Description for 6AG1151-7AA21-2AB0 Siemens

6AG1151-7AA21-2AB0 Siemens - SIPLUS ET 200S IM 151-7 CPU based on 6ES7151-7AA21-0AB0 with conformal coating, -25…+60 °C, ET 200S, 128 KB work memory with integrated PROFIBUS DP interface (9-pole D-sub socket) as DP Slave, without battery SIMATIC MMC required

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1151-7AA21-2AB0
Product Description SIPLUS ET 200S IM 151-7 CPU based on 6ES7151-7AA21-0AB0 with conformal coating, -25…+60 °C, ET 200S, 128 KB work memory with integrated PROFIBUS DP interface (9-pole D-sub socket) as DP Slave, without battery SIMATIC MMC required
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2023
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,251 Kg
Packaging Dimension 9,00 x 12,50 x 8,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618042400
UPC 887621294069
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4398
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.09.2014
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode No
Engineering With
Programming Package V5.5 + Sp1 Or Higher Or V5.2 + Sp1 Or Higher + Hsp 219

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes; Against Destruction
External Protection For Power Supply Lines (Recommendation) 24 V Dc/16 A Miniature Circuit Breaker With Type B And C Tripping
Characteristics. Note: A 24 V Dc/16 A Miniature Circuit Breaker With Type B
Tripping Characteristics Trips Before And With Type C Tripping Characteristic After
The Device Protection Fuse.
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Input Current
Inrush Current, Typ. 1.8 A
I²T 0.09 A²·S
From Supply Voltage 1L+, Max. 320 Ma; 410 Ma With Dp Master Module
Output Current
For Backplane Bus (5 V Dc), Max. 700 Ma
Power Loss
Power Loss , Typ. 4.2 W
Memory
Work Memory
Integrated 128 Kbyte
Expandable No
Load Memory
Plug-In (Mmc) Yes
Plug-In (Mmc), Max. 8 Mbyte
Data Management On Mmc (After Last Programming),
Min.10 A
Backup
Present Yes; Ensured By Simatic Micro Memory Card (Maintenance-Free)
Cpu Processing Times
For Bit Operations, Typ. 0.06 Μs
For Word Operations, Typ. 0.12 Μs
For Fixed Point Arithmetic, Typ. 0.16 Μs
For Floating Point Arithmetic, Typ. 0.59 Μs
Cpu-Blocks
Number Of Blocks (Total) 1 024; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be
Reduced By The Mmc Used.
Db
Number, Max. 1 024; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See S7-300 Operation List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 1; Ob 10
Number Of Delay Alarm Obs 2; Ob 20, 21
Number Of Cyclic Interrupt Obs 4; Ob 32, 33, 34, 35
Number Of Process Alarm Obs 1; Ob 40
Number Of Dpv1 Alarm Obs 3; Ob 55, 56, 57
Number Of Startup Obs 1; Ob 100
Number Of Asynchronous Error Obs 6; Ob 80, 82, 83 (For Centralized I/O Only, Not For Distributed I/O), 85, 86, 87
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 16
Additional Within An Error Ob 4
Counters, Timers And Their Retentivity
S7 Counter
Number 256
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 256
Retentivity
— Adjustable Yes
— Preset No Retentivity
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 64 Kbyte
Flag
Size, Max. 256 Byte
Retentivity Available Yes; Mb 0 To Mb 255
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; 1 Memory Byte
Data Blocks
Retentivity Adjustable Yes; Via Non-Retain Property On Db
Retentivity Preset Yes
Local Data
Per Priority Class, Max. 32 Kbyte; Max. 2048 Bytes Per Block
Address Area
I/O Address Area
Inputs 2 048 Byte
Outputs 2 048 Byte
Of Which Distributed
— Inputs 2 048 Byte
— Outputs 2 048 Byte
Process Image
Inputs 2 048 Byte
Outputs 2 048 Byte
Inputs, Adjustable 2 048 Byte
Outputs, Adjustable 2 048 Byte
Inputs, Default 128 Byte
Outputs, Default 128 Byte
Digital Channels
Inputs 16 336
— Of Which Central 496
Outputs 16 336
— Of Which Central 496
Analog Channels
Inputs 1 021
— Of Which Central 124
Outputs 1 021
— Of Which Central 124
Hardware Configuration
Number Of Modules Per System, Max. 63; Centralized
Mounting Rail
Number Of Mounting Rails That Can Be Used 1
Length Of Mounting Rail, Max. Station Width: ≤ 1 M Or < 2 M
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Backup Time 6 Wk; At 40 °C Ambient Temperature, Typically
Deviation Per Day, Max. 10 S; Typ.: 2 S
Behavior Of The Clock Following Power-On Clock Continues Running After Power Off
Behavior Of The Clock Following Expiry Of Backup Period The Clock Continues At The Time Of Day It Had When Power Was Switched Off
Operating Hours Counter
Number 1
Number/Number Range 0
Range Of Values 0 To 2^31 Hours (When Using Sfc 101)
Granularity 1 H
Retentive Yes; Must Be Restarted At Each Restart
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes; With Dp Slave Only Slave Clock
On Dp, Device Yes
In As, Master No
In As, Device No
Interfaces
Interfaces/Bus Type 1 X Mpi/Profibus Dp
1. Interface
Interface Type Integrated Rs 485 Interface
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 80 Ma
Protocols
Mpi Yes
Profibus Dp Master No
Profibus Dp Device Yes; Active / Passive
Point-To-Point Connection No
Mpi
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes; With Master Module
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes; Only Server, Configured On One Side
— S7 Communication, As Client No
— S7 Communication, As Server Yes
1St Interface / Profibus Dp Device / Header
Gsd File The Latest Gsd File Is Available On The Internet
(Http://Www.Siemens.Com/Profibus-Gsd)
Transmission Rate, Max. 12 Mbit/S
Automatic Baud Rate Search Yes; Only With Passive Interface
Address Area, Max. 32
User Data Per Address Area, Max. 32 Byte; Up To Max. Size Of The Transfer Memory
Services
— Pg/Op Communication Yes
— Routing Yes; Only With Active, Integrated Dp Slave Interface And Inserted Dp Master
Module In Dp Master Mode
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes; Only Server, Configured On One Side
— S7 Communication, As Client No
— S7 Communication, As Server Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
2. Interface
Interface Type External Interface Via Master Module 6Es7138-4Ha00-0Ab0
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. No
Protocols
Mpi No
Profibus Dp Master Yes
Profibus Dp Device No
Profibus Dp Master
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32; Per Station
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication Yes; I Blocks Only
— S7 Communication Yes; Only Server, Configured On One Side
— S7 Communication, As Client No
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode No
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Max. Number Of Dp Devices That Can Be
Activated/Deactivated At The Same Time8
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
User Data Per Dp Device
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
Protocols
Open Ie Communication
Tcp/Ip No
Communication Functions / Header
Pg/Op Communication Yes
Data Record Routing Yes; With Dp Master Module
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 8
Number Of Gd Packets, Max. 8
Number Of Gd Packets, Transmitter, Max. 8
Number Of Gd Packets, Receiver, Max. 8
Size Of Gd Packets, Max. 22 Byte
Size Of Gd Packet (Of Which Consistent), Max. 22 Byte
S7 Basic Communication
Supported Yes
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 76 Byte; 76 Bytes (With X_Send Or X_Rcv); 64 Bytes (With X_Put Or X_Get
As Server)
S7 Communication
Supported Yes
As Server Yes
As Client No
User Data Per Job, Max. See Online Help Of Step 7 (Shared Parameters Of The Sfbs/Fbs And Of The
Sfcs/Fcs Of S7 Communication)
User Data Per Job (Of Which Consistent), Max. See Online Help Of Step 7 (Shared Parameters Of The Sfbs/Fbs And Of The
Sfcs/Fcs Of S7 Communication)
Number Of Connections
Overall 12
Usable For Pg Communication 11
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Min. 1
— Adjustable For Pg Communication, Max. 11
Usable For Op Communication 11
— Reserved For Op Communication 1
— Adjustable For Op Communication, Min. 1
— Adjustable For Op Communication, Max. 11
Usable For S7 Basic Communication 10
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Min. 0
— Adjustable For S7 Basic Communication, Max. 10
Usable For Routing 4; As Slave Only With Active Interface, With Im 151-7 Cpu As Dp Master
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 12; Depending On The Configured Connections For Pg/Op And S7 Basic

Communication

Process Diagnostic Messages Yes; Alarm_S, Alarm_Sc, Alarm_Sq, Alarm_D, Alarm_Dq
Simultaneously Active Alarm-S Blocks, Max. 300
Test Commissioning Functions
Status Block Yes; Up To 2 Simultaneously
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max. 30
— Of Which Status Variables, Max. 30
— Of Which Control Variables, Max. 14
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs
Number Of Variables, Max. 10
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 500
— Adjustable No
— Of Which Powerfail-Proof 100; Only The Last 100 Entries Are Retained
Number Of Entries Readable In Run, Max. 499
— Adjustable Yes; From 10 To 499
Preset 10
Service Data
Can Be Read Out Yes
Interrupts/Diagnostics/Status Information
Alarms Yes
Diagnostics Function Yes
Diagnostics Indication Led
Group Error Sf (Red) Yes
Monitoring 24 V Voltage Supply On (Green) Yes
Potential Separation
Between Profibus Dp And All Other Circuit Components Yes
Isolation
Isolation Tested With 500 V Dc
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ce Mark Yes

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 60 °C; = Tmax
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Configuration / Header
Configuration Rules Max. 63 Peripheral Modules Per Station; Station Width < 1 M Or < 2 M; Max. 10 A
Per Load Group (Power Module); Master Interface Module On Right Next To Im
151-7 Cpu (X2 Interface)
Configuration Software
Step 7 Lite No
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes; Optional
— Cfc Yes; Optional
— Graph Yes; Optional
— Higraph® Yes; Optional
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy
Programming / Cycle Time Monitoring / Header
Lower Limit 1 Ms
Upper Limit 6 000 Ms
Adjustable Yes
Preset 150 Ms

Dimensions

Width 60 Mm; Dp Master Module: 35 Mm
Height 119.5 Mm
Depth 75 Mm
Weight S
Weight , Approx. 200 G; Dp Master Module: Approx. 100 G