 750G
Power Electronics
Operation Al Current
At 40 °C Rated Value A 1 214
At 50 °C Rated Value A 1 076
At 60 °C Rated Value A 970
Operation Al Current For 3-Phase Motors At Inside-Delta
Circuit
At 40 °C Rated Value A 2 103
At 50 °C Rated Value A 1 864
At 60 °C Rated Value A 1 680
Yielded Mechanical Performance For 3-Phase Motors
At 230 V
— At Standard Circuit At 40 °C Rated Value Kw 400
— At Inside-Delta Circuit At 40 °C Rated Value Kw 710
At 400 V
— At Standard Circuit At 40 °C Rated Value Kw 710
— At Inside-Delta Circuit At 40 °C Rated Value Kw 1 200
Yielded Mechanical Performance [Hp] For 3-Phase Ac Motor
At 200/208 V At Standard Circuit At 50 °C Rated Valuehp 400
Operating Frequency Rated Value Hz 50 ... 60
Relative Negative Tolerance Of The Operating Frequency % -10
Relative Positive Tolerance Of The Operating Frequency % 10
Operating Voltage At Standard Circuit Rated Value V 200 ... 460
Relative Negative Tolerance Of The Operating Voltage At
Standard Circuit% -15
Relative Positive Tolerance Of The Operating Voltage At
Standard Circuit% 10
Operating Voltage At Inside-Delta Circuit Rated Value V 200 ... 460
Relative Negative Tolerance Of The Operating Voltage At
Inside-Delta Circuit% -15
Relative Positive Tolerance Of The Operating Voltage At
Inside-Delta Circuit% 10
Minimum Load [%] % 8
Adjustable Motor Current For Motor Overload Protection
Minimum Rated Valuea 242
Continuous Operating Current [% Of Ie] At 40 °C % 115
Power Loss [W] At Operational Current At 40 °C During
Operation Typicalw 630
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Ac
Control Supply Voltage Frequency 1 Rated Value Hz 50
Control Supply Voltage Frequency 2 Rated Value Hz 60
Relative Negative Tolerance Of The Control Supply Voltage
Frequency% -10
Relative Positive Tolerance Of The Control Supply Voltage
Frequency% 10
Control Supply Voltage 1 At Ac
At 50 Hz Rated Value V 115
At 60 Hz Rated Value V 115
Relative Negative Tolerance Of The Control Supply Voltage At
Ac At 50 Hz% -15
Relative Positive Tolerance Of The Control Supply Voltage At
Ac At 50 Hz% 10
Relative Negative Tolerance Of The Control Supply Voltage At
Ac At 60 Hz% -15
Relative Positive Tolerance Of The Control Supply Voltage At
Ac At 60 Hz% 10
Display Version For Fault Signal Display

Mechanical Data

Width Mm 575
Height Mm 780
Depth Mm 292
Fastening Method Screw Fixing
Mounting Position With Vertical Mounting Surface +/-90° Rotatable, With Vertical
Mounting Surface +/- 22.5° Tiltable To The Front And Back
Required Spacing With Side-By-Side Mounting
Upwards Mm 100
At The Side Mm 5
Downwards Mm 75
Wire Length Maximum M 500
Number Of Poles For Main Current Circuit 3

Connections/ Terminals

Type Of Electrical Connection
For Main Current Circuit Busbar Connection
For Auxiliary And Control Circuit Screw-Type Terminals
Number Of Nc Contacts For Auxiliary Contacts 0
Number Of No Contacts For Auxiliary Contacts 3
Number Of Co Contacts For Auxiliary Contacts 1
Type Of Connectable Conductor Cross-Sections For Din Cable
Lug For Main Contacts
Finely Stranded 50 ... 240 Mm²
Stranded 70 ... 240 Mm²
Type Of Connectable Conductor Cross-Sections For Auxiliary
Contacts
Solid 2X (0.5 ... 2.5 Mm²)
Finely Stranded With Core End Processing 2X (0.5 ... 1.5 Mm²)
Type Of Connectable Conductor Cross-Sections For Awg
Cables
For Main Contacts 2/0 ... 500 Kcmil
For Auxiliary Contacts 2X (20 ... 14)
For Auxiliary Contacts Finely Stranded With Core End
Processing2X (20 ... 16)

Ambient Conditions

Installation Altitude At Height Above Sea Level M 5 000
Environmental Category
During Transport According To Iec 60721 2K2, 2C1, 2S1, 2M2 (Max. Fall Height 0.3 M)
During Storage According To Iec 60721 1K6 (Only Occasional Condensation), 1C2 (No Salt Mist), 1S2
(Sand Must Not Get Inside The Devices), 1M4
During Operation According To Iec 60721 3K6 (No Formation Of Ice, No Condensation), 3C3 (No Salt Mist),
3S2 (Sand Must Not Get Into The Devices), 3M6
Ambient Temperature
During Operation °C 60
During Storage °C -25 ... +80
Derating Temperature °C 40
Protection Class Ip On The Front According To Iec 60529 Ip00
Ul/Csa Ratings
Yielded Mechanical Performance [Hp] For 3-Phase Ac Motor
At 200/208 V
— At Inside-Delta Circuit At 50 °C Rated Value Hp 700
At 220/230 V
— At Standard Circuit At 50 °C Rated Value Hp 450
— At Inside-Delta Circuit At 50 °C Rated Value Hp 850
At 460/480 V
— At Standard Circuit At 50 °C Rated Value Hp 950
— At Inside-Delta Circuit At 50 °C Rated Value Hp 1 700
Contact Rating Of Auxiliary Contacts According To Ul B300 / R300

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible