Description for 3UG4624-1CS20 Siemens

3UG4624-1CS20 Siemens - Digital monitoring relay for residual current monitoring (with converter 3UL22) Setting range 10-100% of transformer rated value separate for warning threshold and switch-off value 90 to 690 V AC 50...60 Hz AC ON delay and tripping delay 0.1 to 20 s Shutdown hysteresis up to 50% Warning hysteresis 5% fixed 2 change-over contacts with or without fault buffer screw terminal Successor product: 3UG4625-1CW30 with transformer 3UL23

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3UG4624-1CS20
Product Description Digital monitoring relay for residual current monitoring (with converter 3UL22) Setting range 10-100% of transformer rated value separate for warning threshold and switch-off value 90 to 690 V AC 50...60 Hz AC ON delay and tripping delay 0.1 to 20 s Shutdown hysteresis up to 50% Warning hysteresis 5% fixed 2 change-over contacts with or without fault buffer screw terminal Successor product: 3UG4625-1CW30 with transformer 3UL23
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.02.2015
Notes Product is no longer available. Successor: 3UG4625-1CW30 3UG4625-1CW30 Compare Products Sucessor:Please note: Changed supply voltage range

Substitute information

Substitute 3UG4625-1CW30
Substitute Description Digital monitoring relay for residual current monitoring (with current transformer 3UL23) Setting range 0.03...40 A separate for warning threshold and switch-off value supply voltage 24 ... 240 V AC/DC, 50 .. 60Hz ON delay and tripping delay 0.1 to 20 s Shutdown hysteresis up to 50% Warning hysteresis 5% fixed Width 22.5 mm, 2 change-over contacts with or without fault buffer screw terminal

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 3 Day/Days
Net Weight (kg) 0,171 Kg
Packaging Dimension 29,00 x 99,00 x 107,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4011209682191
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5821
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.05.2012
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

General Technical Data

Product Function For Three-Phase Supplies
Design Of The Display Lcd
Insulation Voltage
Rated Value 690 V
For Overvoltage Category Iii According To Iec 60664
— With Degree Of Pollution 3 Rated Value 690 V
Degree Of Pollution 3
Type Of Voltage Of The Control Supply Voltage Ac
Surge Voltage Resistance Rated Value 6 Kv
Shock Resistance According To Iec 60068-2-27 Sinusoidal Half-Wave 15G / 11 Ms
Vibration Resistance According To Iec 60068-2-6 1 ... 6 Hz: 15 Mm, 6 ... 500 Hz: 2G
Mechanical Service Life (Operating Cycles) Typical 10 000 000
Electrical Endurance (Operating Cycles) At Ac-15 At 230 V
Typical100 000
Thermal Current Of The Switching Element With Contacts
Maximum 5 A
Reference Code According To Iec 81346-2 K
Relative Repeat Accuracy 1 %
Substance Prohibitance (Date) 05/01/2012
Svhc Substance Name Lead Monoxide (Lead Oxide) - 1317-36-8
Weight 0.171 Kg

Product Function

Product Function
Residual Current Display Yes
Error Memory Yes
Overcurrent Detection 1 Phase Yes
Undercurrent Detection 1 Phase No
Adjustable Open/Closed-Circuit Current Principle Yes
External Reset Yes
Control Circuit/
Control Supply Voltage At Ac
At 50 Hz Rated Value 90 ... 690 V
At 60 Hz Rated Value 90 ... 690 V
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 50 Hz
Initial Value 1
Operating Range Factor Control Supply Voltage Rated Value At
Ac At 60 Hz
Initial Value 1
Full-Scale Value 1
Measuring Circuit
Type Of Current For Monitoring Ac
Measurable Current 30 ... 40 000 Ma
Measurable Line Frequency 60 ... 50 Hz
Adjustable Operating Delay Time 0.1 ... 20 S
Adjustable Current Response Value Current
1 30 Ma ... 40 A
2 30 Ma ... 40 A
Adjustable Response Delay Time 0.1 ... 20 S
Adjustable Response Delay Time When Starting 0.1 ... 20 S
Adjustable Switching Hysteresis For Measured Current Value 15 ... 2 Ma
Buffering Time In The Event Of Power Failure Minimum 10 Ms
Accuracy Of Digital Display +/-1 Digit
Precision
Relative Metering Precision 5 %
Temperature Drift Per °C 0.1 %/°C

Auxiliary Circuit

Number Of Nc Contacts Delayed Switching 0
Number Of No Contacts For Auxiliary Contacts 0
Number Of No Contacts Delayed Switching 0
Number Of Co Contacts
For Auxiliary Contacts 2
Delayed Switching 2
Operating Frequency With 3Rt2 Contactor Maximum 5 000 1/H

Main Circuit

Type Of Voltage Ac
Operating Voltage Rated Value 17 ... 400 V
Operating Frequency Rated Value 40 ... 60 Hz
Ampacity Of The Output Relay At Ac-15
At 250 V At 50/60 Hz 3 A
At 400 V At 50/60 Hz 3 A
Ampacity Of The Output Relay At Dc-13
At 24 V 1 A
At 125 V 0.2 A
At 250 V 0.1 A
Operation Al Current At 17 V Minimum 5 Ma
Continuous Current Of The Diazed Fuse Link Of The Output
Relay4 A

Conducted Interference

Due To Burst According To Iec 61000-4-4 2 Kv
Due To Conductor-Earth Surge According To Iec 61000-4-5 2 Kv
Due To Conductor-Conductor Surge According To Iec
61000-4-51 Kv
Field-Based Interference According To Iec 61000-4-3 10 V/M
Electrostatic Discharge According To Iec 61000-4-2 6 Kv Contact Discharge / 8 Kv Air Discharge
Galvanic Isolation
Design Of The Electrical Isolation Galvanic Isolation
Galvanic Isolation
Between Input And Output Yes
Between The Outputs Yes
Between The Voltage Supply And Other Circuits Yes
Electrical Safety
Protection Class Ip On The Front According To Iec 60529 Ip20

Connections/ Terminals

Product Component Removable Terminal For Auxiliary And
Control Circuityes
Type Of Electrical Connection Screw Terminal
Type Of Connectable Conductor Cross-Sections
Solid 1X (0.5 ... 4.0 Mm²), 2X (0.5 ... 2.5 Mm²)
Finely Stranded With Core End Processing 1X (0.5 ... 2.5 Mm²), 2X (0.5 ... 1.5 Mm²)
For Awg Cables Solid 2X (20 ... 14)
For Awg Cables Stranded 2X (20 ... 14)
Connectable Conductor Cross-Section
Solid 0.5 ... 4 Mm²
Finely Stranded With Core End Processing 0.5 ... 2.5 Mm²
Awg Number As Coded Connectable Conductor Cross
Section
Solid 20 ... 14
Stranded 20 ... 14
Tightening Torque With Screw-Type Terminals 0.8 ... 1.2 N·M
Installation/ Mounting/ Dimensions
Mounting Position Any
Fastening Method Screw And Snap-On Mounting Onto 35 Mm Din Rail
Height 102 Mm
Width 22.5 Mm
Depth 91 Mm
Required Spacing
With Side-By-Side Mounting
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— Downwards 0 Mm
— At The Side 0 Mm
For Grounded Parts
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— At The Side 0 Mm
— Downwards 0 Mm
For Live Parts
— Forwards 0 Mm
— Backwards 0 Mm
— Upwards 0 Mm
— Downwards 0 Mm
— At The Side 0 Mm

Ambient Conditions

Installation Altitude At Height Above Sea Level Maximum 2 000 M
Ambient Temperature
During Operation -25 ... +60 °C
During Storage -40 ... +85 °C
During Transport -40 ... +85 °C
Environmental Footprint
Global Warming Potential [Co2 Eq] Total 17.1 Kg
Global Warming Potential [Co2 Eq] During Manufacturing 4.44 Kg
Global Warming Potential [Co2 Eq] During Operation 13.7 Kg
Global Warming Potential [Co2 Eq] After End Of Life -1.06 Kg

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible