Description for 6AG1331-7NF00-2AB0 Siemens

6AG1331-7NF00-2AB0 Siemens - SIPLUS S7-300 SM 331 40-pole based on 6ES7331-7NF00-0AB0 with conformal coating, -25…+70 °C, analog input isolated 8 AI; +/-5/10V, 1-5 V, +/-20 mA, 0/4 to 20 mA, 16 bit (55 ms), single rooting (50 V COM.)

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£1,243.95 Exc. VAT
£1,492.74 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1331-7NF00-2AB0
Product Description SIPLUS S7-300 SM 331 40-pole based on 6ES7331-7NF00-0AB0 with conformal coating, -25…+70 °C, analog input isolated 8 AI; +/-5/10V, 1-5 V, +/-20 mA, 0/4 to 20 mA, 16 bit (55 ms), single rooting (50 V COM.)
Product family SIPLUS S7-300 SM 331
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,316 Kg
Packaging Dimension 15,00 x 13,00 x 4,90
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515141310
UPC 662643199086
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Analog Inputs

Number Of Analog Inputs 8
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.50 V; Permanent
Permissible Input Current For Current Input (Destruction Limit),
Max.32 Ma
Input Ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance Thermometer No
Resistance No
Input Ranges (Rated Values), Voltages
0 To +10 V No
1 V To 5 V Yes
— Input Resistance (1 V To 5 V) 2 Mω
1 V To 10 V No
-1 V To +1 V No
-10 V To +10 V Yes
— Input Resistance (-10 V To +10 V) 2 Mω
-2.5 V To +2.5 V No
-250 Mv To +250 Mv No
-5 V To +5 V Yes
— Input Resistance (-5 V To +5 V) 2 Mω
-50 Mv To +50 Mv No
-500 Mv To +500 Mv No
-80 Mv To +80 Mv No
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 250 Ω
-20 Ma To +20 Ma Yes
— Input Resistance (-20 Ma To +20 Ma) 250 Ω
-3.2 Ma To +3.2 Ma No
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 250 Ω
Input Ranges (Rated Values), Thermocouples
Type B No
Type C No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type U No
Type Txk/Txk(L) To Gost No
Input Ranges (Rated Values), Resistance Thermometer
Cu 10 No
Ni 100 No
Ni 1000 No
Lg-Ni 1000 No
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 No
Pt 1000 No
Pt 200 No
Pt 500 No
Input Ranges (Rated Values), Resistors
0 To 150 Ohms No
0 To 300 Ohms No
0 To 600 Ohms No
0 To 6000 Ohms No
Cable Length
Shielded, Max. 200 M
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 16 Bit; Unipolar: 15/15/15/15 Bit; Bipolar: 15 Bit + Sign/15 Bit + Sign/15 Bit +
Sign/15 Bit + Sign
Integration Time, Parameterizable Yes; 10/ 16.67/ 20/ 100 Ms
Interference Voltage Suppression For Interference
Frequency F1 In Hz400 / 60 / 50 / 10 Hz
Encoder
Connection Of Signal Encoders
For Voltage Measurement Yes
For Current Measurement As 2-Wire Transducer Yes; With External Transmitter; Possible With Separate Supply For Transmitter
For Current Measurement As 4-Wire Transducer Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Input Range, (+/-) 0.1 %; @ Ucm = 0 V; @ Ucm = ±50 V: ±0.7 % - @ 0 ... +60 °C; ±0.5 % @ Ucm
= 0 V; @ Ucm = ±50 V: ±0.9 % - @ -25 ... +70 °C;
Current, Relative To Input Range, (+/-) 0.3 %; @ Ucm = 0 V; @ Ucm = ±50 V: ±0.4 % @ 0 ... +60 °C; ±0.5% @ Ucm =
0 V; @ Ucm = ±50 V: ±0.6% @ -25 ... +70 °C
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Input Range, (+/-) 0.05 %
Current, Relative To Input Range, (+/-) 0.05 %
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Limit Value Alarm Yes; Parameterizable, Channels 0 And 2
Diagnoses
Diagnostic Information Readable Yes
Diagnostics Indication Led
Group Error Sf (Red) Yes
Potential Separation
Potential Separation Analog Inputs
Between The Channels No
Between The Channels, In Groups Of 2
Between The Channels And Backplane Bus Yes
Isolation
Isolation Tested With 500 V Dc
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes; File E239877
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Railway Application
En 50155 Yes; Sections 4, 5 And 12; No Further Agreements Apply; T1, Category 1, Class
A/B, En 50155:2007 (See Sios Entry 109755985)

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax; For Use On Railway Vehicles According To En 50155, The Rated
Temperature Range -25 ... +55 °C (T1) Or 60 °C @ Ul/Ul Hazardous Use Applies
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 50155 (St2); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 40-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 117 Mm
Weight S
Weight , Approx. 272 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible