Description for 3RX9502-0BA00 Siemens

3RX9502-0BA00 Siemens - ASI PS, 115/230VAC SUPPLY, 5A

Extended Description for 3RX9502-0BA00 Siemens

3RX9502-0BA00 Siemens - As-interface power supply IP20 out as-i DC30V, 5a in AC 115v/230v with data decoupling

Free Delivery to UK Mainland on orders over £25

Manufacturer New

2 available
1 - 2 w.days
£412.44 Exc. VAT
£494.93 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£339.86 Exc. VAT
£407.83 Inc. VAT

Product

Article Number (Market Facing Number) 3RX9502-0BA00
Product Description AS-i Power 5A 120 V/230 V AC AS-Interface power supply unit, IP20 IN: 120 V / 230 V AC OUT: AS-i, 5 A (30 V DC), IP20 with integrated ground fault detection, with integrated overload detection with AS-i data decoupling
Product family AS-Interface power supply units
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,715 Kg
Packaging Dimension 137,00 x 143,00 x 85,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209641464
UPC 754554921525
Commodity Code 85044083
LKZ_FDB/ CatalogID CC-IC10
Product Group 3721
Group Code R711
Country of origin Romania
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

General Technical Data

Type Of Device As-Interface Power Supply Unit Ip20
Version Single Output
Additional Function Integrated Ground-Fault Detection, Remote Reset And Remote
Indication
Input Voltage Nominal Value Ac
Range 1 V 120
Range 2 V 230
Inputs
Input Recommended Circuit Breaker (Iec 898) In The Main
Supply Line6 A, Characteristic C
Input Voltage Range
Voltage Range 1 Ac V 85 ... 132
Voltage Range 2 Ac V 176 ... 253
Input
Mains Buffering Time At Ia Rated Min 20 Ms
Line Frequency 50/60 Hz
Mains Frequency Range Hz 47 ... 63
Range Changeover Using Changeover Switch On Device
Input Voltage Built-In T 3.15 (Not Accessible)
Connections Input Spring-Loaded Terminal Connection Input (0.2 ... 2.5 Mm2)/
Diagnosis (0.14 ... 1.5 Mm2)
Outputs
Output
Dc-Voltage Controlled Floating According To As-Interface
Spezificationyes
Voltage Rated Value Ua Rated Dc 30 V
Tolerance Total Dc V 29.5 ... 31.6
Rated Current Ia Rated 5 A
Residual Ripple Peak-To-Peak ( 0-10 Khz, As-I+/As-I- ) Max Mv 300
Spikes Peak-To-Peak ( 10-500 Khz, As-I+/As-I- ) Max Mv 50
Connections Output Spring-Loaded Terminal Connection Output (0.2 ... 2.5 Mm²)/
Diagnosis (0.14 ... 1.5 Mm²)
Efficiency/ Heat Loss
Efficiency At Ua Rated, Ia Rated % 87
Power Loss [W] Maximum W 25.2
Protective And Monitoring Functions
Output Overvoltage Protection Yes (< 35V)
Current Limitation From Min. 5.5 A
Short-Circuit Protection Yes

Safety Related Data

Protection Class ( En 60 950/Iec 950 ) I
Electrical Isolation Primary/Secondary Es1 According En 62368-1 (For Products Until End Of 2020:
Selv According To En 60 950 And En 50 178)
Protection Class Ip Ip20

Electromagnetic Compatibility

Electromagnetic Compatibility (Emc)
Interference Immunity En 61 000-6-2, En 61 000-4-2/-3/-4/-5/-11
Emitted Interference Class B According To En 55 022, Iec 61 000-6-3

Ambient Conditions

Ambient Temperature
During Operation °C -10 ... +70
During Storage °C -25 ... +80
Humidity Rating Climatic Class Din 50010, Relative Humidity Max. 100% Without
Condensation
Fastening Method Fixing On Standard Mounting Rail Din En 59 022-35 X 7.5 Mm
Snap-On
Width Mm 70
Height Mm 125
Depth Mm 125
Environmental Footprint
Global Warming Potential [Co2 Eq] Total Kg 785
Global Warming Potential [Co2 Eq] During Manufacturing Kg 20.7
Global Warming Potential [Co2 Eq] During Sales Kg 0.127
Global Warming Potential [Co2 Eq] During Operation Kg 763
Global Warming Potential [Co2 Eq] After End Of Life Kg 0.565
Certificates/ Approvals
General Product Approval
Confirmation
Emv Marine / Shipping Other
Kc
Confirmation Miscellaneous
Environment Industrial Communication
Environmental Con-
Firmations

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible