Description for 6AG1231-5QF32-4XB0 Siemens

6AG1231-5QF32-4XB0 Siemens - SIPLUS S7-1200 SM 1231 TC 8 AI based on 6ES7231-5QF32-0XB0 with conformal coating, -20…+60 °C, analog input, SM 1231 TC 8 AI thermocouples

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£664.30 Exc. VAT
£797.16 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1231-5QF32-4XB0
Product Description SIPLUS S7-1200 SM 1231 TC 8 AI based on 6ES7231-5QF32-0XB0 with conformal coating, -20…+60 °C, analog input, SM 1231 TC 8 AI thermocouples
Product family SIPLUS SM 1231 thermocouple module
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,196 Kg
Packaging Dimension 9,00 x 10,70 x 5,80
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618053413
UPC 804766080678
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4578
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 30.08.2013
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Input Current
Current Consumption, Typ. 40 Ma
From Backplane Bus 5 V Dc, Typ. 80 Ma
Power Loss
Power Loss , Typ. 1.5 W

Analog Inputs

Number Of Analog Inputs 4; Thermocouples
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.±35 V
Technical Unit For Temperature Measurement Adjustable Degrees Celsius/Degrees Fahrenheit
Input Ranges
Voltage No
Current No
Thermocouple Yes; J, K, T, E, R & S, B, N, C, Txk/Xk(L); Voltage Range: ±80 Mv
Resistance Thermometer No
Resistance No
Input Ranges (Rated Values), Voltages
-80 Mv To +80 Mv Yes
— Input Resistance (-80 Mv To +80 Mv) ≥1 Mohm
Input Ranges (Rated Values), Thermocouples
Type B Yes
Type C Yes
Type E Yes
Type J Yes
Type K Yes
Type N Yes
Type R Yes
Type S Yes
Type T Yes
Type Txk/Txk(L) To Gost Yes
Thermocouple (Tc)
Temperature Compensation
— Parameterizable No
Analog Value Generation For The Inputs
Measurement Principle Integrating
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 15 Bit; + Sign
Integration Time, Parameterizable No
Interference Voltage Suppression For Interference
Frequency F1 In Hz85 Db At 50 / 60 / 400 Hz
Smoothing Of Measured Values
Parameterizable Yes
Errors/Accuracies
Temperature Error (Relative To Input Range), (+/-) 25 °C ±0.1%, To 55 °C ±0.2% Total Measurement Range
Repeat Accuracy In Steady State At 25 °C (Relative To Output
Range), (+/-)0.5 %
Interference Voltage Suppression For F = N X (F1 +/- 1 %), F1 = Interference Frequency
Common Mode Interference, Min. 120 Db
Interrupts/Diagnostics/Status Information
Alarms Yes
Diagnostics Function Yes; Can Be Read Out
Alarms
Diagnostic Alarm Yes
Diagnoses
Monitoring The Supply Voltage Yes
Wire-Break Yes
Diagnostics Indication Led
For Status Of The Inputs Yes
For Maintenance Yes
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 43.1 Kg
— Global Warming Potential, (During Production) [Co2
Eq]7.62 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]36 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-0.544 Kg

Ambient Conditions

Free Fall
Fall Height, Max. 0.3 M; Five Times, In Product Package

Ambient Temperature During Operation

Min. -20 °C; = Tmin (Incl. Condensation/Frost); Start-Up @ 0 °C
Max. 60 °C; = Tmax
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A
Connection Method
Required Front Connector Yes
Mechanics/Material
Enclosure Material (Front)
Plastic Yes

Dimensions

Width 45 Mm
Height 100 Mm
Depth 75 Mm
Weight S
Weight , Approx. 220 G

Documentation