Description for 6AG1138-4FB04-2AB0 Siemens

6AG1138-4FB04-2AB0 Siemens - SIPLUS ET 200S F-DQ 24V PROFIsafe based on 6ES7138-4FB04-0AB0 with conformal coating, -25…+60 °C, electronic module for ET 200S, 4 F-DQ PROFIsafe, 24 V DC/2 A, 30 mm overall width, up to category 4 (EN 954-1)/ SIL3 (IEC 61508)/PLE (ISO 13849), can also be used in PROFINET configurations with IM 151-3 HF

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1138-4FB04-2AB0
Product Description SIPLUS ET 200S F-DQ 24V PROFIsafe based on 6ES7138-4FB04-0AB0 with conformal coating, -25…+60 °C, electronic module for ET 200S, 4 F-DQ PROFIsafe, 24 V DC/2 A, 30 mm overall width, up to category 4 (EN 954-1)/ SIL3 (IEC 61508)/PLE (ISO 13849), can also be used in PROFINET configurations with IM 151-3 HF
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2023
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) 60 Day/Days
Net Weight (kg) 0,092 Kg
Packaging Dimension 6,50 x 9,00 x 3,50
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618045807
UPC 804766534331
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4398
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.09.2014
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Reverse Polarity Protection No
Input Current
From Load Voltage L+ (No Load), Typ. 100 Ma
From Backplane Bus 3.3 V Dc, Max. 28 Ma
Power Loss
Power Loss , Typ. 3.5 W
Digital Outputs
Type Of Digital Output Transistor
Number Of Digital Outputs 4
Short-Circuit Protection Yes
Limitation Of Inductive Shutdown Voltage To Typ. (2L+) -47 V
Control Ling A Digital Input No
Switching Capacity Of The Outputs
On Lamp Load, Max. 10 W
Load Resistance Range
Lower Limit 12 Ω
Upper Limit 1 Kω
Output Voltage
For Signal "1", Min. L+ (-2,0 V), Current Sourcing Switch: L+ (-1,5 V), Voltage Drop On Current Sinking
Switch: Max. 0.5 V
Output Current
For Signal "1" Rated Value 2 A
For Signal "1" Permissible Range, Min. 20 Ma
For Signal "1" Permissible Range, Max. 2.4 A
For Signal "0" Residual Current, Max. 0.5 Ma; Current-Sourcing And Current-Sinking Switches
Parallel Switching Of Two Outputs
For Uprating No
For Redundant Control Of A Load No
Switching Frequency
With Resistive Load, Max. 30 Hz; Symmetrical
With Inductive Load, Max. 0.1 Hz; Symmetrical
On Lamp Load, Max. 10 Hz; Symmetrical
Total Current Of The Outputs
Current Per Module, Max. 6 A
Total Current Of The Outputs (Per Group)
Horizontal Installation
— Up To 40 °C, Max. 6 A
— Up To 55 °C, Max. 5 A
— Up To 60 °C, Max. 4 A
Vertical Installation
— Up To 40 °C, Max. 4 A
Cable Length
Shielded, Max. 500 M
Unshielded, Max. 500 M
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Diagnoses
Wire-Break Yes
Short-Circuit Yes
Diagnostics Indication Led
Group Error Sf (Red) Yes
Status Indicator Digital Output (Green) Yes
Potential Separation
Potential Separation Digital Outputs
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ No
Standards, Approvals, Certificates
Highest Safety Class Achievable In Safety Mode
Acc. To En 954 4
Performance Level According To Iso 13849-1 Ple
Sil Acc. To Iec 61508 Sil 3

Ambient Temperature During Operation

Min. -25 °C
Max. 60 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!

Dimensions

Width 30 Mm
Height 81 Mm
Depth 52 Mm
Weight S
Weight , Approx. 85 G