This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3SE6415-1BB01

3SE6415-1BB01 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3SE6415-1BB01 Siemens

3SE6415-1BB01 Siemens - RFID safety switch with tumbler, plastic, quiescent current principle, tumbler monitoring, 24 V DC, with auxiliary release, IP69, locking force 1150 N, family-encoded, diagnostics output, M12 plug 8-pole, 3 LEDs for display of the operating states, 3 directions of actuation, latching force with turnstile adjustable: 25 N or 50 N, hygienic design, actuator 3SE6410-1AC01 to be ordered separately

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£548.95 Exc. VAT
£658.74 Inc. VAT

Product

Article Number (Market Facing Number) 3SE6415-1BB01
Product Description RFID safety switch with tumbler, plastic, quiescent current principle, tumbler monitoring, 24 V DC, with auxiliary release, IP69, locking force 1150 N, family-encoded, diagnostics output, M12 plug 8-pole, 3 LEDs for display of the operating states, 3 directions of actuation, latching force with turnstile adjustable: 25 N or 50 N, hygienic design, actuator 3SE6410-1AC01 to be ordered separately
Product family 3SE64 RFID safety switches with tumbler
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,600 Kg
Packaging Dimension 95,00 x 150,00 x 50,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047621095394
UPC Not available
Commodity Code 85365080
LKZ_FDB/ CatalogID CC-IC10
Product Group 3750
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Product Function

Product Function
Positive Opening No
Control Function For Downstream Devices No
Cross-Circuit/Short-Circuit Recognition Yes
Suitability For Use
Safety-Related Circuits Yes

General Technical Data

Product Feature Family-Coded, Catch 25N/50N
Product Feature Suitable For Series Connection Yes
Locking Force 1 500 N
According To En Iso 14119 1 150 N
Design Of The Rfid Coding Universal Coding
Insulation Voltage Rated Value 32 V
Degree Of Pollution According To En 60664-1 3
Overvoltage Category Class Iii
Surge Voltage Resistance Rated Value 0.8 Kv
No-Load Current Rated Value 100 Ma
Shock Resistance
According To Iec 60068-2-27 30G / 11 Ms
Vibration Resistance According To Iec 60068-2-6 10 ... 150 Hz, Amplitude 0.35 Mm
Switching Frequency 0.5 Hz
Mechanical Service Life (Operating Cycles) Typical 1 000 000
Note When Used As Door Stop: ≥ 50,000 Switching Cycles (Door Masses ≤ 5 Kg And
Actuating Speed ≤ 0.5 M/S)
Relative On Period [%] Of Magnet Coil 100 %
Reference Code According To Iec 81346-2 B
Substance Prohibitance (Date) 07/01/2006
Weight 0.6 Kg
Sensor
Height Of The Sensor 35 Mm
Length Of The Sensor 120 Mm
Width Of The Sensor 87.5 Mm

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation 0 ... 60 °C
During Storage And Transport -10 ... +90 °C
Operating Resource Protection Class According To Iec 61140 Iii
Relative Humidity During Operation Maximum 93 %
Note Non-Condensing, Non-Icing
Control Circuit/
Current Consumption Of Magnet Coil Rated Value 100 Ma
Locked-Rotor Current Peak Of Magnet Coil 250 Ma
Duration Of Locked-Rotor Current Peak 200 Ms

Main Circuit

Operating Voltage Rated Value 24 V
Operation Al Current Rated Value 250 Ma
Enclosure
Design Of The Housing Special Design
Material Of The Enclosure Plastic, Fiberglass Reinforced Thermoplast, Self-Extinguishing
Actuator
Product Equipment Auxiliary Release Of Guard Locking Yes
Product Feature Latching Yes
Locking Mechanism Design Quiescent Current Principle
Detent Force Adjustable 1 25 N
Detent Force Adjustable 2 50 N
Angular Offset Between Guard Locking And Actuator
Maximum
Display
Product Function Status Display Yes
Display Version As Status Display By Led 3 Leds
Contact
Circuit Principle Spring-Actuated Lock (Closed-Circuit Principle)
Operating Distance 2 Mm
Assured Operating Distance Off 20 Mm
Assured Operating Distance On 1 Mm
Installation/ Mounting/ Dimensions
Fastening Method Screw Fixing
Design Of The Thread Of The Screw For Securing The
Equipment2X M6
Tightening Torque Of Fixing Screw Minimum 6 N·M
Tightening Torque Of Fixing Screw Maximum 7 N·M

Connections/ Terminals

Type Of Electrical Connection M12 Plug, 8-Pole, A-Coded
Wire Length Maximum 200 M
Contact Assignment
Of Socket 1 At Pin 1 A1 Supply Voltage Ub
Of Socket 1 At Pin 2 X1 Safety Input 1
Of Socket 1 At Pin 3 A2 Gnd
Of Socket 1 At Pin 4 Ossd1 Safety Output 1
Of Socket 1 At Pin 5 Out Diagnostic Output
Of The Bushing 1 At Pin 6 X2 Safety Input 2
Of The Bushing 1 At Pin 7 Ossd2 Safety Output 2
Of The Bushing 1 At Pin 8 In Magnet Controller

Supply Voltage

Type Of Voltage Of The Supply Voltage Dc
Supply Voltage Rated Value 24 V
Supply Voltage 26.4 ... 20.4 V
Fuse Protection Type For External Auxiliary Power Supply
Required2 A Gg

Inputs/ Outputs

Input Voltage At Digital Input
With Signal <0> At Dc -3 ... +5 V
For Signal <1> At Dc 15 ... 30
Input Voltage At Safety-Related Digital Input
For Signal <0> At Dc -3 ... +5 V
For Signal <1> At Dc 15 ... 30 V
Input Current At Digital Input For Signal <1> Typical 10 Ma
Input Current At Safety-Related Digital Input For Signal <1>
Typical5 Ma
Number Of Semiconductor Outputs
For Signaling Function 1
Safety-Related 2
Design Of The Contactless Switching Element Safety-Related Short-Circuit Proof, Sourcing Output
Type Of Diagnostic Output Short-Circuit Proof, Sourcing Output
Dark Period At Safety-Related Digital Output Maximum 0.5 Ms
Dark Period Test Duration
At Digital Input Maximum 5 Ms
At Safety-Related Digital Input Maximum 1 Ms
Dark Period Test Interval
At Digital Input Minimum 40 Ms
At Safety-Related Digital Input Minimum 100 Ms
At Safety-Related Digital Output Maximum 1 000 Ms
Residual Current At Digital Output With Signal <0> Maximum 0.5 Ma
Voltage Drop
At Safety-Related Output Maximum 2 V
At Diagnostic Output Maximum 2 V
Output Current Minimum 0.5 Ma
Output Current At Safety-Related Output Maximum 0.25 A
Output Current At Diagnostic Output Maximum 0.05 A

Communication/ Protocol

Design Of The Interface For Safety-Related Communication Connector M12
Transmission Frequency Rated Value 125 Khz

Safety Related Data

Product Function Suitable For Safety Function Yes
Category According To En 954-1 4
Iec 62061
Safety Integrity Level (Sil)
For Position Monitoring According To Iec 62061 3
For Guard Locking According To Iec 62061 2
Pfhd With High Demand Rate
For Position Monitoring According To Iec 62061 5.2E-9 1/H
For Guard Locking According To Iec 62061 2E-9 1/H
Iso 13849
Performance Level (Pl) According To En Iso 13849-1 Pl E
Category According To En Iso 13849-1 4
Performance Level (Pl)
For Position Monitoring According To Iso 13849-1 E
For Guard Locking According To Iso 13849-1 D
Category
For Position Monitoring According To Iso 13849-1 4
For Guard Locking According To Iso 13849-1 2
Iec 61508
Safety Integrity Level (Sil) According To Iec 61508 3
Pfdavg With Low Demand Rate
For Position Monitoring According To Iec 62061 4.5E-4
For Guard Locking According To Iec 62061 0.0018
T1 Value For Proof Test Interval Or Service Life
For Position Monitoring According To Iec 61508 20 A
For Guard Locking According To Iec 61508 20 A
Type Of Monitoring Guard Locking
Response Delay Maximum 5 000 Ms
Off-Delay Time With Safety-Related Request
When Switched Off Via Control Inputs Maximum 1.5 Ms
For Safety-Related Shutdown Via Actuator Maximum 100 Ms
Conditional Short-Circuit Current (Iq) At 400 V According To Iec
60947-4-1 Rated Value100 A

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible