This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

3UF7010-1AU00-0

3UF7010-1AU00-0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 3UF7010-1AU00-0 Siemens

3UF7010-1AU00-0 Siemens - SIMOCODE PRO V BASE, 110-240V AC/DC

Extended Description for 3UF7010-1AU00-0 Siemens

3UF7010-1AU00-0 Siemens - Outputs monostable thermistor motor protection us AC/DC 110-240v 4i/3o freely parameterizable 12 mbit/s, rs485 PROFIBUS dp-interface basic unit 2 SIMOCODE pro v

Free Delivery to UK Mainland on orders over £25

Manufacturer New

4 available
1 - 2 w.days
£560.21 Exc. VAT
£672.25 Inc. VAT

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£452.60 Exc. VAT
£543.12 Inc. VAT

Product

Article Number (Market Facing Number) 3UF7010-1AU00-0
Product Description Basic unit SIMOCODE pro V PB PROFIBUS DP interface 12 Mbit/s, RS 485, 4I/3O freely parameterizable, Us: 110...240 V AC/DC, input for thermistor connection Monostable relay outputs, expandable by extension modules
Product family SIMOCODE pro 3UF7 motor management and control devices
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,362 Kg
Packaging Dimension 52,50 x 133,00 x 133,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209593848
UPC 754554901671
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5836
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Certificate Of Suitability Ce / Ul / Csa / Ccc / C-Tick (Rcm) / Gost / Nom / Atex / Nepsi / Abs /
Dnv / Gl / Lrs / Rohs

Product Function

Current Measurement No
Voltage Measurement No
Active Power Measurement Yes
Energy Measurement No
Frequency Measurement No
Bus Communication Yes
Data Acquisition Function Yes
Diagnostics Function Yes
Password Protection Yes
Test Function Yes
Maintenance Function Yes

Product Component

Input For Thermistor Connection Yes
Digital Input Yes
Input For Analog Temperature Sensors No
Input For Ground Fault Detection No
Relay Output Yes

Product Extension

Temperature Monitoring Module Yes
Current Measuring Module Yes
Current/Voltage Measuring Module Yes
Fail-Safe Digital I/O Module Yes
Ground-Fault Monitoring Module Yes
Decoupling Module Yes
Control Unit With Display Yes
Control Unit Yes
Analog I/O Module Yes
Apparent Power Consumption 8.3 Va
Consumed Active Power 3.6 W
Insulation Voltage With Degree Of Pollution 3 At Ac Rated Value 300 V
Surge Voltage Resistance Rated Value 4 000 V
Shock Resistance
According To Iec 60068-2-27 15G / 11 Ms
Vibration Resistance 1-6 Hz / 15 Mm; 6-500 Hz / 2 G
Switching Capacity Current Of The No Contacts Of The Relay
Outputs At Ac-15
At 24 V 6 A
At 120 V 6 A
At 230 V 3 A
Switching Capacity Current Of The No Contacts Of The Relay
Outputs At Dc-13
At 24 V 2 A
At 60 V 0.55 A
At 125 V 0.25 A
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Electrical Endurance (Operating Cycles) Typical 100 000
Buffering Time In The Event Of Power Failure 0.2 S
Reference Code According To Iec 81346-2 F
Continuous Current Of The No Contacts Of The Relay Outputs
At 50 °C 6 A
At 60 °C 5 A
Type Of Input Characteristic Type 1 In Accordance With En 61131-2
Substance Prohibitance (Date) 05/01/2012
Svhc Substance Name Lead - 7439-92-1
Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.362 Kg

Electromagnetic Compatibility

Emc Emitted Interference According To Iec 60947-1 Class A
Emc Immunity According To Iec 60947-1 Corresponds To Degree Of Severity 3

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv (Power Ports) / 1 Kv (Signal Ports)
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv
Due To High-Frequency Radiation According To Iec 61000-
4-610 V
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 6 Kv Contact Discharge / 8 Kv Air Discharge
Conducted Hf Interference Emissions According To
Cispr11Corresponds To Degree Of Severity A
Field-Bound Hf Interference Emission According To Cispr11 Corresponds To Degree Of Severity A

Inputs/ Outputs

Product Function
Parameterizable Inputs Yes
Parameterizable Outputs Yes
Number Of Inputs 4
For Thermistor Connection 1
Number Of Digital Inputs With A Common Reference Potential 4
Digital Input Version
Type 1 Acc. To Iec 61131 Yes
Input Voltage At Digital Input At Dc Rated Value 24 V
Number Of Outputs 3
Number Of Semiconductor Outputs 0
Number Of Outputs As Contact-Affected Switching Element 3
Switching Behavior Monostable
Type Of Relay Outputs Monostable
Wire Length For Digital Signals Maximum 300 M
Wire Length For Thermistor Connection
With Conductor Cross-Section = 0.5 Mm² Maximum 50 M
With Conductor Cross-Section = 1.5 Mm² Maximum 150 M
With Conductor Cross-Section = 2.5 Mm² Maximum 250 M
Protective And Monitoring Functions
Product Function
Asymmetry Detection Yes
Blocking Current Evaluation Yes
Power Factor Monitoring Yes
Ground Fault Detection Yes
Ground-Fault Monitoring No
Phase Failure Detection Yes
Phase Sequence Recognition Yes
Voltage Detection Yes
Monitoring Of Number Of Start Operations Yes
Overvoltage Detection Yes
Overcurrent Detection 1 Phase Yes
Undervoltage Detection Yes
Undercurrent Detection 1 Phase Yes
Active Power Monitoring Yes
Product Function
Current Detection Yes
Overload Protection Yes
Evaluation Of Thermistor Motor Protection Yes
Total Cold Resistance Number Of Sensors In Series Maximum 1.5 K Ω
Response Value Of Thermoresistor 3 400 ... 3 800 Ω
Of The Short-Circuit Control 9 Ω
Release Value Of Thermoresistor 1 500 ... 1 650 Ω

Motor Control Functions

Product Function
Parameterizable Overload Relay Yes
Circuit Breaker Control Yes
Direct Start Yes
Reverse Starting Yes
Star-Delta Circuit Yes
Star-Delta Reversing Circuit Yes
Dahlander Circuit Yes
Dahlander Reversing Circuit Yes
Pole-Changing Switch Circuit Yes
Pole-Changing Switch Reversing Circuit Yes
Slide Control Yes
Valve Control Yes

Communication/ Protocol

Protocol Is Supported
Profibus Dp Protocol Yes
Profinet Io Protocol No
Profisafe Protocol Yes
Modbus Rtu No
Ethernet/Ip No
Opc Ua Server No
Lldp No
Address Resolution Protocol (Arp) No
Snmp No
Https No
Ntp No
Media Redundancy Protocol (Mrp) No
Number Of Interfaces
According To Profinet 0
According To Profibus 1
According To Ethernet/Ip 0
Product Function
Web Server No
Shared Device No
At The Ethernet Interface Autocrossover No
At The Ethernet Interface Autonegotiation No
At The Ethernet Interface Autosensing No
Is Supported Device Level Ring (Dlr) No
Is Supported Profinet System Redundancy (S2) No
Supports Profienergy Measured Values No
Supports Profienergy Shutdown No
Transfer Rate Maximum 12 Mbit/S
Identification & Maintenance Function
I&M0 - Device-Specific Information Yes
I&M1 - Higher Level Designation/Location Designation Yes
I&M2 - Installation Date Yes
I&M3 - Comment Yes
Type Of Electrical Connection Of The Communication Interface 9-Pin Sub-D Socket (12 Mbit) / Screw Terminal (1.5 Mbit)
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw And Snap-On Mounting
Height 111 Mm
Width 45 Mm
Depth 124 Mm
Required Spacing
Top 40 Mm
Bottom 40 Mm
Left 0 Mm
Right 0 Mm

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuityes
Type Of Electrical Connection
For Auxiliary And Control Circuit Screw-Type Terminals
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 4.0 Mm²), 2X (0.5 ... 2.5 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 2.5 Mm²), 2X (0.5 ... 1.5 Mm²)
For Awg Cables Solid 1X (20 ... 12), 2X (20 ... 14)
For Awg Cables Stranded 1X (20 ... 14), 2X (20 ... 16)
Tightening Torque With Screw-Type Terminals 0.8 ... 1.2 N·M
Tightening Torque [Lbf·In] With Screw-Type Terminals 7 ... 10.3 Lbf·In
Type Of Connectable Conductor Cross-Sections For
Profibus Wire2X 0.34 Mm², Awg 22

Ambient Conditions

Installation Altitude At Height Above Sea Level
1 Maximum 2 000 M
2 Maximum 3 000 M; Max. +50 °C (No Protective Separation)
3 Maximum 4 000 M; Max. +40 °C (No Protective Separation)
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +80 °C
During Transport -40 ... +80 °C
Environmental Category
During Operation According To Iec 60721 3K6 (No Formation Of Ice, No Condensation, Relative Humidity 10 ... 95%), 3C3
(No Salt Mist), 3S2 (Sand Must Not Get Into The Devices), 3M6
During Storage According To Iec 60721 1K6 (No Condensation, Relative Humidity 10 ... 95%), 1C2 (No Salt Mist), 1S2
(Sand Must Not Get Into The Devices), 1M4
During Transport According To Iec 60721 2K2, 2C1, 2S1, 2M2
Relative Humidity
During Operation 5 ... 95 %
Contact Rating Of Auxiliary Contacts According To Ul B300 / R300
Short-Circuit Protection
Design Of Short-Circuit Protection Per Output Fuse Links: Gg 6 A, Quick-Response 10 A (Iec 60947-5-1), Miniature Circuit-
Breaker C Char.: 1.6 A (Iec 60947-5-1) Or 6 A (I_K < 500 A)
Electrical Safety
Touch Protection Against Electrical Shock Finger-Safe
Atex
Certificate Of Suitability
Iecex Yes; Iecex Ptb 18.0004X
According To Atex Directive 2014/34/Eu Bvs 06 Atex F001, Ptb 18 Atex 5003 X
Acc. To Equipment And Protective System Intended For
Use In Potentially Explosive Atmospheres Regulations
2016 (S.I. 2016 No.1107)Its21Ukex0464, Its21Ukex0455X
According To Ukca Its21Ukex0464, Its21Ukex0455X
Explosion Device Group And Category According To Atex
Directive 2014/34/Euii (2) G, Ii (2 ) D, I (M2) / I (1G/M2), Ii (1/2) G, Ii (1G/2D)
Galvanic Isolation
(Electrically) Protective Separation According To Iec 60947-1 All Circuits With Protective Separation (Double Creepage Paths And Clearances),
The Information In The "Protective Separation" Test Report, No. A0258, Must Be
Observed (Link See Further Information)
Design Of The Electrical Isolation Protective Separation In Accordance With Iec 60947-1 For All Circuits
Note Test Report No. A0258 Must Be Observed (Link See Further Information)
Control Circuit/
Product Function Soft Starter Control Yes
Type Of Voltage Of The Control Supply Voltage Ac/Dc
Control Supply Voltage At Ac
At 50 Hz Rated Value 110 ... 240 V
At 60 Hz Rated Value 110 ... 240 V
Control Supply Voltage Frequency
1 Rated Value 50 Hz
2 Rated Value 60 Hz
Relative Symmetrical Tolerance Of The Control Supply Voltage
Frequency5 %
Control Supply Voltage At Dc Rated Value 110 ... 240 V
Operating Range Factor Control Supply Voltage Rated Value At
Dc
Initial Value 0.85
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 50 Hz
Initial Value 0.85
Full-Scale Value 1.1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 60 Hz
Initial Value 0.85
Full-Scale Value 1.1
Inrush Current Peak
At 240 V 15 A
Duration Of Inrush Current Peak
At 240 V 1 Ms

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible