Description for 6AG1151-8FB01-2AB0 Siemens

6AG1151-8FB01-2AB0 Siemens - ***spare part*** SIPLUS ET 200S IM 151-8F PN/DP based on 6ES7151-8FB01-0AB0 with conformal coating, -25…+60 °C CPU for ET 200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO Controller/I-device without battery, MMC required

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1151-8FB01-2AB0
Product Description ***spare part*** SIPLUS ET 200S IM 151-8F PN/DP based on 6ES7151-8FB01-0AB0 with conformal coating, -25…+60 °C CPU for ET 200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO Controller/I-device without battery, MMC required
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2022
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,410 Kg
Packaging Dimension 15,00 x 13,00 x 8,80
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4042948586907
UPC 804766056178
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4572
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode No
Engineering With
Programming Package Step 7 V5.5 Or Higher, Distributed Safety V5.4 Sp4

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes; Against Destruction
External Protection For Power Supply Lines (Recommendation) 24 V Dc/16 A Miniature Circuit Breaker With Type B And C Tripping
Characteristics. Note: A 24 V Dc/16 A Miniature Circuit Breaker With Type B
Tripping Characteristics Trips Before And With Type C Tripping Characteristic After
The Device Protection Fuse.
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Input Current
Inrush Current, Typ. 1.8 A
I²T 0.13 A²·S
From Supply Voltage 1L+, Max. 352 Ma; 426 Ma With Dp Master Module
Output Current
For Backplane Bus (5 V Dc), Max. 700 Ma
Power Loss
Power Loss , Typ. 5.5 W
Memory
Work Memory
Integrated 256 Kbyte; For Program And Data
Expandable No
Load Memory
Plug-In (Mmc) Yes
Plug-In (Mmc), Max. 8 Mbyte
Data Management On Mmc (After Last Programming),
Min.10 A
Backup
Present Yes; Ensured By Simatic Micro Memory Card (Maintenance-Free)
Cpu Processing Times
For Bit Operations, Typ. 0.06 Μs
For Word Operations, Typ. 0.12 Μs
For Fixed Point Arithmetic, Typ. 0.16 Μs
For Floating Point Arithmetic, Typ. 0.59 Μs
Cpu-Blocks
Number Of Blocks (Total) 1 024; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be
Reduced By The Mmc Used.
Db
Number, Max. 1 024; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See S7-300 Operation List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 1; Ob 10
Number Of Delay Alarm Obs 2; Ob 20, 21
Number Of Cyclic Interrupt Obs 4; Ob 32, 33, 34, 35
Number Of Process Alarm Obs 1; Ob 40
Number Of Dpv1 Alarm Obs 3; Ob 55, 56, 57
Number Of Isochronous Mode Obs 1; Ob 61; Only For Profinet
Number Of Startup Obs 1; Ob 100
Number Of Asynchronous Error Obs 6; Ob 80, 82, 83, 85, 86, 87 (Ob83 Only For Centralized I/O And Profinet Io)
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 16
Additional Within An Error Ob 4
Counters, Timers And Their Retentivity
S7 Counter
Number 256
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Adjustable Yes
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 256
Retentivity
— Adjustable Yes
— Preset No Retentivity
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 64 Kbyte
Flag
Size, Max. 256 Byte
Retentivity Available Yes
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; 1 Memory Byte
Data Blocks
Retentivity Adjustable Yes; Via Non-Retain Property On Db
Retentivity Preset Yes
Local Data
Per Priority Class, Max. 32 768 Byte; Max. 2048 Bytes Per Block
Address Area
I/O Address Area
Inputs 2 048 Byte
Outputs 2 048 Byte
Of Which Distributed
— Inputs 2 048 Byte
— Outputs 2 048 Byte
Process Image
Inputs, Adjustable 2 048 Byte
Outputs, Adjustable 2 048 Byte
Inputs, Default 128 Byte
Outputs, Default 128 Byte
Subprocess Images
Number Of Subprocess Images, Max. 1; With Profinet Io, The Length Of The User Data Is Limited To 1600 Bytes
Digital Channels
Inputs 16 336
— Of Which Central 496
Outputs 16 336
— Of Which Central 496
Analog Channels
Inputs 1 021
— Of Which Central 124
Outputs 1 021
— Of Which Central 124
Hardware Configuration
Number Of Modules Per System, Max. 63; Centralized
Mounting Rail
Number Of Mounting Rails That Can Be Used 1
Length Of Mounting Rail, Max. Station Width: ≤ 1 M Or < 2 M
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Backup Time 6 Wk; At 40 °C Ambient Temperature, Typically
Deviation Per Day, Max. 10 S; Typ.: 2 S
Behavior Of The Clock Following Power-On Clock Continues Running After Power Off
Behavior Of The Clock Following Expiry Of Backup Period The Clock Continues At The Time Of Day It Had When Power Was Switched Off
Operating Hours Counter
Number 1
Number/Number Range 0
Range Of Values 0 To 2^31 Hours (When Using Sfc 101)
Granularity 1 H
Retentive Yes; Must Be Restarted At Each Restart
Clock Synchronization
Supported Yes
To Mpi, Master No
On Mpi, Device No
To Dp, Master Yes; With Dp Master Module
On Dp, Device Yes; With Dp Master Module
In As, Master No
In As, Device No
On Ethernet Via Ntp Yes; As Client
1. Interface
Interface Type Profinet
Isolated Yes
Automatic Detection Of Transmission Rate Yes
Autonegotiation Yes
Autocrossing Yes
Change Of Ip Address At Runtime, Supported Yes
Interface Types
Rj 45 (Ethernet) Yes
Number Of Ports 3; Rj45
Integrated Switch Yes
Protocols
Mpi No
Profinet Io Controller Yes; Also Simultaneously With Io-Device Functionality
Profinet Io Device Yes; Also Simultaneously With Io Controller Functionality
Profinet Cba Yes
Profibus Dp Master No
Profibus Dp Device No
Open Ie Communication Yes; Via Tcp/Ip, Iso On Tcp, And Udp
Web Server Yes
Point-To-Point Connection No
Profinet Io Controller
Transmission Rate, Max. 100 Mbit/S; Full Duplex
Services
— Pg/Op Communication Yes
— Routing Yes; With Dp Master Module
— S7 Communication Yes; With Loadable Fbs
— Isochronous Mode Yes; Ob 61; Only For Profinet Io
— Irt Yes
— Shared Device Yes
— Prioritized Startup Yes
— Number Of Io Devices With Prioritized Startup, Max. 32
— Number Of Connectable Io Devices, Max. 128
— Of Which Io Devices With Irt, Max. 64
— Of Which In Line, Max. 64
— Number Of Io Devices With Irt And The Option "High
Flexibility"128
— Of Which In Line, Max. 61
— Number Of Connectable Io Devices For Rt, Max. 128
— Of Which In Line, Max. 128
— Activation/Deactivation Of Io Devices Yes
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Io Devices Changing During Operation (Partner
Ports), Supportedyes
— Number Of Io Devices Per Tool, Max. 8
— Device Replacement Without Swap Medium Yes
— Send Cycles 250 Μ S, 500 Μs,1 Ms; 2 Ms, 4 Ms (Not In The Case Of Irt With "High Flexibility"
Option)
— Updating Time Minimum Value Depends On Communication Share Set For Profinet I/O, On
The Number Of I/O Devices, And On The Number Of Configured User Data Items.
— Updating Times 250 Μs To 512 Ms (Depends On Operating Mode; For More Details, Refer To
Operating Instructions, "Interface Module Im151-8 Pn/Dp Cpu")
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
— User Data Consistency, Max. 1 024 Byte; With Profinet I/O
Profinet Io Device
Services
— Pg/Op Communication Yes
— Routing Yes
— S7 Communication Yes; With Loadable Fbs
— Isochronous Mode No
— Irt Yes
— Profienergy Yes; With Sfb 73 / 74 Prepared For Loadable Profienergy Standard Fb For I-
Device
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 2
Transfer Memory
— Inputs, Max. 1 440 Byte; Per Io Controller With Shared Device
— Outputs, Max. 1 440 Byte; Per Io Controller With Shared Device
Submodules
— Number Of Submodules / At The 1St Interface / As
Profinet Io Device / Maximum64
— User Data Per Submodule, Max. 1 024 Byte
Profinet Cba
Acyclic Transmission Yes
Cyclic Transmission Yes
Open Ie Communication
Number Of Connections, Max. 8
Local Port Numbers Used At The System End 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532,
65533, 65534, 65535
2. Interface
Interface Type External Interface Via Master Module 6Es7138-4Ha00-0Ab0
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. No
Protocols
Mpi No
Profinet Io Controller No
Profinet Io Device No
Profinet Cba No
Profibus Dp Master Yes
Profibus Dp Device No
Open Ie Communication No
Web Server No
Profibus Dp Master
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32; Per Station
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication Yes; I Blocks Only
— S7 Communication Yes
— S7 Communication, As Client No
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode No
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Max. Number Of Dp Devices That Can Be
Activated/Deactivated At The Same Time8
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 2 048 Byte
— Outputs, Max. 2 048 Byte
User Data Per Dp Device
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
Protocols
Redundancy Mode
Media Redundancy
— Mrp Yes
— Switchover Time On Line Break, Typ. 200 Ms; Profinet Mrp
— Number Of Stations In The Ring, Max. 50
Open Ie Communication
Tcp/Ip Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 8
— Data Length For Connection Type 01H, Max. 1 460 Byte
— Data Length For Connection Type 11H, Max. 32 768 Byte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 8
— Data Length, Max. 32 768 Byte
Udp Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 8
— Data Length, Max. 1 472 Byte
Web Server
Supported Yes
User-Defined Websites Yes
Number Of Http Clients 5
Communication Functions / Header
Pg/Op Communication Yes
Data Record Routing Yes; With Dp Master Module
Global Data Communication
Supported No
S7 Basic Communication
Supported Yes; I Blocks
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 76 Byte
S7 Communication
Supported Yes
As Server Yes
As Client Yes; Via Integrated Profinet Interface And Loadable Fbs
User Data Per Job, Max. See Online Help Of Step 7 (Shared Parameters Of The Sfbs/Fbs And Of The
Sfcs/Fcs Of S7 Communication)
Communication Functions / Profinet Cba (With Set Target Load) / Header
Setpoint For The Cpu Communication Load 50 %
Number Of Remote Interconnection Partners 32
Number Of Master/Device Functions 30
Total Of All Master/Device Connections 1 000
Data Length Of All Incoming Master/Device Connections,
Max.4 000 Byte
Data Length Of All Outgoing Master/Device Connections,
Max.4 000 Byte
Number Of Device-Internal And Profibus
Interconnections500
Data Length Of Device-Internal Und Profibus
Interconnections, Max.4 000 Byte
Data Length Per Connection, Max. 1 400 Byte
Performance Data / Profinet Cba / Remote Interconnection / With Acyclic Transfer / Header
— Sampling Interval, Min. 500 Ms
— Number Of Incoming Interconnections 100
— Number Of Outgoing Interconnections 100
— Data Length Of All Incoming Interconnections, Max. 2 000 Byte
— Data Length Of All Outgoing Interconnections, Max. 2 000 Byte
— Data Volume / As User Data For Remote
Interconnections / In The Case Of Acyclic Transmission /
With Profinet Cba / Per Connection / Maximum1 400 Byte
Performance Data / Profinet Cba / Remote Interconnection / With Cyclic Transfer / Header
— Transmission Frequency: Transmission Interval, Min. 1 Ms
— Number Of Incoming Interconnections 200
— Number Of Outgoing Interconnections 200
— Data Length Of All Incoming Interconnections, Max. 2 000 Byte
— Data Length Of All Outgoing Interconnections, Max. 2 000 Byte
— Data Volume / As User Data For Remote
Interconnections / With Cyclical Transfer / With
Profinet Cba / Per Connection / Maximum450 Byte
Performance Data / Profinet Cba / Hmi Variables Via Profinet / Acyclic / Header
— Number Of Stations That Can Log On For Hmi Variables
(Pn Opc/Imap)3; 2X Pn Opc/1X Imap
— Hmi Variable Updating 500 Ms
— Number Of Hmi Variables 200
— Data Length Of All Hmi Variables, Max. 2 000 Byte
Performance Data / Profinet Cba / Profibus Proxy Functionality / Header
— Supported Yes
— Number Of Linked Profibus Devices 16
— Data Length Per Connection, Max. 240 Byte; Slave-Dependent
Ipar Server
Supported Yes
Number Of Connections
Overall 12
Usable For Pg Communication 11
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Min. 1
— Adjustable For Pg Communication, Max. 11
Usable For Op Communication 11
— Reserved For Op Communication 1
— Adjustable For Op Communication, Min. 1
— Adjustable For Op Communication, Max. 11
Usable For S7 Basic Communication 10
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Min. 0
— Adjustable For S7 Basic Communication, Max. 10
Usable For S7 Communication 10; With Loadable Fbs
— Adjustable For S7 Communication, Max. 10
Total Number Of Instances, Max. 32
Usable For Routing 4; Max.
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 12; Depending On The Configured Connections For Pg/Op And S7 Basic

Communication

Process Diagnostic Messages Yes; Alarm_S, Alarm_Sc, Alarm_Sq, Alarm_D, Alarm_Dq
Simultaneously Active Alarm-S Blocks, Max. 300
Test Commissioning Functions
Status Block Yes; Up To 2 Simultaneously
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max. 30
— Of Which Status Variables, Max. 30
— Of Which Control Variables, Max. 14
Forcing
Forcing Yes
Forcing, Variables I/O
Number Of Variables, Max. 10
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 500
— Adjustable No
— Of Which Powerfail-Proof 100; Only The Last 100 Entries Are Retained
Interrupts/Diagnostics/Status Information
Alarms Yes
Diagnostics Function Yes
Diagnostics Indication Led
For Maintenance Yes; Mt
Bus Fault Bf (Red) Yes; Bf-Pn
Group Error Sf (Red) Yes
Monitoring 24 V Voltage Supply On (Green) Yes
Bus Activity Profinet (Green) Yes; P1-/P2-/P3-Link
Potential Separation
Between Profibus Dp And All Other Circuit Components Yes
Isolation
Isolation Tested With 500 V Dc
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ce Mark Yes
Rcm (Formerly C-Tick) Yes

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 60 °C; = Tmax
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Configuration / Header
Configuration Software
Step 7 Yes; V5.5 Or Higher
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes; Optional
— Cfc Yes; Optional
— Graph Yes; Optional
— Higraph® Yes; Optional
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy
Programming / Cycle Time Monitoring / Header
Lower Limit 1 Ms
Upper Limit 6 000 Ms
Adjustable Yes
Preset 150 Ms

Dimensions

Width 120 Mm; Dp Master Module: 35 Mm
Height 119.5 Mm
Depth 75 Mm
Weight S
Weight , Approx. 320 G; Dp Master Module: Approx. 100 G