This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3TC4417-0LJ8

3TC4417-0LJ8 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3TC4417-0LJ8 Siemens

3TC4417-0LJ8 Siemens - Contactor, Size 2, 2-pole, for railway applications DC-3 and 5, 7.5 A at 750 V 72 V DC Auxiliary contacts 21 (2NO+1NC) with varistor and series resistor Operating range 0.7...1.25xUS

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3TC4417-0LJ8
Product Description Contactor, Size 2, 2-pole, for railway applications DC-3 and 5, 7.5 A at 750 V 72 V DC Auxiliary contacts 21 (2NO+1NC) with varistor and series resistor Operating range 0.7...1.25xUS
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99
Estimated dispatch time (Working Days) On request
Net Weight (kg) 1,338 Kg
Packaging Dimension 140,00 x 204,00 x 110,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN Not available
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5807
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.02.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

General Technical Data

Size Of Contactor 2

Product Extension

Function Module For Communication No
Auxiliary Switch No
Insulation Voltage Rated Value 800 V
Maximum Permissible Voltage For Protective Separation Between
Coil And Main Contacts According To En 60947-1300 V
Shock Resistance At Rectangular Impulse
At Dc 7,5G / 5 Ms, 3,4G / 10 Ms
Mechanical Service Life (Operating Cycles)
Of Contactor Typical 10 000 000
Of The Contactor With Added Auxiliary Switch Block Typical 10 000 000
Reference Code According To Iec 81346-2 Q
Substance Prohibitance (Date) 02/01/2012
Weight 1.338 Kg

Ambient Conditions

Ambient Temperature
During Operation -40 ... +70 °C
During Storage -50 ... +80 °C
Relative Humidity Minimum 10 %
Relative Humidity At 55 °C According To Iec 60068-2-30
Maximum 95 %

Main Circuit

Number Of Poles 2
Number Of Poles For Main Current Circuit 2
Number Of No Contacts For Main Contacts 2
Number Of Nc Contacts For Main Contacts 0
Type Of Voltage Dc
Operation Al Current
At 1 Current Path At Dc-1
— At 24 V Rated Value 32 A
— At 110 V Rated Value 32 A
— At 220 V Rated Value 32 A
With 2 Current Paths In Series At Dc-1
— At 24 V Rated Value 32 A
— At 110 V Rated Value 32 A
— At 220 V Rated Value 32 A
— At 440 V Rated Value 32 A
— At 600 V Rated Value 32 A
— At 750 V Rated Value 32 A
At Dc-3 At Dc-5
— At 220 V Rated Value 32 A
— At 600 V Rated Value 21 A
— At 750 V Rated Value 7.5 A
At 1 Current Path At Dc-3 At Dc-5
— At 24 V Rated Value 32 A
— At 110 V Rated Value 32 A
— At 220 V Rated Value 32 A
With 2 Current Paths In Series At Dc-3 At Dc-5
— At 24 V Rated Value 32 A
— At 110 V Rated Value 32 A
— At 220 V Rated Value 32 A
— At 440 V Rated Value 29 A
— At 600 V Rated Value 21 A
— At 750 V Rated Value 7.5 A
Operating Power
At Dc-1
— At 110 V Rated Value 3.5 Kw
— At 220 V Rated Value 7 Kw
— At 440 V Rated Value 14 Kw
— At 750 V Rated Value 24 Kw
At Dc-3 At Dc-5
— At 110 V Rated Value 2.5 Kw
— At 220 V Rated Value 5 Kw
— At 440 V Rated Value 9 Kw
— At 600 V Rated Value 9 Kw
— At 750 V Rated Value 4 Kw
Operating Frequency
At Dc-1 Maximum 1 500 1/H
At Dc-3 Maximum 750 1/H
At Dc-5 Maximum 750 1/H
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage At Dc Rated Value 72 V
Design Of The Surge Suppressor With Varistor
Closing Power Of Magnet Coil At Dc 48 W
Holding Power Of Magnet Coil At Dc 13 W
Closing Delay At Dc 35 ... 190 Ms
Opening Delay At Dc 10 ... 25 Ms
Arcing Time 20 ... 30 Ms

Auxiliary Circuit

Number Of Nc Contacts For Auxiliary Contacts 2
Instantaneous Contact 1
Number Of No Contacts For Auxiliary Contacts 2
Instantaneous Contact 2
Number Of Co Contacts For Auxiliary Contacts 0
Identification Number And Letter For Switching Elements 21
Operation Al Current At Ac-12 Maximum 10 A
Operation Al Current At Ac-15
At 230 V Rated Value 5.6 A
At 400 V Rated Value 3.6 A
At 500 V Rated Value 2.5 A
Operation Al Current At Dc-12
At 24 V Rated Value 10 A
At 48 V Rated Value 10 A
At 60 V Rated Value 10 A
At 110 V Rated Value 3.2 A
At 125 V Rated Value 2.5 A
At 220 V Rated Value 0.9 A
At 600 V Rated Value 0.22 A
Operation Al Current At Dc-13
At 24 V Rated Value 10 A
At 48 V Rated Value 5 A
At 60 V Rated Value 5 A
At 110 V Rated Value 1.14 A
At 125 V Rated Value 0.98 A
At 220 V Rated Value 0.48 A
At 600 V Rated Value 0.07 A
Ul/Csa Ratings
Contact Rating Of Auxiliary Contacts According To Ul A600 / P600
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Main Circuit
— With Type Of Coordination 1 Required 2 X 3Na3020 (50 A) In Series (750 V, 3 Ka)
— With Type Of Assignment 2 Required 2 X 3Na3020 (50 A) In Series (750 V, 3 Ka)
For Short-Circuit Protection Of The Auxiliary Switch Required Gg: 16 A (500 V, 1 Ka)
Installation/ Mounting/ Dimensions
Mounting Position +/-22,5° Rotation Possible On Vertical Mounting Surface; Can Be Tilted Forward
And Backward By +/- 22.5° On Vertical Mounting Surface
Fastening Method Side-By-Side Mounting Yes
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail According To Din En 50022
Height 115 Mm
Width 82 Mm
Depth 145 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 15 Mm
— Backwards 0 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm
For Grounded Parts
— Forwards 30 Mm
— Backwards 0 Mm
— Upwards 10 Mm
— At The Side 10 Mm
— Downwards 10 Mm
For Live Parts
— Forwards 30 Mm
— Backwards 0 Mm
— Upwards 10 Mm
— Downwards 10 Mm
— At The Side 10 Mm

Connections/ Terminals

Type Of Electrical Connection Screw Terminal
For Main Current Circuit Screw-Type Terminals
For Auxiliary And Control Circuit Screw-Type Terminals
Type Of Connectable Conductor Cross-Sections For Main Contacts
Solid Or Stranded 2X (2,5 ... 10 Mm²)
Finely Stranded With Core End Processing 2X (1.5 ... 4 Mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
— Solid Or Stranded 2X (1 ... 2.5 Mm²)
— Finely Stranded With Core End Processing 2X (0.75 ... 1.5 Mm²)

Safety Related Data

Product Function Mirror Contact According To Iec 60947-4-1 Yes; One Nc Contact Each Must Be Connected In Series For The Right And Left
Auxiliary Switch Block Respectively
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip00

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible