This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1315-2AH14-7AB0

6AG1315-2AH14-7AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1315-2AH14-7AB0 Siemens

6AG1315-2AH14-7AB0 Siemens - SIPLUS S7-300 CPU 315-2DP based on 6ES7315-2AH14-0AB0 with conformal coating, -25…+70 °C, central processing unit with MPI integrated power supply 24 V DC work memory 256 KB 2nd interface DP master/ slave Micro Memory Card required

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1315-2AH14-7AB0
Product Description SIPLUS S7-300 CPU 315-2DP based on 6ES7315-2AH14-0AB0 with conformal coating, -25…+70 °C, central processing unit with MPI integrated power supply 24 V DC work memory 256 KB 2nd interface DP master/ slave Micro Memory Card required
Product family SIPLUS S7-300 CPU 315-2 DP
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,361 Kg
Packaging Dimension 15,00 x 13,00 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4042948510827
UPC 662643892321
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode Yes
Engineering With
Programming Package Step 7 V5.5 + Sp1 Or Higher Or Step 7 V5.2 + Sp1 Or Higher With Hsp 218

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
External Protection For Power Supply Lines (Recommendation) 2 A Min.
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Repeat Rate, Min. 1 S
Input Current
Current Consumption (Rated Value) 850 Ma
Current Consumption (In No-Load Operation), Typ. 150 Ma
Inrush Current, Typ. 3.5 A
I²T 1 A²·S
Power Loss
Power Loss , Typ. 4.5 W
Memory
Work Memory
Integrated 256 Kbyte
Expandable No
Load Memory
Plug-In (Mmc) Yes
Plug-In (Mmc), Max. 8 Mbyte
Data Management On Mmc (After Last Programming),
Min.10 A
Backup
Present Yes; Guaranteed By Mmc (Maintenance-Free)
Without Battery Yes; Program And Data
Cpu Processing Times
For Bit Operations, Typ. 0.05 Μs
For Word Operations, Typ. 0.09 Μs
For Fixed Point Arithmetic, Typ. 0.12 Μs
For Floating Point Arithmetic, Typ. 0.45 Μs
Cpu-Blocks
Number Of Blocks (Total) 1 024; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be
Reduced By The Mmc Used.
Db
Number, Max. 1 024; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See Instruction List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 1; Ob 10
Number Of Delay Alarm Obs 2; Ob 20, 21
Number Of Cyclic Interrupt Obs 4; Ob 32, 33, 34, 35
Number Of Process Alarm Obs 1; Ob 40
Number Of Dpv1 Alarm Obs 3; Ob 55, 56, 57
Number Of Isochronous Mode Obs 1; Ob 61
Number Of Startup Obs 1; Ob 100
Number Of Asynchronous Error Obs 5; Ob 80, 82, 85, 86, 87
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 16
Additional Within An Error Ob 4
Counters, Timers And Their Retentivity
S7 Counter
Number 256
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 256
Retentivity
— Adjustable Yes
— Preset No Retentivity
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 128 Kbyte
Flag
Size, Max. 2 048 Byte
Retentivity Available Yes; Mb 0 To Mb 2 047
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; 1 Memory Byte
Data Blocks
Retentivity Adjustable Yes; Via Non-Retain Property On Db
Retentivity Preset Yes
Local Data
Per Priority Class, Max. 32 Kbyte; Max. 2 Kb Per Block
Address Area
I/O Address Area
Inputs 2 048 Byte
Outputs 2 048 Byte
Of Which Distributed
— Inputs 2 048 Byte
— Outputs 2 048 Byte
Process Image
Inputs 2 048 Byte
Outputs 2 048 Byte
Inputs, Adjustable 2 048 Byte
Outputs, Adjustable 2 048 Byte
Inputs, Default 128 Byte
Outputs, Default 128 Byte
Subprocess Images
Number Of Subprocess Images, Max. 1
Digital Channels
Inputs 16 384
— Of Which Central 1 024
Outputs 16 384
— Of Which Central 1 024
Analog Channels
Inputs 1 024
— Of Which Central 256
Outputs 1 024
— Of Which Central 256
Hardware Configuration
Number Of Expansion Units, Max. 3
Number Of Dp Masters
Integrated 1
Via Cp 4
Number Of Operable Fms And Cps (Recommended)
Fm 8
Cp, Ptp 8
Cp, Lan 10
Rack
Racks, Max. 4
Modules Per Rack, Max. 8
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Backup Time 6 Wk; At 40 °C Ambient Temperature
Deviation Per Day, Max. 10 S; Typ.: 2 S
Behavior Of The Clock Following Power-On Clock Continues Running After Power Off
Behavior Of The Clock Following Expiry Of Backup Period The Clock Continues At The Time Of Day It Had When Power Was Switched Off
Operating Hours Counter
Number 1
Number/Number Range 0
Range Of Values 0 To 2^31 Hours (When Using Sfc 101)
Granularity 1 H
Retentive Yes; Must Be Restarted At Each Restart
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes; With Dp Slave Only Slave Clock
On Dp, Device Yes
In As, Master Yes
In As, Device No
Digital Inputs
Number Of Digital Inputs 0
Digital Outputs
Number Of Digital Outputs 0

Analog Inputs

Number Of Analog Inputs 0
Interfaces
Number Of Profinet Interfaces 0
Number Of Rs 485 Interfaces 2; Mpi And Profibus Dp
Number Of Rs 422 Interfaces 0
1. Interface
Interface Type Integrated Rs 485 Interface
Isolated No
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 200 Ma
Protocols
Mpi Yes
Profibus Dp Master No
Profibus Dp Device No
Point-To-Point Connection No
Mpi
Transmission Rate, Max. 187.5 Kbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes; Only Server, Configured On One Side
— S7 Communication, As Client No
— S7 Communication, As Server Yes
2. Interface
Interface Type Integrated Rs 485 Interface
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 200 Ma
Protocols
Mpi No
Profibus Dp Master Yes
Profibus Dp Device Yes
Point-To-Point Connection No
Profibus Dp Master
Number Of Connections, Max. 16
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 124; Per Station
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication Yes; I Blocks Only
— S7 Communication Yes; Only Server, Configured On One Side
— S7 Communication, As Client No
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes; Ob 61
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Max. Number Of Dp Devices That Can Be
Activated/Deactivated At The Same Time8
— Dpv1 Yes
Address Area
— Inputs, Max. 2 048 Byte
— Outputs, Max. 2 048 Byte
User Data Per Dp Device
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
2Nd Interface / Profibus Dp Device / Header
Gsd File The Latest Gsd File Is Available At: Http://Www.Siemens.Com/Profibus-Gsd
Transmission Rate, Max. 12 Mbit/S
Automatic Baud Rate Search Yes; Only With Passive Interface
Address Area, Max. 32
User Data Per Address Area, Max. 32 Byte
Services
— Pg/Op Communication Yes
— Routing Yes; Only With Active Interface
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client No
— S7 Communication, As Server Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
Protocols
Profisafe No
Communication Functions / Header
Pg/Op Communication Yes
Data Record Routing Yes
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 8
Number Of Gd Packets, Max. 8
Number Of Gd Packets, Transmitter, Max. 8
Number Of Gd Packets, Receiver, Max. 8
Size Of Gd Packets, Max. 22 Byte
Size Of Gd Packet (Of Which Consistent), Max. 22 Byte
S7 Basic Communication
Supported Yes
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 76 Byte; 76 Bytes (With X_Send Or X_Rcv); 64 Bytes (With X_Put Or X_Get
As Server)
S7 Communication
Supported Yes
As Server Yes
As Client Yes; Via Cp And Loadable Fb
User Data Per Job, Max. 180 Byte; With Put/Get
User Data Per Job (Of Which Consistent), Max. 240 Byte; As Server
S5 Compatible Communication
Supported Yes; Via Cp And Loadable Fc
Number Of Connections
Overall 16
Usable For Pg Communication 15
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Min. 1
— Adjustable For Pg Communication, Max. 15
Usable For Op Communication 15
— Reserved For Op Communication 1
— Adjustable For Op Communication, Min. 1
— Adjustable For Op Communication, Max. 15
Usable For S7 Basic Communication 12
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Min. 0
— Adjustable For S7 Basic Communication, Max. 12
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 16; Depending On The Configured Connections For Pg/Op And S7 Basic

Communication

Process Diagnostic Messages Yes
Simultaneously Active Alarm-S Blocks, Max. 300
Test Commissioning Functions
Status Block Yes; Up To 2 Simultaneously
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max. 30
— Of Which Status Variables, Max. 30
— Of Which Control Variables, Max. 14
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs
Number Of Variables, Max. 10
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 500
— Adjustable No
— Of Which Powerfail-Proof 100; Only The Last 100 Entries Are Retained
Number Of Entries Readable In Run, Max.
— Adjustable Yes; From 10 To 499
Preset 10
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes; File E239877
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Use In Hazardous Areas
Atex Yes

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax; 60 °C @ Ul/Cul, Atex And Fm Use
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Configuration / Header
Configuration Software
Step 7 Yes; V5.2 Sp1 Or Higher With Hw Update
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Know-How Protection
User Program Protection/Password Protection Yes

Dimensions

Width 40 Mm
Height 125 Mm
Depth 130 Mm
Weight S
Weight , Approx. 290 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible