Description for 6AG1322-8BF00-2AB0 Siemens

6AG1322-8BF00-2AB0 Siemens - SIPLUS S7-300 SM 322-20-pole based on 6ES7322-8BF00-0AB0 with conformal coating, -25…+60 °C,

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£823.07 Exc. VAT
£987.68 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1322-8BF00-2AB0
Product Description SIPLUS S7-300 SM 322-20-pole based on 6ES7322-8BF00-0AB0 with conformal coating, -25…+60 °C,
Product family SIPLUS S7-300 SM 322
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,249 Kg
Packaging Dimension 15,00 x 13,00 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515136248
UPC 662643198171
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
From Load Voltage L+ (Without Load), Max. 90 Ma
From Backplane Bus 5 V Dc, Max. 70 Ma
Power Loss
Power Loss , Typ. 5 W
Digital Outputs
Number Of Digital Outputs 8
Short-Circuit Protection Yes; Electronic
Response Threshold, Typ. 0.75 To 1.5 A
Limitation Of Inductive Shutdown Voltage To L+ (-45 V)
Control Ling A Digital Input Yes
Switching Capacity Of The Outputs
On Lamp Load, Max. 5 W
Load Resistance Range
Lower Limit 48 Ω
Upper Limit 3 Kω
Output Voltage
For Signal "1", Min. L+ (-0.8 To -1.6 V)
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "1" Permissible Range For 0 To 40 °C, Min. 10 Ma
For Signal "1" Permissible Range For 0 To 40 °C, Max. 0.6 A
For Signal "1" Permissible Range For 40 To 60 °C, Min. 10 Ma
For Signal "1" Permissible Range For 40 To 60 °C, Max. 0.6 A
For Signal "1" Minimum Load Current 10 Ma
For Signal "0" Residual Current, Max. 0.5 Ma
Output Delay With Resistive Load
"0" To "1", Max. 180 Μs
"1" To "0", Max. 245 Μs
Parallel Switching Of Two Outputs
For Uprating No
For Redundant Control Of A Load Outputs With Series Diodes Only
Switching Frequency
With Resistive Load, Max. 100 Hz
With Inductive Load, Max. 2 Hz
With Inductive Load (Acc. To Iec 60947-5-1, Dc13), Max. 2 Hz
On Lamp Load, Max. 10 Hz
Total Current Of The Outputs (Per Group)
Horizontal Installation
— Up To 40 °C, Max. 4 A
— Up To 60 °C, Max. 3 A
— Up To 70 °C, Max. 2.5 A; (Without Diode) & 1.5 A (With Diode)
Vertical Installation
— Up To 40 °C, Max. 4 A
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Diagnoses
Diagnostic Information Readable Yes
Wire-Break Yes
Short-Circuit Yes
Fuse Blown No
Missing Load Voltage Yes
Diagnostics Indication Led
Rated Load Voltage Pwr (Green) No
Fuse Ok Fsg (Green) No
Group Error Sf (Red) Yes
Status Indicator Digital Output (Green) Yes; Per Channel
Channel Fault Indicator F (Red) Yes
Potential Separation
Potential Separation Digital Outputs
Between The Channels, In Groups Of 8
Between The Channels And Backplane Bus Yes; Optocoupler
Isolation
Isolation Tested With 500 V Dc
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes; File E239877
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Railway Application
En 50155 Yes; Sections 4, 5 And 12; No Further Agreements Apply; T1, Category 1, Class
A/B, En 50155:2007 (See Sios Entry 109755985)

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax; 60 °C @ Ul/Cul Use
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 50155 (St2); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 20-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 210 G