Description for 6AG1321-1CH20-2AA0 Siemens

6AG1321-1CH20-2AA0 Siemens - SIPLUS S7-300 SM 321 based on 6ES7321-1CH20-0AA0 with conformal coating, -25…+70 °C, digital input isolated 16 DI, 48-125 V DC, 1x 20-pole

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£649.98 Exc. VAT
£779.98 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1321-1CH20-2AA0
Product Description SIPLUS S7-300 SM 321 based on 6ES7321-1CH20-0AA0 with conformal coating, -25…+70 °C, digital input isolated 16 DI, 48-125 V DC, 1x 20-pole
Product family SIPLUS S7-300 SM 321
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,251 Kg
Packaging Dimension 15,00 x 13,00 x 4,70
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515136170
UPC 662643198690
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 48 V
Permissible Range, Lower Limit (Dc) 48 V
Permissible Range, Upper Limit (Dc) 125 V
Input Current
From Backplane Bus 5 V Dc, Max. 40 Ma
Power Loss
Power Loss , Typ. 4.3 W
Digital Inputs
Number Of Digital Inputs 16
Input Characteristic Curve In Accordance With Iec 61131, Type 1 Yes
Number Of Simultaneously Controllable Inputs
All Mounting Positions
— Up To 60 °C, Max. 8; 6 @ Ue 146 V
— Up To 70 °C, Max. 6; 4 @ Ue 146 V
Horizontal Installation
— Up To 50 °C, Max. 8
— Up To 60 °C, Max. 8; 6 To Ue 146 V
Input Voltage
Type Of Input Voltage Dc
Rated Value (Dc) 48 V; 48 V Dc To 125 V Dc
For Signal "0" -146 V Dc To +15 V Dc
For Signal "1" 30 V Dc To 146 V Dc
Input Current
For Signal "1", Typ. 3.5 Ma
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable No
— At "0" To "1", Min. 0.1 Ms
— At "0" To "1", Max. 3.5 Ms
— At "1" To "0", Min. 0.7 Ms
— At "1" To "0", Max. 3 Ms
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Encoder
Connectable Encoders
2-Wire Sensor Yes
— Permissible Quiescent Current (2-Wire Sensor), Max. 1 Ma
Interrupts/Diagnostics/Status Information
Alarms No
Diagnostics Function No
Alarms
Diagnostic Alarm No
Hardware Interrupt No
Diagnostics Indication Led
Group Error Sf (Red) No
Status Indicator Digital Input (Green) Yes
Potential Separation
Potential Separation Digital Inputs
Between The Channels No
Between The Channels, In Groups Of 8
Between The Channels And Backplane Bus Yes; Optocoupler
Isolation
Isolation Tested With 1 500 V Dc
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes; File E239877
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Railway Application
En 50155 Yes; Sections 4, 5 And 12; No Further Agreements Apply; T1, Category 1, Class
A/B, En 50155:2007 (See Sios Entry 109755985)

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax; For Use On Railway Vehicles According To En50155, The Rated
Temperature Range -25 ... +55 °C (T1) Or 60 °C @ Ul/Ulhaz/Atex/Fm Use
Applies
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 50155 (St2); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En Yes; Class 6S3 Incl. Sand, Dust; *
60721-3-6
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 20-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 200 G