This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3TK2827-1BB41

3TK2827-1BB41 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3TK2827-1BB41 Siemens

3TK2827-1BB41 Siemens - SIRIUS safety relay with relay enabling circuits (EC) 24 V DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 2NO, 0.05...3 s SC: 1NC monitored start Basic device Maximum achieved SIL: 3/2, PL: e/d

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3TK2827-1BB41
Product Description SIRIUS safety relay with relay enabling circuits (EC) 24 V DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 2NO, 0.05...3 s SC: 1NC monitored start Basic device Maximum achieved SIL: 3/2, PL: e/d
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2020
Notes Product is no longer available Sucessor:The preferred successor is 3SK1121-1CB41 If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 0,457 Kg
Packaging Dimension 53,00 x 115,50 x 125,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209449220
UPC 754554653075
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5837
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Product Function

Product Function
Automatic Start No
Light Barrier Monitoring No
Standstill Monitoring No
Protective Door Monitoring No
Magnetically Operated Switch Monitoring Nc-No No
Magnetically Operated Switch Monitoring Nc-Nc No
Rotation Speed Monitoring No
Laser Scanner Monitoring No
Light Array Monitoring No
Emergency Off Function Yes
Monitored Start-Up Yes
Pressure-Sensitive Mat Monitoring Yes
Suitability For Interaction Press Control No
Suitability For Use
Monitoring Of Floating Sensors Yes
Monitoring Of Non-Floating Sensors No
Position Switch Monitoring Yes
Emergency-Off Circuit Monitoring Yes
Valve Monitoring No
Opto-Electronic Protection Device Monitoring No
Tactile Sensor Monitoring No
Magnetically Operated Switch Monitoring No
Proximity Switch Monitoring No
Safety Switch Yes
Safety-Related Circuits Yes

General Technical Data

Certificate Of Suitability Ul Approval Yes
Product Feature Cross-Circuit-Proof Yes
Insulation Voltage Rated Value 300 V
Surge Voltage Resistance Rated Value 4 000 V
Protection Class Ip
Of The Enclosure Ip20
Of The Terminal Ip20
Shock Resistance 8G / 10 Ms
Vibration Resistance According To Iec 60068-2-6 5 ... 500 Hz: 0,075 Mm
Operating Frequency Maximum 1 000 1/H
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Electrical Endurance (Operating Cycles) Typical 100 000
Thermal Current Of The Switching Element With Contacts
Maximum 5 A
Substance Prohibitance (Date) 05/01/2012
Weight 0.457 Kg

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +80 °C
Relative Humidity During Operation 10 ... 95 %
Air Pressure According To Sn 31205 90 ... 106 Kpa

Electromagnetic Compatibility

Installation Environment Regarding Emc This Product Is Suitable For Class A Environments Only. In Household
Environments, This Device Can Cause Unwanted Radio Interference. The User Is
Required To Implement Appropriate Measures In This Case.
Emc Emitted Interference En 60947-5-1

Safety Related Data

Stop Category According To Iec 60204-1 0 + 1
Iec 62061
Sil Claim Limit (Subsystem) According To En 62061 3
Pfhd With High Demand Rate According To Iec 62061 2.7E-9 1/H
Iso 13849
Category According To En Iso 13849-1 4
Performance Level (Pl)
For Delayed Release Circuit According To Iso 13849-1 D
Iec 61508
Safety Integrity Level (Sil)
According To Iec 61508 3
For Delayed Release Circuit According To Iec 61508 Sil2
Safety Device Type According To Iec 61508-2 Type A
Average Probability Of Failure On Demand (Pfdavg) With Low
Demand Rate Acc. To Iec 615082.4E-6 1/Y
Hardware Fault Tolerance According To Iec 61508 1
T1 Value For Proof Test Interval Or Service Life According To Iec
6150820 A
Electrical Safety
Touch Protection Against Electrical Shock Finger-Safe
Short-Circuit Protection
Design Of The Fuse Link For Short-Circuit Protection Of The No
Contacts Of The Relay Outputs Requiredgl/Gg: 6 A, Or Quick: 10 A
Inputs
Design Of Input
Cascading Input/Functional Switching No
Feedback Input Yes
Start Input Yes
Number Of Sensor Inputs
1-Channel Or 2-Channel 1
Outputs
Number Of Outputs As Contact-Affected Switching Element
As Nc Contact
— For Signaling Function Instantaneous Contact 1
As No Contact
— Safety-Related Instantaneous Contact 2
— Safety-Related Delayed Switching 2
Number Of Outputs As Contact-Less Semiconductor
Switching Element
For Signaling Function
— Delayed Switching 0
— Instantaneous Contact 0
Safety-Related
— Delayed Switching 0
— Instantaneous Contact 0
Switching Capacity Current Of The No Contacts Of The Relay
Outputs For Delayed Release Circuit
At Ac-15 At 230 V 3 A
At Dc-13 At 24 V 2 A
Switching Capacity Current Of The No Contacts Of The Relay
Outputs For Instantaneous Enabling Circuit
At Ac-15 At 230 V 5 A
At Dc-13 At 24 V 5 A
Wire Length Between Sensor And Electronics Evaluation
Device With Cu 1.5 Mm² And 150 Nf/Km Maximum1 000 M
Times
Make Time With Automatic Start After Power Failure
Typical 8 000 Ms
Maximum 8 000 Ms
Make Time With Monitored Start
Maximum 80 Ms
Backslide Delay Time In The Event Of Power Failure
Maximum 100 Ms
Adjustable Off-Delay Time After Opening Of The Safety
Circuits0.05 ... 3 S
Recovery Time After Power Failure Typical 200 Ms
Pulse Duration
Of The Sensor Input Minimum 25 Ms
Of The On Pushbutton Input Minimum 0.025 S
Control Circuit/
Type Of Voltage Of The Control Supply Voltage Dc
Control Supply Voltage 1 At Dc Rated Value 24 V
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Dc
Initial Value 0.85
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value Of
Magnet Coil At Ac
At 50 Hz 0.85 ... 1.1
At 60 Hz 0.85 ... 1.1
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw And Snap-On Mounting
Height 138.5 Mm
Width 44.8 Mm
Depth 120 Mm

Connections/ Terminals

Type Of Electrical Connection Screw Terminal
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 4.0 Mm²), 2X (0.5 ... 2.5 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 2.5 Mm²), 2X (0.5 ... 1.5 Mm²)
For Awg Cables Solid 2X (20 ... 14)
For Awg Cables Stranded 2X (20 ... 14)
Connectable Conductor Cross-Section
Solid 0.5 ... 4 Mm²
Finely Stranded With Core End Processing 0.5 ... 2.5 Mm²
Awg Number As Coded Connectable Conductor Cross
Section
Solid 20 ... 14
Stranded 20 ... 14
Dc Resistance Of The Cable Maximum 30 Ω
Type Of Electrical Connection Plug-In Socket Yes

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible