This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1322-8BH10-7AB0

6AG1322-8BH10-7AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1322-8BH10-7AB0 Siemens

6AG1322-8BH10-7AB0 Siemens - SIPLUS S7-300 SM 322 16DA 24 V DC based on 6ES7322-8BH10-0AB0 with conformal coating, -25…+70 °C, digital output SM 322, 16 DQ; 24 V DC/0.5 A, diagnostics-capable, wire break detection with 0 and 1 signal, 1x 40-pole, connection IM 153-X HF required

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1322-8BH10-7AB0
Product Description SIPLUS S7-300 SM 322 16DA 24 V DC based on 6ES7322-8BH10-0AB0 with conformal coating, -25…+70 °C, digital output SM 322, 16 DQ; 24 V DC/0.5 A, diagnostics-capable, wire break detection with 0 and 1 signal, 1x 40-pole, connection IM 153-X HF required
Product family SIPLUS S7-300 SM 322
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,342 Kg
Packaging Dimension 15,00 x 13,00 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4042948612262
UPC 887621906634
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.09.2014
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
From Load Voltage L+ (Without Load), Max. 88 Ma
From Backplane Bus 5 V Dc, Max. 80 Ma
Power Loss
Power Loss , Typ. 5.7 W
Digital Outputs
Number Of Digital Outputs 16
Short-Circuit Protection Yes
Response Threshold, Typ. 1.4 A; Per Channel
Limitation Of Inductive Shutdown Voltage To L+ (-68 V)
Switching Capacity Of The Outputs
On Lamp Load, Max. 5 W
Load Resistance Range
Lower Limit 48 Ω
Upper Limit 4 Kω
Output Voltage
For Signal "1", Min. L+ (-0.7 V)
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "1" Permissible Range, Min. 5 Ma
For Signal "1" Permissible Range, Max. 0.6 A
For Signal "0" Residual Current, Max. 0.7 Ma
Output Delay With Resistive Load
"0" To "1", Max. 3 Ms
"1" To "0", Max. 3 Ms
Parallel Switching Of Two Outputs
For Uprating No
For Redundant Control Of A Load Yes
Switching Frequency
With Resistive Load, Max. 100 Hz
With Inductive Load (Acc. To Iec 60947-5-1, Dc13), Max. 2 Hz
On Lamp Load, Max. 10 Hz
Total Current Of The Outputs (Per Group)
Horizontal Installation
— Up To 60 °C, Max. 2 A
— Up To 70 °C, Max. 0.5 A
Vertical Installation
— Up To 40 °C, Max. 2 A
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Interrupts/Diagnostics/Status Information
Alarms Yes
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Diagnoses
Diagnostic Information Readable Yes
Wire-Break Yes
Short-Circuit Yes
Missing Load Voltage Yes
Diagnostics Indication Led
Rated Load Voltage Pwr (Green) No
Group Error Sf (Red) Yes
Status Indicator Digital Output (Green) Yes
Channel Fault Indicator F (Red) Yes
Potential Separation
Potential Separation Digital Outputs
Between The Channels No
Between The Channels, In Groups Of 4
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsno
Isolation
Isolation Tested With 500 V Dc
Standards, Approvals, Certificates
Ce Mark Yes

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax; @ 60°C For Ul/Atex/Fm Use
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 1X 40-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 350 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible