Description for 3VA5816-7BB31-0AA0 Siemens

3VA5816-7BB31-0AA0 Siemens - molded case switch 3VA5 UL frame 1600 max short-circuit curr. rating 100kA @ 480 V 3-pole MCS110, FM, In=1600A without overload protection short circuit protection Ii=7.5 x In w/o connection self protection

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 3VA5816-7BB31-0AA0
Product Description molded case switch 3VA5 UL frame 1600 max short-circuit curr. rating 100kA @ 480 V 3-pole MCS110, FM, In=1600A without overload protection short circuit protection Ii=7.5 x In w/o connection self protection
Product family 3VA Molded Case Circuit Breakers up to 2000 A, UL / IEC
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99
Estimated dispatch time (Working Days) 35 Day/Days
Net Weight (kg) 22,900 Kg
Packaging Dimension 300,00 x 470,00 x 245,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4001869602936
UPC 195125331808
Commodity Code 85362090
LKZ_FDB/ CatalogID LV10
Product Group 5385
Group Code P360
Country of origin Mexico
Compliance with the substance restrictions according to RoHS directive Since: 09.07.2019
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Model

Product Brand Name Sentron
Product Designation Molded-Case Circuit Breaker
Product Designation / According To Ul File Cpas
Design Of The Product Molded Case Switch
Design Of The Load Switch / According To Ul 489 / Heating, Air
Conditioning, And Refrigeration Circuit Breaker (Hacr Type)Yes
Design Of The Overcurrent Release Mcs110
Protection Function Of The Overcurrent Release I
Number Of Poles 3

General Technical Data

Insulation Voltage / Rated Value 800 V
Operating Voltage / At Dc / Rated Value 750 V
Operating Voltage / At Ac / Rated Value 600 V
Power Loss [W] / Maximum 423 W
Power Loss [W] / For Rated Value Of The Current / At Ac / In Hot
Operating State / Per Pole423 W
Mechanical Service Life (Operating Cycles) / Typical 3 000
Electrical Endurance (Operating Cycles) / At Ac-1 / At 380/415 V 1 500
Electrical Endurance (Operating Cycles) / At Ac-1 / At 690 V 500
Electrical Endurance (Operating Cycles) / At 480 V 1 500
Electrical Endurance (Operating Cycles) / At 600 V 500
Product Feature / For Neutral Conductors / Upgradable/Retrofittable
/ Short-Circuit And Overload Proofno

Product Function

Communication Function No
Phase Failure Detection No
Other Measurement Function No
Net Weight 22.9 Kg

Current

Marking / According To Ul 489 / 100%-Rated Breaker No
Operation Al Current
At 40 °C 1 600 A

Switching Capacity According To Iec 60947

Switching Capacity Class Of The Circuit Breaker C
Maximum Short-Circuit Current Breaking Capacity (Icu)
At 240 V 200 Ka
At 415 V 110 Ka
At 690 V 35 Ka
Operating Short-Circuit Current Breaking Capacity (Ics)
At 240 V 100 Ka
At 415 V 55 Ka
At 690 V 17 Ka
Short-Circuit Current Making Capacity (Icm)
At 240 V 440 Ka
At 415 V 242 Ka
At 690 V 77 Ka
Design Of Short-Circuit Protection For Switching Power Values In Dc Networks, See The 3Va Molded Case Circuit
Breaker Device Manual; Link To Be Found Under Service & Support In The Last
Chapter
Switching Capacity According To Ul 489
Current Breaking Capacity
At 240 V 200 Ka
At 480 V 100 Ka
At 600 Y/347 V 65 Ka
At 600 V 65 Ka

Adjustable Parameters

Adjustable Response Value Setting Current (Ii) / For I-Tripping
Minimum 12 000 A
Maximum 12 000 A
Product Function / Grounding Protection No

Product Component

Undervoltage Release No
Trip Indicator No
Height [In] 8.14 In
Height 207 Mm
Width [In] 8.99 In
Width 228.4 Mm
Depth [In] 16 In
Depth 406.4 Mm

Connections

Type Of Electrical Connection / For Main Current Circuit Without Terminals
Design Of The Surface / Of The Connections / On The Top Of The
Switch (N, 1, 3, 5)Silver
Design Of The Surface / Of The Connections / On The Bottom Of The
Switch (N, 2, 4, 6)Silver

Auxiliary Circuit

Number Of Co Contacts / For Auxiliary Contacts 0

Environmental Conditions

Protection Class Ip / On The Front Ip40
Ambient Temperature
During Operation / Minimum -25 °C
During Operation / Maximum 70 °C
During Storage / Minimum -40 °C
During Storage / Maximum 80 °C
Reference Code / According To Iec 81346-2 F
Approvals / Certificates
General Product Approval
Confirmation
General Product Approval Emv Test Certificates Marine / Shipping
Miscellaneous
Type Test Certific-
Ates/Test Report
Other Environment
Confirmation Miscellaneous Miscellaneous Environmental Con-
Firmations

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible