6AG1131-4BD01-7AB0 Siemens - SIPLUS ET 200S EM 4DI HF based on 6ES7131-4BD01-0AB0 with conformal coating, -25…+70 °C, 5 units per packing unit,

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1131-4BD01-7AB0
Product Description SIPLUS ET 200S EM 4DI HF based on 6ES7131-4BD01-0AB0 with conformal coating, -25…+70 °C, 5 units per packing unit,
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2023
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,180 Kg
Packaging Dimension 8,00 x 9,00 x 6,40
Package size unit of measure CM
Quantity Unit 1 Package
Packaging Quantity 1

Additional Product Information

EAN 4042948460726
UPC 040892584486
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4398
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V; From Power Module
Reverse Polarity Protection Yes
Input Current
From Supply Voltage L+, Max. Dependent On Encoder
From Backplane Bus 3.3 V Dc, Max. 10 Ma
Encoder Supply
Type Of Output Voltage Min. L+ (-0.5 V), Under Load
Short-Circuit Protection Yes; Electronic
Output Current
Rated Value 500 Ma
Permissible Range, Lower Limit 0 Ma
Permissible Range, Upper Limit 500 Ma
Power Loss
Power Loss , Typ. 0.7 W
Address Area
Address Space Per Module
Address Space Per Module, Max. 1 Byte
With Packing 4 Bit
Digital Inputs
Number Of Digital Inputs 4
Input Characteristic Curve In Accordance With Iec 61131, Type 1 Yes
Input Voltage
Type Of Input Voltage Dc
Rated Value (Dc) 24 V
For Signal "0" -30 To +5 V
For Signal "1" +11 To +30V
Input Current
For Signal "1", Typ. 8 Ma
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable Yes; 0.1 / 0.5 / 3 / 15 Ms
— At "0" To "1", Min. 0.05 / 0.4 / 2.7 / 14.85
— At "0" To "1", Max. 0,15 / 0,6 / 3,3 / 15,15
— At "1" To "0", Min. 0.05 / 0.4 / 2.7 / 14.85
— At "1" To "0", Max. 0,15 / 0,6 / 3,3 / 15,15
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Encoder
Connectable Encoders
2-Wire Sensor Yes
— Permissible Quiescent Current (2-Wire Sensor), Max. 1.5 Ma
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Diagnoses
Short-Circuit Yes; Short-Circuit Of Outputs To Ground; Module By Module
Diagnostics Indication Led
Group Error Sf (Red) Yes
Status Indicator Digital Input (Green) Yes; Per Channel
Parameter
Remark 3 Byte
Diagnostics Short-Circuit Disable / Enable
Potential Separation
Potential Separation Digital Inputs
Between The Channels No
Between The Channels And Backplane Bus Yes
Isolation
Isolation Tested With 500 V Dc
Standards, Approvals, Certificates
Ce Mark Yes

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost Permitted (No Commissioning In Bedewed
State)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!

Dimensions

Width 15 Mm
Height 81 Mm
Depth 52 Mm
Weight S
Weight , Approx. 35 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible