This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1322-1FH00-7AA0

6AG1322-1FH00-7AA0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1322-1FH00-7AA0 Siemens

6AG1322-1FH00-7AA0 Siemens - SIPLUS S7-300 SM 322 16DQ based on 6ES7322-1FH00-0AA0 with conformal coating, -40…+70 °C, digital output isolated 16 DQ, 120/230 V AC, 1 A, 1x 20-pole

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£809.82 Exc. VAT
£971.78 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1322-1FH00-7AA0
Product Description SIPLUS S7-300 SM 322 16DQ based on 6ES7322-1FH00-0AA0 with conformal coating, -40…+70 °C, digital output isolated 16 DQ, 120/230 V AC, 1 A, 1x 20-pole
Product family SIPLUS S7-300 SM 322
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,332 Kg
Packaging Dimension 15,00 x 13,00 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4042948494936
UPC 040892816273
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L1
Rated Value (Ac) 230 V; 120/230 V Ac
Permissible Range, Lower Limit (Ac) 79 V
Permissible Range, Upper Limit (Ac) 264 V
Input Current
From Load Voltage L1 (Without Load), Max. 2 Ma
From Backplane Bus 5 V Dc, Max. 200 Ma
Power Loss
Power Loss , Typ. 8.6 W
Digital Outputs
Number Of Digital Outputs 16
Short-Circuit Protection Yes; Fuse 8 A, 250 V; Per Group
Required Current For Fuse Shutdown, Min. 40 A
Response Time, Max. 300 Ms
Control Ling A Digital Input Yes
Size Of Motor Starters According To Nema, Max. 4 Nema Compliant
Spare Fuses 8 A / Quick Response
Switching Capacity Of The Outputs
On Lamp Load, Max. 50 W
Output Voltage
For Signal "1" (At Max. Current), Min. L1 (-1.5 V)
For Signal "1" (At Min. Current), Min. L1 (-8.5 V)
Output Current
For Signal "1" Rated Value 1 A
For Signal "1" Permissible Range For 0 To 40 °C, Min. 10 Ma
For Signal "1" Permissible Range For 0 To 40 °C, Max. 1 A
For Signal "1" Permissible Range For 40 To 60 °C, Min. 10 Ma
For Signal "1" Permissible Range For 40 To 60 °C, Max. 0.5 A
For Signal "1" Minimum Load Current 10 Ma
For Signal "1" Permissible Surge Current, Max. 20 A; With 2 Half Waves
For Signal "0" Residual Current, Max. 2 Ma
Parallel Switching Of Two Outputs
For Uprating No
For Redundant Control Of A Load Yes; Only Outputs Of The Same Group
Switching Frequency
With Resistive Load, Max. 10 Hz
With Inductive Load, Max. 0.5 Hz
With Inductive Load (Acc. To Iec 60947-5-1, Ac15), Max. 0.5 Hz
On Lamp Load, Max. 1 Hz
Total Current Of The Outputs (Per Group)
Horizontal Installation
— Up To 40 °C, Max. 4 A
— Up To 60 °C, Max. 2 A
— Up To 70 °C, Max. 1 A
Vertical Installation
— Up To 40 °C, Max. 2 A
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Fuse Blown Or Load Voltage Missing
Alarms
Diagnostic Alarm No
Diagnoses
Wire-Break No
Short-Circuit No
Fuse Blown Yes
Missing Load Voltage No
Diagnostics Indication Led
Rated Load Voltage Pwr (Green) No
Fuse Ok Fsg (Green) Yes; Red Led For Fuse
Group Error Sf (Red) Yes
Status Indicator Digital Output (Green) Yes
Potential Separation
Potential Separation Digital Outputs
Between The Channels, In Groups Of 8
Between The Channels And Backplane Bus Yes; Optocoupler
Isolation
Isolation Tested With 4 000 V Dc
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes; File E239877
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Railway Application
En 50121-4 No
En 50155 No

Ambient Temperature During Operation

Min. -40 °C; = Tmin
Max. 70 °C; = Tmax; 60 °C @ Ul/Cul, Atex And Fm Use
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
60721-3-3 Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 20-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 275 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible