This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1326-1RF01-4AB0

6AG1326-1RF01-4AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1326-1RF01-4AB0 Siemens

6AG1326-1RF01-4AB0 Siemens - SIPLUS S7-300 SM 326F DI8 NAMUR based on 6ES7326-1RF01-0AB0 with conformal coating, 0…+60 °C, digital input SM 326, 8 DI; 24 V DC, NAMUR, fail-safe NAMUR input for SIMATIC S7 F-systems, up to category 4 (EN 954-1)/ SIL3 (IEC 61508)/PLE (ISO 13849), 1x 40-pole

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1326-1RF01-4AB0
Product Description SIPLUS S7-300 SM 326F DI8 NAMUR based on 6ES7326-1RF01-0AB0 with conformal coating, 0…+60 °C, digital input SM 326, 8 DI; 24 V DC, NAMUR, fail-safe NAMUR input for SIMATIC S7 F-systems, up to category 4 (EN 954-1)/ SIL3 (IEC 61508)/PLE (ISO 13849), 1x 40-pole
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 08.05.2024
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,560 Kg
Packaging Dimension 13,20 x 15,40 x 9,10
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618059101
UPC 195125290662
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4398
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 17.10.2014
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Input Current
From Load Voltage L+ (Without Load), Max. 160 Ma
From Backplane Bus 5 V Dc, Max. 90 Ma
Encoder Supply
Number Of Outputs 8
Type Of Output Voltage 8.2 V Dc
Power Loss
Power Loss , Typ. 4.5 W
Digital Inputs
Number Of Digital Inputs 8
Number Of Simultaneously Controllable Inputs
All Mounting Positions
— Up To 40 °C, Max. 8
— Up To 60 °C, Max. 8
Input Voltage
Type Of Input Voltage Dc
Input Current
For Signal "0", Max. (Permissible Quiescent Current) 0.35 To 1.2 Ma
For Signal "1", Typ. 2.1 To 7 Ma
Input Delay (For Rated Value Of Input Voltage)
For Namur Inputs
— At "0" To "1", Max. 1.2 To 3 Ms
— At "1" To "0", Max. 1.2 To 3 Ms
Cable Length
Shielded, Max. 200 M
Unshielded, Max. 100 M
Interrupts/Diagnostics/Status Information
Alarms
Diagnostic Alarm Yes; Parameterizable
Diagnostics Indication Led
Fail-Safe Operation Yes
Group Error Sf (Red) Yes
Ex(I) Characteristics
Module For Ex(I) Protection Yes
Maximum Values For Connecting Terminals For Gas Group Iic
Uo (No-Load Voltage), Max. 10 V
Io (Short-Circuit Current), Max. 13.9 Ma
Po (Power Output), Max. 33.1 Mw
Co (Permissible External Capacity), Max. 3 Μf
Lo (Permissible External Inductivity), Max. 80 Mh
Um (Voltage At Non-Intrinsically Safe Connecting
Terminals), Max.60 V Dc/30 V Ac
Potential Separation
Potential Separation Digital Inputs
Between The Channels Yes
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsyes
Standards, Approvals, Certificates
Ce Mark Yes
Highest Safety Class Achievable In Safety Mode
Acc. To En 954 Cat. 4
Performance Level According To Iso 13849-1 Ple
Sil Acc. To Iec 61508 Sil 2 (Single-Channel), Sil 3 (Two-Channel)

Ambient Temperature During Operation

Min. 0 °C; = Tmin
Max. 60 °C; = Tmax
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 1X 40-Pin

Dimensions

Width 80 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 482 G