Description for 6AG1223-1BL32-2XB0 Siemens

6AG1223-1BL32-2XB0 Siemens - SIPLUS S7-1200 SM 1223 16DI/16DQ based on 6ES7223-1BL32-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, digital input/output 16 DI/16 DQ, 16 DI 24 V DC, sink/source, 16 DQ, transistor 0.5 A

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£598.84 Exc. VAT
£718.61 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1223-1BL32-2XB0
Product Description SIPLUS S7-1200 SM 1223 16DI/16DQ based on 6ES7223-1BL32-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, digital input/output 16 DI/16 DQ, 16 DI 24 V DC, sink/source, 16 DQ, transistor 0.5 A
Product family SIPLUS SM 1223 digital input/output modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,310 Kg
Packaging Dimension 9,00 x 109,00 x 8,60
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618046439
UPC 887621884253
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4578
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 15.03.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
From Backplane Bus 5 V Dc, Max. 185 Ma
Digital Inputs
From Load Voltage L+ (Without Load), Max. 4 Ma; Per Channel
Output Voltage / Header
Supply Voltage Of The Transmitters / Header
Present Yes
Power Loss
Power Loss , Typ. 4.5 W
Digital Inputs
Number Of Digital Inputs 16
In Groups Of 2
Input Characteristic Curve In Accordance With Iec 61131, Type 1 Yes
Number Of Simultaneously Controllable Inputs
All Mounting Positions
— Up To 40 °C, Max. 16
Horizontal Installation
— Up To 40 °C, Max. 16
— Up To 50 °C, Max. 16
Vertical Installation
— Up To 40 °C, Max. 16
Input Voltage
Type Of Input Voltage Dc
Rated Value (Dc) 24 V
For Signal "0" 5 V Dc At 1 Ma
For Signal "1" 15 V Dc At 2.5 Ma
Input Current
For Signal "0", Max. (Permissible Quiescent Current) 1 Ma
For Signal "1", Min. 2.5 Ma
For Signal "1", Typ. 4 Ma
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable Yes; 0.2 Ms, 0.4 Ms, 0.8 Ms, 1.6 Ms, 3.2 Ms, 6.4 Ms And 12.8 Ms, Selectable In
Groups Of Four
For Interrupt Inputs
— Parameterizable Yes
Cable Length
Shielded, Max. 500 M
Unshielded, Max. 300 M
Digital Outputs
Number Of Digital Outputs 16
In Groups Of 1
Short-Circuit Protection No; To Be Provided Externally
Limitation Of Inductive Shutdown Voltage To L+ (-48 V)
Switching Capacity Of The Outputs
With Resistive Load, Max. 0.5 A
On Lamp Load, Max. 5 W
Output Voltage
Rated Value (Dc) 24 V
For Signal "0", Max. 0.1 V; With 10 Kohm Load
For Signal "1", Min. 20 V Dc
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "1" Permissible Range, Max. 0.5 A
For Signal "0" Residual Current, Max. 10 Μa
Output Delay With Resistive Load
"0" To "1", Max. 50 Μs
"1" To "0", Max. 200 Μs
Total Current Of The Outputs (Per Group)
Horizontal Installation
— Up To 50 °C, Max. 8 A; Current Per Mass
Relay Outputs
Switching Capacity Of Contacts
— With Inductive Load, Max. 0.5 A
— On Lamp Load, Max. 5 W
— With Resistive Load, Max. 0.5 A
Cable Length
Shielded, Max. 500 M
Unshielded, Max. 150 M
Interrupts/Diagnostics/Status Information
Alarms Yes
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Diagnostics Indication Led
For Status Of The Inputs Yes
For Status Of The Outputs Yes
For Maintenance Yes
Potential Separation
Potential Separation Digital Inputs
Between The Channels, In Groups Of 2
Potential Separation Digital Outputs
Between The Channels, In Groups Of 1
Between The Channels And Backplane Bus 500 V Ac
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 123 Kg
— Global Warming Potential, (During Production) [Co2
Eq]12.1 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]111 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-0.434 Kg

Ambient Conditions

Free Fall
Fall Height, Max. 0.3 M; Five Times, In Product Package

Ambient Temperature During Operation

Min. -40 °C; = Tmin (Incl. Condensation/Frost); Start-Up @ -25 °C
Max. 70 °C; = Tmax; Tmax > +60 °C Number Of Simultaneously Activated Outputs 8,
Inputs 8 (No Adjacent Points) For Horizontal Mounting Position
At Cold Restart, Min. -25 °C
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A
Connection Method
Required Front Connector Yes
Mechanics/Material
Enclosure Material (Front)
Plastic Yes

Dimensions

Width 70 Mm
Height 100 Mm
Depth 75 Mm
Weight S
Weight , Approx. 310 G